This is historical information of device classes implemented in Mythen2Detector device server.

Use this link to find the valid information.

Development status: Released, Release: release_1_1_0
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/Mythen2Detector
Contact:



Class Description


Device for Mythen2 detectors from DECTRIS company. It connects to the Detector Control System (DCS4) which can manage four Mythen2 modules.

Families: Acquisition

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: DECTRIS

Bus: Data Socket

Class interface


Attributes:

Name Description
nbModulesScalar: DevLong DCS4 number of active modules
nbChannelsScalar: DevLong DCS4 total number of channels of active modules
nbBadChannelsScalar: DevLong DCS4 total number of bad channels of active modules
nbBitsScalar: DevULong Number of bits to be read out,<br> thereby determining the dynamic range and the readout time.<br> Allowed values:<br> 4<br> 8<br> 16<br> 24<br>
triggerModeScalar: DevString Set/Get current trigger mode<br> <br> Available Trigger Modes are : INTERNAL<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> EXTERNAL_GATE<br>
frameRateMaxScalar: DevFloat Maximum allowed frame rate for the active detector modules.
nbFramesScalar: DevLong Define the number of frames within an acquisition.<br> Available only with the Snap command.<br> With the Start command, it is always forced to 0, this is mean that we request an infinite number of frames.
currentFrameScalar: DevULong Display the current frame number. Only relevant with the Snap command.
readoutTimeScalar: DevDouble Get the readout time (in ms).<br> It depends of the current resolution (number of bits)<br>
exposureTimeScalar: DevDouble Set/Get exposure time (in ms).<br> <br> Only relevant for these trigger modes :<br> NTERNAL<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br>
delayAfterFrameScalar: DevDouble Set/Get the delay between two subsequent frames (in ms).<br> This is the delay between two exposures.<br> In the Mythen2 documentation, this data is called tafter or delafter.<br> <br> Only relevant for these trigger modes :<br> NTERNAL<br> EXTERNAL_SINGLE<br>
delayBeforeFrameScalar: DevDouble Set/Get the delay between the trigger and the start of the exposure (in ms).<br> In the Mythen2 documentation, this data is called tbef or delbef.<br> <br> Only relevant for these trigger modes : EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br>
nbGatesByFrameScalar: DevULong Number of gates within a frame.<br> <br> Only relevant for the trigger mode : EXTERNAL_GATE<br>
badChannelInterpolationScalar: DevBoolean Turns on or off the interpolation routine for bad channels.<br> <br> When enabled, the number of counts for a bad channel is set to the average number of counts of the next lower and the next upper working channels.<br> <br> If there is no next lower (upper) working channel, the number of counts of the next upper (lower) working channel is used.<br> <br> When disabled the number of counts for a bad channel is set to -2.
flatFieldCorrectionScalar: DevBoolean Enables or disables the flatfield correction.
temperatureScalar: DevFloat Returns the temperature of the SoC die on the DCS4 in degrees Celcius.
streamTypeScalar: DevString Avalaible stream types :<br> NO_STREAM<br> LOG_STREAM <br> CSV_STREAM <br> NEXUS_STREAM<br>
streamTargetPathScalar: DevString Defines the root path for generated Stream files.
streamTargetFileScalar: DevString Define the file name for generated Stream files.
streamNbAcqPerFileScalar: DevULong Define the number of acquisition for each Stream file.
rateCorrectionScalar: DevBoolean Enables or disables the rate correction. After initialization, the rate correction is disabled.
flatfieldPathScalar: DevString Defines the root path for generated flatfield files (.ftf).
flatfieldNameScalar: DevString Shows the last loaded flatfield name.
fileGenerationScalar: DevBoolean File generation after a start/snap command
frameSpectrum: DevLong Last number of detected photons in each detector channel.
flatfieldSpectrum: DevLong Shows the channel values of the current flatfield. Use the flatfield refresh command for an update of this spectrum.

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
SnapInput: DevVoid
Output: DevVoid
Arm/Start the acquisition.
StopInput: DevVoid
Output: DevVoid
Stop the acquisition.
StartInput: DevVoid
Output: DevVoid
Start the acquisition.
GetDataStreamsInput: DevVoid
Output: DevVarStringArray
Returns the flyscan data streams associated with this device formatted as below :<br>
StreamResetIndexInput: DevVoid
Output: DevVoid
Reset the stream (Nexus) buffer index to 1.
ResetDCS4Input: DevVoid
Output: DevVoid
Set the detector and its modules back to default settings.
CreateFlatfieldInput: DevVarStringArray
flatfield alias;relative module number [1...module number]
Output: DevVoid
Create a flatfield file for a dcs module.
GetFlatfieldListInput: DevVoid
Output: DevVarStringArray
Display the list of available flatfield files.
ChooseFlatfieldInput: DevString
Flatfield alias
Output: DevVoid
Load the flatfield into the dcs modules and activate it.
RefreshFlatfieldInput: DevVoid
Output: DevVoid
Refresh the current flatfield data shows in the device.

Pipes:

Properties:

Name Description
DetectorHostDevString IP address or fully qualified host name
DetectorPortDevLong TCP connection port
MemorizedStreamTypeDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedStreamTargetPathDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedStreamTargetFileDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedStreamNbAcqPerFileDevULong Only the device could modify this property <br> The User should never change this property<br>
ExpertStreamWriteModeDevString Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - ASYNCHRONOUS<BR> - SYNCHRONOUS<BR> - DELAYED<BR>
StreamItemsArray of DevString Define the list of Items managed by the Streamer. (Nexus, CSV, ...)<BR> Availables values are :<BR> Frame<BR>
SpoolIDDevString Used only by the FlyScan application
MemorizedTriggerModeDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedNbFramesDevLong Only the device could modify this property <br> The User should never change this property<br>
MemorizedExposureTimeDevDouble Only the device could modify this property <br> The User should never change this property<br>
MemorizedDelayAfterFrameDevDouble Only the device could modify this property <br> The User should never change this property<br>
MemorizedDelayBeforeFrameDevDouble Only the device could modify this property <br> The User should never change this property<br>
MemorizedNbGatesByFrameDevULong Only the device could modify this property <br> The User should never change this property<br>
MemorizedBadChannelInterpolationDevBoolean Only the device could modify this property <br> The User should never change this property<br>
MemorizedFlatFieldCorrectionDevBoolean Only the device could modify this property <br> The User should never change this property<br>
MemorizedEnergy01DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedEnergy02DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedEnergy03DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedEnergy04DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedThreshold01DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedThreshold02DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedThreshold03DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedThreshold04DevFloat Only the device could modify this property <br> The User should never change this property<br>
MemorizedNbBitsDevULong Only the device could modify this property <br> The User should never change this property<br>
MemorizedRateCorrectionDevBoolean Only the device could modify this property <br> The User should never change this property<br>
MemorizedFlatfieldPathDevString Only the device could modify this property <br> The User should never change this property<br>

19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Dec 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Dec 2017, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Dec 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



4 Nov 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



15 Jul 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



1 Jul 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:2 Dec 2017, 3 a.m.