This is historical information of device classes implemented in AllenBradleyPLC device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- This class provides access to Rockwell Automation`s PLCs.
- It gives two ways of reading and setting values of tags. 1) by commands 2) by dynamic attributes (see Tags device property) Note! It depends on Tuxeip library.
Families: Communication
Key words:
Language: Cpp
Contact:
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| CloseInput: DevVoid Output: DevVoid |
Close connection to PLC |
| OpenInput: DevVoid Output: DevBoolean |
Open connection to PLC defined by properties |
| WriteTagsAsDoubleInput: DevVarDoubleStringArray Output: DevVarDoubleStringArray |
Writes tags, examining first types (by reading) in PLC and then doing proper conversion. |
| ReadTagsAsDoubleInput: DevVarStringArray Output: DevVarDoubleStringArray |
Reads the tag`s values from PLC and returns values and type |
| ReadTagInput: DevString Output: DevString |
Read tag value and return it as a string. |
| WriteTagInput: DevVarStringArray Output: DevString |
Write tag value specified by string. |
Pipes:
Properties:
| Name | Description |
|---|---|
| IPDevString | PLC IP number |
| PlcTypeDevString | PLC type |
| ConnectionIDDevLong | ID of the connection - for own use |
| ConnectionSNDevShort | Connection Serial Number - should be unique in the network |
| RPIDevLong | Request packet interval - used to calculate time-out |
| PathShort[]Type | Path to the device. See Tuxeip documentation. |
| AutoConnectDevBoolean | State if a device should try to reconnect to PLC if there is no connection, for an example in case of previous error... |
| TagUpdateIntervalDevLong | Min interval (in milliseconds) between update of tag`a value. |
| TagsString[]Type | List of tags in PLC. This list is used during device initiation to create attribs. It contains of lines of comma separated values: tagName,tagType,[attribName] tagName - is the name of tag in PLC, could contain array(structure) element selector in square bracket tagType - type of tag in PLC, should contain square bracket with size to determine array attribName - optionally attrib name to be mapped to tag attribName is required in case of tag pointing to element of structures or arrays in PLC |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:07 p.m.