Class Description


Control of the p04 monochromator interfacing to EPICS.

Families: Motion

Key words:

Platform: Unix Like

Language: Python

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
PositionScalar: DevDouble Monochromator energy.
UnitLimitMaxScalar: DevDouble
UnitLimitMinScalar: DevDouble
CffScalar: DevDouble Cff value
MirrorNameScalar: DevString Type of mirror and surface
GratingNameScalar: DevString Lines per mm and depth of ruling
OrderScalar: DevDouble Diffraction order
EnergyMeanScalar: DevDouble Moving average of monochromator energy

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
CalibrateInput: DevDouble
Value to set the current position.
Output: DevVoid
ResetMotorInput: DevVoid
Output: DevVoid
Enables all motor axes
StopMoveInput: DevVoid
Output: DevVoid

Pipes:

Properties:

Name Description
BranchDevLong 1 for monochromator HASPP04PMPGU1 2 for monochromator HASPP04PMPGU2

9 Oct 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 May 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Sep 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:9 Oct 2021, 3:16 a.m.