This is historical information of device classes implemented in Vibrations device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/Vibrations
Contact:
Class Description
Class computing vibrations in Petra Hall.
Families: Miscellaneous
Key words:
Platform: Unix Like
Language: Python
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| DeviceScalar: DevString | — |
| DataTypeScalar: DevString | — |
| SampleRateScalar: DevFloat | — |
| TimeOffsetScalar: DevFloat | — |
| OversamplingScalar: DevFloat | — |
| AmpGainScalar: DevFloat | — |
| VTransmissionScalar: DevFloat | — |
| MinFreqScalar: DevFloat | — |
| DeviceTypeScalar: DevString | — |
| MaxFreqScalar: DevFloat | — |
| NDataPointsScalar: DevLong | — |
| TSampleScalar: DevFloat | — |
| NDataPointsSampleScalar: DevLong | — |
| NAverageScalar: DevFloat | — |
| VMeanScalar: DevFloat | — |
| VStdScalar: DevFloat | — |
| RMS1HzScalar: DevDouble | — |
| RMS2HzScalar: DevDouble | — |
| RMS5HzScalar: DevDouble | — |
| RMS10HzScalar: DevDouble | — |
| RMS20HzScalar: DevDouble | — |
| RMS50HzScalar: DevDouble | — |
| TimeAverageScalar: DevDouble | — |
| SumPSDsScalar: DevDouble | — |
| MaxSigScalar: DevDouble | — |
| MinSigScalar: DevDouble | — |
| Time0Scalar: DevString | — |
| LocalTimeScalar: DevString | — |
| CurrentFileNameScalar: DevString | — |
| TimeAxisSpectrum: DevDouble | — |
| FrequenciesSpectrum: DevDouble | — |
| FrequenciesSampleSpectrum: DevDouble | — |
| SSpectrum: DevDouble | — |
| VSpectrum: DevDouble | — |
| ASpectrum: DevDouble | — |
| FftSSpectrum: DevDouble | — |
| FftVSpectrum: DevDouble | — |
| FftASpectrum: DevDouble | — |
| PSDSSpectrum: DevDouble | — |
| PSDVSpectrum: DevDouble | — |
| PSDASpectrum: DevDouble | — |
| RMSSSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
Pipes:
Properties:
| Name | Description |
|---|---|
| FilesPathDevString | Path to the directory containing the data from Device. |
| DeviceDirectionDevString | Identify the direction of the device in the room: nord (S1n), east (S1e) or z (S1z). |
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.