This is historical information of device classes implemented in HdbConfiguratorServer device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/SoftwareSystem/HdbConfiguratorServer
Contact:



Class Description


This class is able to use HdbConfigurator classes to Add/Start/Stop archiving attributes on HDB++ subscribers. It uses call on HdbConfiguratorServer device.

Families: System

Key words: Archiving,Archiving,Archiving,Archiving,Archiving,Archiving,Archiving,Archiving,Archiving,Archiving

Platform: All Platforms

Language: Java

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
HdbManagerDeviceNameScalar: DevString Returns the manager device name
ArchiverListSpectrum: DevString Managed archiver list
ArchiverAliasListSpectrum: DevString Managed archiver alias list

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
AddAttributesInput: DevVarStringArray
[0] - Subscriber name. [1] - Attribute 1 name. [2] - Attribute 2 name. - - - - - [n] - Attribute n name. [n+1] - true/false for using push event (false if not specified)
Output: DevLong
ID number. Usefull to get information later.
Add specified attributes to the specified subscriber attribute list if not already done and start archiving. Due to a possible dead lock, during this command execution and the event subscribing, this subscription will delayed and done by a thread. To avoid a bottle neck for this command execution, the subscriptions will be serialized. That means that it could takes several seconds. Use AddingState and AddingStatus commands to know if subscriptions are done without problem.
AddingStateInput: DevLong
ID returns by AddAttributes command
Output: State
ON if adding has been done. ALARM if at least one have failed. MOVING if adding is not finished.
Returns the AddingAttributes command state.
AddingStatusInput: DevLong
ID returns by AddAttributes command
Output: DevString
Return AddAttributes command error message if any.
Returns the AddingAttributes command status.
AttributeIsManagedInput: DevString
Attribute name
Output: DevBoolean
true if attribute managed. False otherwise.
Check if the specified attribute is managed by a subscriber. If not, use AddAttributes command to set it managed.
AttributeStartedInput: DevString
Specified attribute name.
Output: DevBoolean
true if archiving is started
Check if attribute archiving is started
AttributePausedInput: DevString
Specified attribute name.
Output: DevBoolean
true if archiving is paused
Check if attribute archiving is paused
AttributeStoppedInput: DevString
Specified attribute name.
Output: DevBoolean
true if archiving is stopped
Check if attribute archiving is stopped
AttributeGetArchiverInput: DevString
Specified attriute name.
Output: DevString
The subscriber name.
Returns the subscriber name for specified attribute.
AttributeGetArchiverAliasInput: DevString
Specified attriute alias.
Output: DevString
The subscriber name.
Returns the subscriber alias for specified attribute.
StartArchivingInput: DevVarStringArray
Attribute names to be started.
Output: DevVoid
Start archiving for specified attributes.
StopArchivingInput: DevVarStringArray
Attribute names to be stopped.
Output: DevVoid
Stop archiving for specified attributes.
RemoveAttributesInput: DevVarStringArray
Attribute list to be removed
Output: DevVoid
Stop archiving if necessary and remove attributes from subscriber list

Pipes:

Properties:

Name Description
HdbManagerDevString The HDB++ manager device name (HdbConfiguratorServer class). This property is mandatory
WaitingTimeDevLong Waiting time before trying to add attributes to HDB++ in seconds

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 11:19 a.m.