Class Description
- 2 modes (depending on properties):
- -Mode Retrig: Generate a single pulse on 8 counters each time a trigger is received. -Mode Continuous: Generate pulses continuously on 8 counters. The delay and the width of each pulse is configurable.
Families: CounterTimer
Key words: NI
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| generationTypeScalar: DevString | — |
| pulseNumberScalar: DevLong | — |
| counter0EnableScalar: DevBoolean | — |
| initialDelay0Scalar: DevDouble | — |
| delayCounter0Scalar: DevDouble | — |
| pulseWidthCounter0Scalar: DevDouble | — |
| counter1EnableScalar: DevBoolean | — |
| initialDelay1Scalar: DevDouble | — |
| delayCounter1Scalar: DevDouble | — |
| pulseWidthCounter1Scalar: DevDouble | — |
| counter2EnableScalar: DevBoolean | — |
| initialDelay2Scalar: DevDouble | — |
| delayCounter2Scalar: DevDouble | — |
| pulseWidthCounter2Scalar: DevDouble | — |
| counter3EnableScalar: DevBoolean | — |
| initialDelay3Scalar: DevDouble | — |
| delayCounter3Scalar: DevDouble | — |
| pulseWidthCounter3Scalar: DevDouble | — |
| counter4EnableScalar: DevBoolean | — |
| initialDelay4Scalar: DevDouble | — |
| delayCounter4Scalar: DevDouble | — |
| pulseWidthCounter4Scalar: DevDouble | — |
| counter5EnableScalar: DevBoolean | — |
| initialDelay5Scalar: DevDouble | — |
| delayCounter5Scalar: DevDouble | — |
| pulseWidthCounter5Scalar: DevDouble | — |
| counter6EnableScalar: DevBoolean | — |
| initialDelay6Scalar: DevDouble | — |
| delayCounter6Scalar: DevDouble | — |
| pulseWidthCounter6Scalar: DevDouble | — |
| counter7EnableScalar: DevBoolean | — |
| initialDelay7Scalar: DevDouble | — |
| delayCounter7Scalar: DevDouble | — |
| pulseWidthCounter7Scalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
Start generations of pulses. |
| StopInput: DevVoid Output: DevVoid |
Stop generations of pulses. |
| AbortInput: DevVoid Output: DevVoid |
Abort generations. |
| ResetBoardInput: DevVoid Output: DevVoid |
Reset the physical board. After this command, the board is in an unknown state (no more configured). The device must be initialized. |
| GetDriverVersionInput: DevVoid Output: DevString |
Get the current version of the driver installed for NI counter boards. |
| GetBoardsInChassisInput: DevVoid Output: DevString |
Get a string containing all the boards names (from NI) present in the chassis where this device is running. This names are defined in MAX. |
| GetBoardTypeInput: DevString Output: DevString |
Returns the type (ex: PXI-6602) of a specified board. |
Pipes:
Properties:
| Name | Description |
|---|---|
| TriggerSourceDevString | The name of the terminal for the input trigger as specified by NI (PFIxx). The trigger can be configured as following: - for finite and continuous modes, this trigger can be used as a start trigger (cf UseExtStartTrigger). If no start trigger is used, a counter of the board will be used to start all the other counters. - for retrig mode, each trigger will launch the generation of a pulses train. So the possible values are PFIxx |
| BoardNameDevString | The name of the board. |
| AutoStartDevBoolean | If true, the generation will start at device startup and when command ``Init`` is executed. |
| ClockDevString | The clock used. Possible values are ``INTERNAL`` or ``PFIxx``, with xx the pin number. |
| ExternalFrequencyDevDouble | In case of using an external clock, the frequency of this clock in Hz. |
| IdleStateCounter0DevString | cCan be LOW or HIGH. |
| IdleStateCounter1DevString | — |
| IdleStateCounter2DevString | — |
| IdleStateCounter3DevString | — |
| IdleStateCounter4DevString | — |
| IdleStateCounter5DevString | — |
| IdleStateCounter6DevString | — |
| IdleStateCounter7DevString | — |
| UseExtStartTriggerDevBoolean | If true, use the TriggerSource to start the generation in Finite or Continuous Mode. |
| TriggerEdgeDevString | values : POSITIVE or NEGATIVE. Set if the external trigger is posivite edge or negative edge. |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:08 p.m.