NovelecElectrometer - - TANGO Controls

This is historical information of device classes implemented in NovelecElectrometer device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


This class allows you to control all MCCE-2 Novelec electrometers
through a Serial bus.
Supported types : Novelec Electrometers : MCCE2

Families: MeasureInstruments

Key words: - MCCE

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: SAPHYMO

Product:

MCCE-2

Bus: Serial Line

Class interface


Attributes:

Name Description
electrometerChannelScalar: DevUShort
range1Scalar: DevString
range2Scalar: DevString

Commands:

Name Description
LocalInput: DevVoid
Output: DevVoid
None.
RemoteInput: DevVoid
Output: DevVoid
None.
ResetInput: DevVoid
Output: DevVoid
None.
ClearRegistersInput: DevVoid
Output: DevVoid
None.
GetRangeInput: DevVoid
Output: DevString
None.
SetRangeInput: DevString
Output: DevVoid
None.
GetModeInput: DevVoid
Output: DevString
None.
GetPolarityInput: DevVoid
Output: DevString
None.
SetPolarityInput: DevString
Output: DevVoid
None.
GetHzFilterInput: DevVoid
Output: DevShort
None.
SetHzFilterInput: DevShort
Output: DevVoid
None.
GetGainInput: DevVoid
Output: DevShort
None.
SetGainInput: DevUShort
Output: DevVoid
None.
GetElectrometerTypeStrInput: DevUShort
Output: DevString
None.
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
RangeUPInput: DevVoid
Output: DevVoid
None.
RangeDOWNInput: DevVoid
Output: DevVoid
None.
SetZeroVFFunctionInput: DevVoid
Output: DevVoid
None.
SetOffsetZeroV1FunctionInput: DevVoid
Output: DevVoid
None.
SetLeakageZeroV2FunctionInput: DevVoid
Output: DevVoid
None.
SetTestFunctionInput: DevVoid
Output: DevVoid
None.
SetMeasureFunctionInput: DevVoid
Output: DevVoid
None.
MCCE2_ONInput: DevVoid
Output: DevVoid
None.
MCCE2_OFFInput: DevVoid
Output: DevVoid
None.

Pipes:

Properties:

Name Description
CommunicationLinkNameDevString The name of the device which manage the communication.
Electrometer1AddressDevShort The first electrometer address configured. Note : if not connected, push 0 or let empty the property.
Electrometer2AddressDevShort The second electrometer address configured. Note : if not connected, push 0 or let empty the property.

20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:11 p.m.