Class Description
Class for controlling the Power Supply of Delta Elektronka SM 70-22.
Families: PowerSupply
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Delta Elektronika
Product:
SM70-22
Bus: Ethernet
Class interface
Attributes:
| Name | Description |
|---|---|
| ModelInfoScalar: DevString | — |
| SetCurrentScalar: DevFloat | Nominal current value. |
| SetVoltageScalar: DevFloat | Nominal voltage value. |
| MeasCurrentScalar: DevFloat | Measured current. |
| MeasVoltageScalar: DevFloat | Measured voltage. |
| MaximumCurrentScalar: DevFloat | Maximum current |
| MaximumVoltageScalar: DevFloat | Maximum voltage |
| Cal0Scalar: DevFloat | — |
| Cal1Scalar: DevFloat | — |
| Cal2Scalar: DevFloat | — |
| Cal3Scalar: DevFloat | — |
| Cal4Scalar: DevFloat | — |
| Cal5Scalar: DevFloat | — |
| Cal6Scalar: DevFloat | — |
| Cal7Scalar: DevFloat | — |
| OutpScalar: DevLong | 0 -> off, 1 -> on |
| RemScalar: DevLong | 0->rem,1->loc |
| RemCCScalar: DevLong | 0->rem,1->loc |
| RemCVScalar: DevLong | 0->rem,1->loc |
| ErrorScalar: DevString | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ResetInput: DevVoid Output: DevVoid |
Reset power supply. |
| SaveInput: DevVoid Output: DevVoid |
Save configuration. |
| WriteReadSocketInput: DevString Output: DevString |
Write to the socket and get answer. |
| WriteSocketInput: DevString Output: DevVoid |
Write command to the socket without getting an answer. |
Pipes:
Properties:
| Name | Description |
|---|---|
| PortNbDevLong | Port Number for connecting to the power supply |
| HostnameDevString | Hostname of the power supply. |
| SimulationModeDevULong | 0 -> real mode, 1 -> simulation mode |
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.