This is historical information of device classes implemented in PicoScaleCtrl device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/PicoScaleCtrl
Contact:
Class Description
Controller device class for SmarAct Picoscale Interferometer
Families: Instrumentation
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: http://www.smaract.de/
Product:
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| FileDirScalar: DevString | The directory data files will be saved in |
| FilePrefixScalar: DevString | The directory data files will be saved in |
| FileStartNumScalar: DevLong | — |
| FilePostfixScalar: DevString | The file name extension of your data files. A dot between filename and extension will be added. |
| FileSavingScalar: DevBoolean | Whether to save files true: files will be written false: files will not be written |
| FullAccessScalar: DevBoolean | Whether we have a full access connection true: full access false: limited access |
| SystemStateScalar: DevBoolean | — |
| FrameRateScalar: DevLong | — |
| MaxFrameRateScalar: DevLong | — |
| FrameAggregationScalar: DevLong | — |
| DeviceIdScalar: DevString | — |
| TriggerScalar: DevBoolean | — |
| TriggerFramesScalar: DevLong | Number of data frames to send in triggered data acquisition mode once the trigger line goes up. |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ChannelInfoInput: DevLong axis number Output: DevVarLongArray |
— |
| EnableStreamingInput: DevVarLongArray axis number, data source number Output: DevVoid |
— |
| StreamingEnabledInput: DevVarLongArray axis number, data source number Output: DevBoolean |
— |
| StreamableInput: DevVarLongArray axis number, data source number Output: DevBoolean |
— |
| GetValueInput: DevVarLongArray channel index, source index Output: DevDouble value |
— |
| ChannelEnabledInput: DevLong channel number Output: DevBoolean true: enabled false: disables |
— |
| EnableChannelInput: DevVarLongArray channel number, enable = 1/disable=0 Output: DevVoid |
Enable or disable channel |
| CollectDataStartInput: DevVoid Output: DevVoid |
Start data streaming |
| CollectDataStopInput: DevVoid Output: DevVoid |
Stop data streaming |
| CollectDataTimeInput: DevULong time to stream in milliseconds Output: DevVoid |
Start data streaming for a specified time |
| SourceNameInput: DevLong datasource type Output: DevString name for this type of data source |
— |
| GetPropertValue32Input: DevLong property key Output: DevLong value |
Gets the value for a i32 property |
| SetPropertValue32Input: DevVarLongArray 0: property key 1: value Output: DevVoid |
Sets the value for a i32 property |
Pipes:
Properties:
| Name | Description |
|---|---|
| HostNameDevString | Hostname / IP address of controller |
| PortNumberDevUShort | Port number of controller |
| MemBufferSizeDevULong | Amount of memory assigned for stream data buffering |
Updated:
The device class has been updated.
You can see previous version here .
27 May 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.