This is historical information of device classes implemented in ImgGrabber device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| CurrentlySavingMovieScalar: DevBoolean | — |
| MovieRemainingTimeScalar: DevString | — |
| ImageImage: DevUShort | — |
Commands:
| Name | Description |
|---|---|
| ResetROIInput: DevVoid Output: DevVoid |
None. |
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| OpenInput: DevVoid Output: DevVoid |
None. |
| CloseInput: DevVoid Output: DevVoid |
None. |
| StartInput: DevVoid Output: DevVoid |
None. |
| StopInput: DevVoid Output: DevVoid |
None. |
| StartSaveMovieInput: DevVarDoubleStringArray Output: DevVoid |
saves a movie in the directory specified in the MoviePath property, and with the format specified as MovieFormat. |
| StopSaveMovieInput: DevVoid Output: DevVoid |
immediately stops the movie saving |
| SnapInput: DevVoid Output: DevVoid |
None. |
| SetROIInput: DevVarLongArray Output: DevVoid |
None. |
| GetROIInput: DevVoid Output: DevVarLongArray |
None. |
| SaveSettingsInput: DevVoid Output: DevVoid |
save the current acquisition parameters to the device Properties |
| GetPluginInfoInput: DevVoid Output: DevString |
Retrieves information about the grabber plugin used |
| ResetCameraInput: DevVoid Output: DevVoid |
None. |
Pipes:
Properties:
| Name | Description |
|---|---|
| PluginLocationDevString | the full path to the ImgGrabber plugin |
| MoviePathDevString | the path where the movie/images are recorded |
| MovieFormatDevString | the format of the saved files : JPG, PNG, TIF, PGM, BMP, DIB, RAS |
| AutoStartDevBoolean | automatically start grabbing at init |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:03 p.m.