This is historical information of device classes implemented in TDKLambdaGenesys device server.

Use this link to find the valid information.

Development status: New development
Information status: New
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/PowerSupply/TDKLambdaGenesys
Contact:



Class Description


Control of the Genesys power supply from TDKLamda

Families: PowerSupply

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: TDK-Lambda Americas Inc.

Product:

Genesys

Bus: Socket

Class interface


Attributes:

Name Description
VoltageSetpointScalar: DevDouble Reads/Sets the output voltage setting
VoltageScalar: DevDouble Reads the actual output voltage
CurrentSetpointScalar: DevDouble Reads/Sets the output current setting
CurrentScalar: DevDouble Reads the actual output current

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
WriteReadCmdInput: DevString
Command to send
Output: DevString
Answer from device
Sends a command string and returns the answer

Pipes:

Properties:

Name Description
IpAddressDevString Ip address of the terminal server the controller is connected to
PortNbDevLong Port number the controller is connected to
DeviceAddressDevLong Address of the device (only one is allowed)

13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



10 Nov 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:13 Nov 2021, 4:22 a.m.