This is historical information of device classes implemented in CenterThreeCtrl device server.

Use this link to find the valid information.

Development status: Released, Release: Release_1_8
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/SampleEnvironment/CenterThreeCtrl
Contact:



Class Description


Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Ethernet

Class interface


Attributes:

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
WriteReadCmdInput: DevString
Command to send to the controller
Output: DevString
Controller reply
Send command to the controller with reply exspected
ReadCmdInput: DevVoid
Output: DevString
Readout string
Read from device. Used one the device send string without asking. (mode set with command COM).

Pipes:

Properties:

Name Description
PortNumberDevString Port number
SimulationModeDevLong
HostNameDevString Hostname or IP Address
NrChannelsDevLong Max. Number of channels
ConnectTypeDevString `net` or `serial`
DeviceFileDevString tty device file
BaudRateDevLong rs232 baud rate
TalkContinouslyDevBoolean If set to true, the server will send a COM to the controller at server start (making the controller send measurement data continuously). Set this to true, if you use this controller device with the CenterThreeCOM class. Otherwise leave it at false.
TalkContinouslyRateDevLong Time interval of the controller sending measurement data if TalkContinously is set to true. 0: 100 milliseconds 1: one second (default) 2: 1 minute

5 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Nov 2021, DS Admin
Updated:
A device class has been added.
You can see previous version here .



6 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:4 Sep 2021, 4:22 a.m.