ScientaAcquisition - - TANGO Controls

This is historical information of device classes implemented in ScientaAcquisition device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Families: Acquisition

Key words: 2D

Platform: Windows

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Scienta

Product:

Scienta

Bus: Not Applicable

Class interface


Attributes:

Name Description
excitationEnergyScalar: DevDouble —
modeScalar: DevString —
highEnergyScalar: DevDouble —
lowEnergyScalar: DevDouble —
fixEnergyScalar: DevDouble —
energyStepScalar: DevDouble —
stepTimeScalar: DevDouble —
lensModeScalar: DevString —
passEnergyScalar: DevDouble —
passModeScalar: DevString —
detectorFirstXChannelScalar: DevShort —
detectorLastXChannelScalar: DevShort —
detectorFirstYChannelScalar: DevShort —
detectorLastYChannelScalar: DevShort —
detectorSlicesScalar: DevShort —
ADCModeScalar: DevShort —
ADCMaskScalar: DevShort —
discriminatorLevelScalar: DevShort —
channelsScalar: DevLong —
slicesScalar: DevLong —
sweepsScalar: DevLong —
spinFixed1Scalar: DevDouble —
spinFixed2Scalar: DevDouble —
spinFixed3Scalar: DevDouble —
spinFixed4Scalar: DevDouble —
areaScalar: DevDouble —
loadParametersAtStartScalar: DevBoolean —
channelScaleSpectrum: DevDouble —
sliceScaleSpectrum: DevDouble —
sumDataSpectrum: DevDouble —
spinSwept1Spectrum: DevDouble —
spinSwept2Spectrum: DevDouble —
spinSwept3Spectrum: DevDouble —
spinSwept4Spectrum: DevDouble —
dataImage: DevDouble —

Commands:

Name Description
ResetSuppliesInput: DevVoid
Output: DevVoid
Reset supplies.
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
Start the acqusition for one region with parameters configured in the attributes.
StopInput: DevVoid
Output: DevVoid
Stop the current acquisition.
ResetInstrumentInput: DevVoid
Output: DevVoid
Reset instrument.
TestCommunicationInput: DevVoid
Output: DevVoid
Test communication with hardware.
GetHardwareInfoInput: DevVoid
Output: DevString
Retrieve hardware informations.
GetLensModeListInput: DevVoid
Output: DevVarStringArray
None.
GetPassEnergyListInput: DevVoid
Output: DevVarDoubleArray
None.
GetPassModeListInput: DevVoid
Output: DevVarStringArray
None.
CalibrateInput: DevVoid
Output: DevVoid
Enter calibration mode (perform acquisition in an endless loop)
LoadParametersInput: DevVoid
Output: DevVoid
Send acquisition parameters to the detector

Pipes:

Properties:

Name Description
SesRootDirectoryDevString The ses root directory (where ses.exe is installed)
InstrumentFilePathDevString The name of the instrument file (eg:D:\\dev\\SES-1.2.5-rc6\\data\\Instrument.dat)
UseSpinDevBoolean if use or not spin

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:04 p.m.