This is historical information of device classes implemented in Prosilica device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| ExposureScalar: DevDouble | — |
| RoiSpectrum: DevLong | — |
| BinningSpectrum: DevShort | — |
| TriggerScalar: DevShort | — |
| WidthScalar: DevLong | — |
| HeightScalar: DevLong | — |
| DepthScalar: DevShort | — |
| FramesScalar: DevLong | — |
| ImageImage: DevUChar | — |
| ImageCounterScalar: DevLong | — |
| ImageFormatScalar: DevString | — |
| JpegImageSpectrum: DevUChar | — |
| JpegQualityScalar: DevShort | — |
| FileFormatScalar: DevString | — |
| FileParamsSpectrum: DevString | — |
| FullWidthScalar: DevLong | — |
| FullHeightScalar: DevLong | — |
| JpegCompressionScalar: DevBoolean | — |
| BayerImageSpectrum: DevUChar | — |
| GainScalar: DevLong | — |
| ShortImageImage: DevShort | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| LiveInput: DevVoid Output: DevVoid |
Start camera in live acquisition mode. |
| StopInput: DevVoid Output: DevVoid |
stop the live acquisition mode |
| ResetInput: DevVoid Output: DevVoid |
reset ROI, binning and scaling to the full image values |
| WriteFileInput: DevVoid Output: DevVoid |
write image to file in the selected format, use the file parameters to generate file name |
| TGradientInput: DevShort Output: DevLong |
This command makes an estimation about the focalization of the camera. The calculation is done on the current image. |
| StartInput: DevVoid Output: DevVoid |
Take a single image frame and do the necessary calculation on the acquired image. After the command is executed the image and the results can be read. |
| SnapInput: DevVoid Output: DevVoid |
Trigger the camera by software |
Pipes:
Properties:
| Name | Description |
|---|---|
| IpDevString | Identifies Prosilica camera |
| Init_binningDevShort | Initial binning (both for X and Y) |
| Fixed_frame_rateDevLong | Frames per second |
| Jumbo_framesDevBoolean | Define if it is posible to use Jumbo Frames. |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:04 p.m.