This is historical information of device classes implemented in Mythen2Detector device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/Mythen2Detector
Contact:
Class Description
Device for Mythen2 detectors from DECTRIS company. It connects to the Detector Control System (DCS4) which can manage four Mythen2 modules.
Families: Acquisition
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: DECTRIS
Bus: Data Socket
Class interface
Attributes:
| Name | Description |
|---|---|
| flatFieldCorrectionScalar: DevBoolean | Enables or disables the flatfield correction. |
| temperatureScalar: DevFloat | Returns the temperature of the SoC die on the DCS4 in degrees Celcius. |
| streamTypeScalar: DevString | Avalaible stream types :<br> NO_STREAM<br> LOG_STREAM <br> CSV_STREAM <br> NEXUS_STREAM<br> |
| streamTargetPathScalar: DevString | Defines the root path for generated Stream files. |
| nbModulesScalar: DevLong | DCS4 number of active modules |
| nbChannelsScalar: DevLong | DCS4 total number of channels of active modules |
| nbBadChannelsScalar: DevLong | DCS4 total number of bad channels of active modules |
| nbBitsScalar: DevULong | Number of bits to be read out,<br> thereby determining the dynamic range and the readout time.<br> Allowed values:<br> 4<br> 8<br> 16<br> 24<br> |
| triggerModeScalar: DevString | Set/Get current trigger mode<br> <br> Available Trigger Modes are : INTERNAL<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> EXTERNAL_GATE<br> |
| frameRateMaxScalar: DevFloat | Maximum allowed frame rate for the active detector modules. |
| nbFramesScalar: DevLong | Define the number of frames within an acquisition.<br> Available only with the Snap command.<br> With the Start command, it is always forced to 0, this is mean that we request an infinite number of frames. |
| currentFrameScalar: DevULong | Display the current frame number. Only relevant with the Snap command. |
| readoutTimeScalar: DevDouble | Get the readout time (in ms).<br> It depends of the current resolution (number of bits)<br> |
| exposureTimeScalar: DevDouble | Set/Get exposure time (in ms).<br> <br> Only relevant for these trigger modes :<br> NTERNAL<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| delayAfterFrameScalar: DevDouble | Set/Get the delay between two subsequent frames (in ms).<br> This is the delay between two exposures.<br> In the Mythen2 documentation, this data is called tafter or delafter.<br> <br> Only relevant for these trigger modes :<br> NTERNAL<br> EXTERNAL_SINGLE<br> |
| delayBeforeFrameScalar: DevDouble | Set/Get the delay between the trigger and the start of the exposure (in ms).<br> In the Mythen2 documentation, this data is called tbef or delbef.<br> <br> Only relevant for these trigger modes : EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| nbGatesByFrameScalar: DevULong | Number of gates within a frame.<br> <br> Only relevant for the trigger mode : EXTERNAL_GATE<br> |
| badChannelInterpolationScalar: DevBoolean | Turns on or off the interpolation routine for bad channels.<br> <br> When enabled, the number of counts for a bad channel is set to the average number of counts of the next lower and the next upper working channels.<br> <br> If there is no next lower (upper) working channel, the number of counts of the next upper (lower) working channel is used.<br> <br> When disabled the number of counts for a bad channel is set to -2. |
| streamTargetFileScalar: DevString | Define the file name for generated Stream files. |
| streamNbAcqPerFileScalar: DevULong | Define the number of acquisition for each Stream file. |
| rateCorrectionScalar: DevBoolean | Enables or disables the rate correction. After initialization, the rate correction is disabled. |
| flatfieldPathScalar: DevString | Defines the root path for generated flatfield files (.ftf). |
| flatfieldNameScalar: DevString | Shows the last loaded flatfield name. |
| frameSpectrum: DevLong | Last number of detected photons in each detector channel. |
| flatfieldSpectrum: DevLong | Shows the channel values of the current flatfield. Use the flatfield refresh command for an update of this spectrum. |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| SnapInput: DevVoid Output: DevVoid |
Arm/Start the acquisition. |
| StopInput: DevVoid Output: DevVoid |
Stop the acquisition. |
| StartInput: DevVoid Output: DevVoid |
Start the acquisition. |
| GetDataStreamsInput: DevVoid Output: DevVarStringArray |
Returns the flyscan data streams associated with this device formatted as below :<br> |
| StreamResetIndexInput: DevVoid Output: DevVoid |
Reset the stream (Nexus) buffer index to 1. |
| ResetDCS4Input: DevVoid Output: DevVoid |
Set the detector and its modules back to default settings. |
| CreateFlatfieldInput: DevVarStringArray flatfield alias;relative module number [1...module number] Output: DevVoid |
Create a flatfield file for a dcs module. |
| GetFlatfieldListInput: DevVoid Output: DevVarStringArray |
Display the list of available flatfield files. |
| ChooseFlatfieldInput: DevString Flatfield alias Output: DevVoid |
Load the flatfield into the dcs modules and activate it. |
| RefreshFlatfieldInput: DevVoid Output: DevVoid |
Refresh the current flatfield data shows in the device. |
Pipes:
Properties:
| Name | Description |
|---|---|
| DetectorHostDevString | IP address or fully qualified host name |
| DetectorPortDevLong | TCP connection port |
| MemorizedStreamTypeDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedStreamTargetPathDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedStreamTargetFileDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedStreamNbAcqPerFileDevULong | Only the device could modify this property <br> The User should never change this property<br> |
| ExpertStreamWriteModeDevString | Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - ASYNCHRONOUS<BR> - SYNCHRONOUS<BR> - DELAYED<BR> |
| StreamItemsArray of DevString | Define the list of Items managed by the Streamer. (Nexus, CSV, ...)<BR> Availables values are :<BR> Frame<BR> |
| SpoolIDDevString | Used only by the FlyScan application |
| MemorizedTriggerModeDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedNbFramesDevLong | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedExposureTimeDevDouble | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedDelayAfterFrameDevDouble | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedDelayBeforeFrameDevDouble | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedNbGatesByFrameDevULong | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedBadChannelInterpolationDevBoolean | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedFlatFieldCorrectionDevBoolean | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedEnergy01DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedEnergy02DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedEnergy03DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedEnergy04DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedThreshold01DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedThreshold02DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedThreshold03DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedThreshold04DevFloat | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedNbBitsDevULong | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedRateCorrectionDevBoolean | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedFlatfieldPathDevString | Only the device could modify this property <br> The User should never change this property<br> |
Updated:
The device class has been updated.
You can see previous version here .
7 Dec 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Dec 2017, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 Dec 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
4 Nov 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
15 Jul 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
1 Jul 2017, Piotr Goryl
Created:
The device class has been added to catalogue.