Class Description
This class can be used to compute cristallography computation
Families: BeamlineComponents
Key words: Miscellaneous
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| AnglesIdxScalar: DevShort | — |
| AutoUpdateFromProxiesScalar: DevBoolean | — |
| WaveLengthScalar: DevDouble | — |
| CrystalScalar: DevString | — |
| AScalar: DevDouble | — |
| AFitScalar: DevBoolean | — |
| BScalar: DevDouble | — |
| BFitScalar: DevBoolean | — |
| CScalar: DevDouble | — |
| CFitScalar: DevBoolean | — |
| AlphaScalar: DevDouble | — |
| AlphaFitScalar: DevBoolean | — |
| BetaScalar: DevDouble | — |
| BetaFitScalar: DevBoolean | — |
| GammaScalar: DevDouble | — |
| GammaFitScalar: DevBoolean | — |
| UxScalar: DevDouble | — |
| UxFitScalar: DevBoolean | — |
| UyScalar: DevDouble | — |
| UyFitScalar: DevBoolean | — |
| UzScalar: DevDouble | — |
| UzFitScalar: DevBoolean | — |
| AStarScalar: DevDouble | — |
| BStarScalar: DevDouble | — |
| CStarScalar: DevDouble | — |
| AlphaStarScalar: DevDouble | — |
| BetaStarScalar: DevDouble | — |
| GammaStarScalar: DevDouble | — |
| SimulatedScalar: DevBoolean | — |
| CrystalNamesSpectrum: DevString | — |
| AxesNamesSpectrum: DevString | — |
| pseudoAxesProxiesSpectrum: DevString | — |
| AnglesImage: DevDouble | — |
| AnglesDegeneratedImage: DevBoolean | — |
| AnglesRangeCheckImage: DevBoolean | — |
| ReflectionsImage: DevDouble | — |
| ReflectionsAnglesImage: DevDouble | — |
| UBImage: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| AbortInput: DevVoid Output: DevVoid |
Stops the movement of all axis driven by the Diffractometer |
| AddNewCrystalInput: DevString Output: DevVoid |
Create a new crystal |
| AddReflectionInput: DevVarDoubleArray Output: DevVoid |
This commands requires the definition of 1 reflection defined by (h,k,l ) coordinates. This coodinates are associated with the current angles configuration. TODO: d�taill� le commentaire reflections i.e : h, k, l, relevance, enable/disable |
| AffineCrystalInput: DevString Output: DevDouble |
Compute affinement for the current crystal with available list of reflection. |
| ComputeUInput: DevVarLongArray Output: DevVoid |
Compute Matrix U from two reflections |
| ConfigureCrystalInput: DevVarDoubleArray Output: DevVoid |
Defines crystal lattice parameters. This information is mandatory for angles calculations. Angles units are degrees |
| CopyCurrentCrystalAsInput: DevString Output: DevVoid |
Copy the current crytal as another name |
| CopyReflectionToInput: DevVarDoubleStringArray Output: DevVoid |
Copy one reflection from the current crystal to another crystal |
| DeleteCurrentCrystalInput: DevVoid Output: DevVoid |
Delete the current from this device |
| GetCrystalParameterValuesInput: DevString Output: DevVarDoubleStringArray |
Return all values of a parameter for the current crystal |
| LoadInput: DevVoid Output: DevVoid |
Load all crystals |
| RemoveReflectionInput: DevShort Output: DevVoid |
This commands removes reflection from the current cristal. |
| SaveInput: DevVoid Output: DevVoid |
Save all crystals |
| SetCrystalParameterValuesInput: DevVarDoubleStringArray Output: DevVoid |
Double : min value, max value, affinement enable |
Pipes:
Properties:
| Name | Description |
|---|---|
| TauConstantDevDouble | Definition of the Tau constant . Possible values are pi or 1 . Default : 1 |
| RealAxisProxiesString[]Type | — |
| LambdaAttributeProxyDevString | The name of the lambda attribute proxy. The diffractometer use it to read the lambda value from another Device |
| DiffractometerTypeDevString | The Type of the diffractometer |
| ProtectReflectionAxesDevBoolean | allow or not to change the values of the axes in the Reflections attribute. set this properties to false to allow writting on the axes values. |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:05 p.m.