Class Description
Class for controlling the vacuum pressure measurement and control devices from Pfeiffer.
Families: Vacuum
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: Pfeiffer
Product:
TPG262 and TPG256A
Bus: Data Socket
Class interface
Attributes:
Name | Description |
---|---|
PressureSensor1Scalar: DevDouble | — |
PressureSensor2Scalar: DevDouble | — |
PressureUnitsScalar: DevString | — |
SetPoint1Scalar: DevString | Status (0 -> off, 1->on), min value, max value |
SetPoint2Scalar: DevString | Status (0 -> off, 1->on), min value, max value |
SetPoint3Scalar: DevString | Status (0 -> off, 1->on), min value, max value |
SetPoint4Scalar: DevString | Status (0 -> off, 1->on), min value, max value |
SensorStatus1Scalar: DevString | Sensor Status: Ok = Messdaten okay Ur = Messbereichsunterschreitung (Underrange) Or = Messbereichsüberschreitung (Overrange) SenErr = Messstellenfehler (Sensor-Error) Off = Messstelle ausgeschaltet None = keine Messröhre IdErr = Identifikationsfehler Ukn = Unknown, still not tried to readout |
SensorStatus2Scalar: DevString | Sensor Status: Ok = Messdaten okay Ur = Messbereichsunterschreitung (Underrange) Or = Messbereichsüberschreitung (Overrange) SenErr = Messstellenfehler (Sensor-Error) Off = Messstelle ausgeschaltet None = keine Messröhre IdErr = Identifikationsfehler Ukn = Unknown, still not tried to readout |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
WriteReadRawInput: DevString Message to send Output: DevString Raw answer |
Sends a command to the device and returns the answer. |
Pipes:
Properties:
Name | Description |
---|---|
PortNbDevLong | Port number |
SimulationModeDevLong | 0-> no simulation |
HostNameDevString | Name of the terminal server connecting to the device |
TPGTypeDevLong | Type of TPG device device: 262, 256 |
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.