Development status:
Released,
Release: Release_1_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/PiLCADCTriggerGenerator
Contact:
Class Description
Trigger generator using the PiLC
Families: OtherInstruments
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| NbExternalTriggersScalar: DevLong | Number of external triggers to generate |
| TriggerPulseLengthScalar: DevDouble | Length of the trigger pulse. Used in all trigger modes. It has to be smaller than the TimeTriggerStepSize (for trigger modes 2 and 3) and smaller than the time the motor needs for travelling the PositionTriggerStepSize for trigger modes (1 and 4). |
| ArmScalar: DevLong | Set to 1 for start triggering und to 0 to stop. |
| TimeTriggerStartScalar: DevDouble | Time delay before start triggering after arming (only used if triggermode 2 or 4) |
| TimeTriggerStepSizeScalar: DevDouble | Step size for triggers in time (only used if triggermode 2 or 3). |
| ADC1Scalar: DevDouble | — |
| FilePrefixScalar: DevString | File to save the data: FilePrefix.csv |
| FileDirScalar: DevString | Directory to save the data |
| ExternalTriggerCounterScalar: DevLong | Counter for the external triggers |
| RemainingTriggersScalar: DevDouble | — |
| BufferLoadScalar: DevDouble | Percentage of SDRAM buffer currently read |
| ADC2Scalar: DevDouble | — |
| ADC3Scalar: DevDouble | — |
| ADC4Scalar: DevDouble | — |
| ADC5Scalar: DevDouble | — |
| MaskDataToWriteScalar: DevLong | Mask for the writing of data, set to 1 the bit corresponding to the data you don`t want to be writen: counter 1, encoder1 2, encoder2 3, encoder3 4, encoder4 5, encoder5 6. Ex. not write encoder1 -> 2, not write encoder1 and encoder4 -> 18 |
| InternalTriggerCounterScalar: DevLong | Counter for the internal triggers for each external trigger |
| TriggerMultiplyScalar: DevLong | Number of internal triggers for each external trigger |
| ADC1DataSpectrum: DevDouble | — |
| ADC2DataSpectrum: DevDouble | — |
| ADC3DataSpectrum: DevDouble | — |
| ADC4DataSpectrum: DevDouble | — |
| ADC5DataSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
| Name | Description |
|---|---|
| PiLCDeviceDevString | Name of the PiLC tango device to connect to |
Please log in to comment.
Generated
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Created:
The device class has been added to catalogue.