Class Description


The Bilt multi channel power supply has three individual channels. This class offers an interface to an individual channel of the power supply.

Families: Miscellaneous

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: itest

Product:

Bilt Module BE548

Bus: Tango

Class interface


Attributes:

Name Description
CurrentScalar: DevDouble The DC current of the selected pole.
VoltageScalar: DevDouble The measured voltage of the selected pole.
ImpedanceScalar: DevDouble Calculated impedance of the selected pole.
SetCurrentRMSScalar: DevDouble Statistic when driven by the Libera.\nRMS value of the AC setpoint applied on the DAC during the last second.\nX=sqr( (sum(setAC)*sum(setAC)) / n - ((sum(setAC)/n) *(sum(setAC)/n)) )
SetCurrentAverageScalar: DevDouble Statistic when driven by the Libera.\nThe average AC setpoint applied to the DAC during the last second.\nX=SUM(setAC)/n
FramesPerSecondScalar: DevULong Statistic when driven by the Libera.\nThe number of setpoints per second.
ErrorPerSecondScalar: DevULong Statistic when driven by the Libera.\nThe number of errors detected per second.
ErrorCounterScalar: DevULong Statistic when driven by the Libera.\nThe total number of errors since the last reset.
LocalControlScalar: DevBoolean If true the AC current can be set on the device,\notherwise it is driven by the Libera.
SetCurrentACScalar: DevDouble The AC current setpoint in local mode. If driven by the Libera, the attribute \nattribute value in INVALID.
Temperature1Scalar: DevDouble Temperature 1 of the pole.
Temperature2Scalar: DevDouble Temperature 2 of the pole.

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
OnInput: DevVoid
Output: DevVoid
Switch ON all three channels of the Bilt power supply
OffInput: DevVoid
Output: DevVoid
Switch Off all three channels of the Bilt power supply
ResetInput: DevVoid
Output: DevVoid
Send a reset to the Bilt power supply

Pipes:

Properties:

Name Description
BiltNameDevString Name of the Bilt multi channel power supply device
PoleNumberDevShort The number of the channel or Pole of the Bilt power supply [0 -2]

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:51 a.m.