Contact:



Class Description


controls the steerers, power supplies used for fast feedback
of closed orbit of electron beam steerers can be controlled by 2 ways : by this device server for slow or human control by Libera Beam Position monitors for fast control with closed loop control

Families: PowerSupply

Key words:

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
isLiberaControlledScalar: DevBoolean —
isOnScalar: DevBoolean —
currentScalar: DevDouble —
voltageScalar: DevDouble —
setpointScalar: DevDouble —
spMinScalar: DevDouble —
spMeanScalar: DevDouble —
spMaxScalar: DevDouble —
nbFrameSecScalar: DevUShort —
nbErrorSecScalar: DevUShort —
nbErrorCounterScalar: DevUShort —

Commands:

Name Description
SetLocalControlInput: DevVoid
Output: DevVoid
sets setpoint origin to the device : manual operation. you can set the power supply yourself
ClearErrorCounterInput: DevVoid
Output: DevVoid
clears the counter of total errors (attribute nbErrorCounter)
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
OnInput: DevVoid
Output: DevVoid
turns ON the power supply
OffInput: DevVoid
Output: DevVoid
turns OFF the power supply
ResetInput: DevVoid
Output: DevVoid
clears all errors of the BILT
ClearAlarmsInput: DevVoid
Output: DevVoid
clears alarms of the power supply
SetLiberaControlInput: DevVoid
Output: DevVoid
sets the setpoint origin to Libera the power supply will be controlled by the Libera BPM

Pipes:

Properties:

Name Description
IPAddressDevString IP Address of theBILT controller each controller includes 2 steerers each steerer includes 2 power supplies, 1 for horizontal correction (X axis) 1 for vertical correction (Z axis)
SteererNumberDevShort steerer number, from 1 to 48 see itest documentation
AxisLetterDevString must be X (horizontal correction) or Z (vertical correction)