Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Tektronix/TekDPO7000-ds
Contact:
Class Description
Device server designed to control the tektronix`s oscilloscopes model DPO7254
Families: MeasureInstruments
Key words: Tektronix
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| HOffsetScalar: DevShort | — |
| HScaleScalar: DevDouble | — |
| DelayScalar: DevShort | — |
| ImpedanceCh1Scalar: DevDouble | — |
| CurrentSampleRateScalar: DevDouble | — |
| VScaleCh1Scalar: DevDouble | — |
| VScaleCh2Scalar: DevDouble | — |
| VScaleCh3Scalar: DevDouble | — |
| VScaleCh4Scalar: DevDouble | — |
| ImpedanceCh2Scalar: DevDouble | — |
| ImpedanceCh3Scalar: DevDouble | — |
| ImpedanceCh4Scalar: DevDouble | — |
| ResolutionScalar: DevLong | — |
| AmplitudeCh1Scalar: DevDouble | — |
| AmplitudeCh2Scalar: DevDouble | — |
| AmplitudeCh3Scalar: DevDouble | — |
| AmplitudeCh4Scalar: DevDouble | — |
| RiseCh1Scalar: DevDouble | — |
| RiseCh2Scalar: DevDouble | — |
| RiseCh3Scalar: DevDouble | — |
| RiseCh4Scalar: DevDouble | — |
| JitRMSCh1Scalar: DevDouble | — |
| JitRMSCh2Scalar: DevDouble | — |
| JitRMSCh3Scalar: DevDouble | — |
| JitRMSCh4Scalar: DevDouble | — |
| VOffsetCh1Scalar: DevDouble | — |
| VOffsetCh2Scalar: DevDouble | — |
| VOffsetCh3Scalar: DevDouble | — |
| VOffsetCh4Scalar: DevDouble | — |
| VOffsetSpectrum: DevDouble | — |
| VScaleSpectrum: DevDouble | — |
| Channel1Spectrum: DevDouble | — |
| Channel2Spectrum: DevDouble | — |
| Channel3Spectrum: DevDouble | — |
| Channel4Spectrum: DevDouble | — |
| ImpedancesSpectrum: DevDouble | — |
| ChannelsImage: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ResetInput: DevVoid Output: DevVoid |
None. |
| StartInput: DevVoid Output: DevVoid |
None. |
| StopInput: DevVoid Output: DevVoid |
None. |
| IDNInput: DevVoid Output: DevString |
Basic command used to validate the comunication. It send the `*IDN?` command-string to the (remote) instrument, and the instrument respond basic data about itself. |
| CMDInput: DevString Output: DevString |
This command sends the input string as a command to the device, and it returns the string that the device returns. |
| OnInput: DevShort Output: DevVoid |
None. |
| OffInput: DevShort Output: DevVoid |
None. |
Pipes:
Properties:
| Name | Description |
|---|---|
| NumChannelsDevShort | This information is used to generate dinamically the number of spaces will be in much of the spectrum values. |
| IPDevString | — |
Please log in to comment.
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.