This is historical information of device classes implemented in VarianDUAL device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- This Device will manage the Varian DUAL Ion Pump Controller.
- It will read Pressure, Voltage and Current for each Channel and Firmware version and relays state. Last update: srubio@cells.es, 2007/09/20
Families: Vacuum
Key words:
Language: Python
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| V1Scalar: DevLong | — |
| V2Scalar: DevLong | — |
| I1Scalar: DevDouble | — |
| I2Scalar: DevDouble | — |
| P1Scalar: DevDouble | — |
| P2Scalar: DevDouble | — |
| InterlockScalar: DevBoolean | — |
| FirmwareVersionScalar: DevString | — |
| HV1StatusScalar: DevString | — |
| HV2StatusScalar: DevString | — |
Commands:
| Name | Description |
|---|---|
| OffInput: DevVoid Output: DevVoid |
It disables both high voltage outputs of the device |
| OnHV1Input: DevVoid Output: DevVoid |
It enables High Voltage Channel 1 |
| OnHV2Input: DevVoid Output: DevVoid |
It enables High Voltage Channel 2 |
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| SendCommandInput: DevVarCharArray Output: DevVarCharArray |
This command allows to send an array of characters directly to the device. |
| OnInput: DevVoid Output: DevVoid |
It enables both High Voltage Outputs of the device. |
| OffHV1Input: DevVoid Output: DevVoid |
It disables High Voltage Channel 1 |
| OffHV2Input: DevVoid Output: DevVoid |
It disables High Voltage Channel 2 |
Pipes:
Properties:
| Name | Description |
|---|---|
| SerialLineDevString | SerialLine Device Server to connect with |
| RefreshDevDouble | Period (in seconds) for the internal refresh thread. |
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:20 p.m.