This is historical information of device classes implemented in APD_ACE device server.
Use this link to find the valid information.
Development status:
Released,
Release: release_1_0_5
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/APD_ACE
Contact:
Class Description
interface for the FMB-Oxford ACE processing unit for Avalanche Photo Diodes for use in X-Ray counting
Families: Acquisition
Key words: 1D
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| voltageScalar: DevDouble | — |
| voltageMonitorScalar: DevDouble | — |
| shapingTimeScalar: DevShort | — |
| scaLowerThresholdScalar: DevDouble | — |
| windowWidthScalar: DevDouble | — |
| scaUpperThresholdScalar: DevDouble | — |
| scaWindowCenterPositionScalar: DevDouble | — |
| temperatureScalar: DevDouble | — |
| currentScalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ExecLowLevelCommandInput: DevString Output: DevString |
None. |
| ModeWindowInput: DevVoid Output: DevVoid |
sets the APD ACE in mode Window ((mode used in SOLEIL) sends a to the controller |
| ResetInput: DevVoid Output: DevVoid |
reset the HW to the factory defaults |
| OffInput: DevVoid Output: DevVoid |
turns OFF the HW issues a HVOLT 1 then HVOLT OFF |
| OnInput: DevVoid Output: DevVoid |
turns the HW ON issues a HVOLT ON then HVOLT 200 then SCA WIN 10 10 |
Pipes:
Properties:
| Name | Description |
|---|---|
| UrlDevString | — |
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.