This is historical information of device classes implemented in Keithley6517a device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Keithley/Keithley6517a
Contact:
Class Description
Class for controlling the Keithley6517a electrometer
Families: Instrumentation
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Keithley
Product:
6517a
Bus: GPIB
Class interface
Attributes:
| Name | Description |
|---|---|
| CurrentScalar: DevDouble | Measured current |
| RangeScalar: DevDouble | — |
| MeasurementFunctionScalar: DevString | Set/get measurement function. Valid values: VOLT, CURR, RES, CHAR |
| VoltIntegrationPeriodScalar: DevDouble | Integration period for voltage measurements. |
| CurrIntegrationPeriodScalar: DevDouble | Integration period for current measurements. |
| CharIntegrationPeriodScalar: DevDouble | Integration period for charge measurements. |
| VoltRangeScalar: DevDouble | Measurement range for Volts |
| CurrRangeScalar: DevDouble | Measurement range for Amps |
| CharRangeScalar: DevDouble | Measurement range for Coulombs |
| VSourceScalar: DevDouble | V-Source level for manual V-source Ohms. |
| ResIntegrationPeriodScalar: DevDouble | Integration period for resistance measurements. |
| VSourceOffOnScalar: DevLong | Enable/disable (1/0) V-Source level for manual V-source Ohms. |
| CurrAutoRangeScalar: DevLong | 1 -> ON, 0 -> OFF |
| VoltAutoRangeScalar: DevLong | 1 -> ON, 0 -> OFF |
| CharAutoRangeScalar: DevLong | 1 -> ON, 0 -> OFF |
| CurrRange20mAScalar: DevLong | 1 if current range 20 mA |
| CurrRange2mAScalar: DevLong | 1 if current range 2 mA |
| CurrRange200microAScalar: DevLong | 1 if current range 200 microA |
| CurrRange20microAScalar: DevLong | 1 if current range 20 microA |
| CurrRange2microAScalar: DevLong | 1 if current range 2 microA |
| CurrRange200nAScalar: DevLong | 1 if current range 200 nA |
| CurrRange20nAScalar: DevLong | 1 if current range 20 nA |
| CurrRange2nAScalar: DevLong | 1 if current range 2 nA |
| CurrRange200pAScalar: DevLong | 1 if current range 200 pA |
| CurrRange20pAScalar: DevLong | 1 if current range 20 pA |
| ZeroCheckScalar: DevLong | 0 -> off, 1 -> on |
| CurrentWithTimestampSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| ResetTimestampInput: DevVoid Output: DevVoid |
Reset timestamp to 0 |
Pipes:
Properties:
| Name | Description |
|---|---|
| GpibDeviceDevString | Name of the gpib device connected to the hardware. |
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.