Development status:
Released,
Release: latest
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Keithley/Keithley428
Contact:
Class Description
Class for controlling the Keithley428 current amplifier.
Families: Instrumentation
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Keithley
Product:
428
Bus: GPIB
Class interface
Attributes:
| Name | Description |
|---|---|
| GainScalar: DevLong | 0, 1, 2, 3 -> 10e3 V/A\n4 -> 10e4 V/A\n5 -> 10e5 V/A\n6 -> 10e6 V/A\n7 -> 10e7 V/A\n8 -> 10e8 V/A\n9 -> 10e9 V/A\n10 -> 10e10 V/A\n11 -> 10e11 V/A |
| GainStrScalar: DevString | — |
| OverloadedScalar: DevLong | 1 if device is overloaded |
| BypassScalar: DevLong | 0 -> zero check off, 1 -> zero check on, 2 (only read) zero correction last selected. |
| filterStateScalar: DevString | State of the manual filter |
| autoFilterStateScalar: DevString | State of the auto Filter |
| RiseTimeScalar: DevLong | 0 -> 10e-6 sec\n1 -> 30e-6 sec\n2 -> 100e-6 sec\n3 -> 300e-6 sec\n4 -> 1e-3 sec\n5 -> 3e-3 sec\n6 -> 10e-3 sec\n7 -> 30e-3 sec\n8 -> 100e-3 sec\n9 -> 300e-3 sec\n |
| RiseTimeStrScalar: DevString | 0 -> 10e-6 sec\n1 -> 30e-6 sec\n2 -> 100e-6 sec\n3 -> 300e-6 sec\n4 -> 1e-3 sec\n5 -> 3e-3 sec\n6 -> 10e-3 sec\n7 -> 30e-3 sec\n8 -> 100e-3 sec\n9 -> 300e-3 sec\n |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| PerformZeroCorrectInput: DevVoid Output: DevVoid |
Perform Zero correction. |
| FilterOnInput: DevVoid Output: DevVoid |
Turn the filter ON |
| FilterOffInput: DevVoid Output: DevVoid |
Turn the filter OFF |
| AutoFilterOnInput: DevVoid Output: DevVoid |
Enable Auto Filter |
| AutoFilterOffInput: DevVoid Output: DevVoid |
Disable Auto Filter |
Pipes:
Properties:
| Name | Description |
|---|---|
| GpibDeviceDevString | Name of the gpib device connected to the hardware. |
| GpibDeviceIdDevShort | Gpib device ID if this is to be used with a prologix network adapter. |
Please log in to comment.
Generated
Updated:
The device class has been updated.
You can see previous version here .
27 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.