This is historical information of device classes implemented in Ieee1394 device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- A generic device server for interfacing all FireWire cameras under Linux. It uses
- the dc1394 library for accessing the cameras.
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| InfoScalar: DevString | — |
| ExposureScalar: DevDouble | — |
| RoiSpectrum: DevLong | — |
| BinningSpectrum: DevShort | — |
| WidthScalar: DevLong | — |
| HeightScalar: DevLong | — |
| FramesScalar: DevLong | — |
| DepthScalar: DevShort | — |
| FileParamsSpectrum: DevString | — |
| FileFormatScalar: DevString | — |
| VideoModeScalar: DevShort | — |
| VideoModeTagScalar: DevString | — |
| VideoModesSupportedSpectrum: DevString | — |
| BayerMethodScalar: DevShort | — |
| FrameRateScalar: DevDouble | — |
| ImageImage: DevUChar | — |
| ImageFormatScalar: DevString | — |
| ImageCounterScalar: DevLong | — |
| JpegImageSpectrum: DevUChar | — |
| JpegQualityScalar: DevShort | — |
| JpegCompressionScalar: DevBoolean | — |
| AutoFeaturesScalar: DevBoolean | — |
| RelativeUnitsScalar: DevBoolean | — |
| BrightnessScalar: DevDouble | — |
| SharpnessScalar: DevDouble | — |
| WhiteBalanceScalar: DevDouble | — |
| HueScalar: DevDouble | — |
| SaturationScalar: DevDouble | — |
| GammaScalar: DevDouble | — |
| GainScalar: DevDouble | — |
| IrisScalar: DevDouble | — |
| FocusScalar: DevDouble | — |
| TemperatureScalar: DevDouble | — |
| TriggerDelayScalar: DevDouble | — |
| WhiteShadingScalar: DevDouble | — |
| TriggerScalar: DevShort | — |
| TriggerModeScalar: DevShort | — |
| TriggerPolarityScalar: DevShort | — |
| TriggerSourceScalar: DevShort | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
start camera exposing |
| StopInput: DevVoid Output: DevVoid |
stop camera exposing |
| ResetInput: DevVoid Output: DevVoid |
reset camera roi |
| WriteFileInput: DevVoid Output: DevVoid |
write image to file in the selected format, use the file parameters to generate file name |
| LiveInput: DevVoid Output: DevVoid |
put camera in live mode |
Pipes:
Properties:
| Name | Description |
|---|---|
| Camera_numberDevLong | number of camera on the ieee1394 bus (starting from 0 |
| Camera_id_lowDevLong | unique ieee1394 camera id - low 32 bits |
| Camera_id_highDevLong | Unique ieee1394 camera id - high 32 bits |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:03 p.m.