This is historical information of device classes implemented in PhaseRetarderP09 device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Motion/PhaseRetarderP09
Contact:
Class Description
Class for controlling the motors of the double phase retarder at p09.
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| PositionScalar: DevDouble | — |
| PRZSScalar: DevDouble | — |
| PRCHIScalar: DevDouble | — |
| PRTHScalar: DevDouble | — |
| D111Scalar: DevDouble | — |
| Offset111Scalar: DevDouble | — |
| AngleNormal111Scalar: DevDouble | — |
| SignScalar: DevLong | — |
| AmplitudeScalar: DevDouble | — |
| WplrScalar: DevFloat | Either -3., -2., -1, -0.5,, 0, +0.5, +1, + 2 or +3. |
| DthChiScalar: DevDouble | — |
| UnitLimitMinScalar: DevDouble | — |
| UnitLimitMaxScalar: DevDouble | — |
| PositionSimScalar: DevDouble | — |
| PathConfigFilesScalar: DevString | Path to config files. |
| ConfigFileScalar: DevString | Config file name to be load with reset command. |
| PRZSLoadedScalar: DevDouble | — |
| PRCHILoadedScalar: DevDouble | — |
| DthChiA0Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| DthChiA1Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| DthChiA2Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| DthChiA3Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| DthChiA4Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| DthChiA5Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| DthChiA6Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| DthChiA7Scalar: DevDouble | Parameter for computing DthChi from PrChi motor position. |
| ResultSimSpectrum: DevString | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| StopMoveInput: DevVoid Output: DevVoid |
— |
| ShowContentsConfigFileInput: DevVoid Output: DevVarStringArray |
Reads the contents of the configuration file given in the ConfigFile attribute. |
| MoveToLoadedPositionsInput: DevVoid Output: DevVoid |
Move PRZS and PRCHI motors to loaded positions. |
| LoadFileInput: DevVoid Output: DevVoid |
Set attribute values to the defaults in the configuration file. |
Pipes:
Properties:
| Name | Description |
|---|---|
| PRZSMotorDeviceDevString | Tango device name of the PRZS motor. |
| PRCHIMotorDeviceDevString | Tango device name of the PRCHI motor. |
| PRTHMotorDeviceDevString | Tango device name of the PRTH motor. |
| FlagDthchiFromPrchiDevLong | If 1 dthchi will be computed from Prchi |
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.