Class Description
A Class to handle the modbus protocol over TCP/IP or Serial (RTU).
Families: Communication
Key words:
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Modbus
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| ForceSingleCoilInput: DevVarShortArray coil address, 0/1 Output: DevVoid |
Write single coil (digital I/O) state. |
| ReadCoilStatusInput: DevShort coil address Output: DevShort Coil status |
Read coil (digital I/O) status. |
| ReadInputStatusInput: DevVarShortArray input address, no. of inputs Output: DevVarCharArray Input status. |
Read discrete input status. Return one boolean per array element. |
| ReadHoldingRegistersInput: DevVarShortArray register address, no. of registers Output: DevVarShortArray Holding 16bits register. |
Read multiple 16bits registers. |
| ReadInputRegistersInput: DevVarShortArray register address, no. of registers Output: DevVarShortArray Input 16bits registers |
Read Multiple 16bits input registers. |
| PresetSingleRegisterInput: DevVarShortArray Register address, register value. Output: DevVoid |
Write single 16bits register. |
| ReadExceptionStatusInput: DevVoid Output: DevShort exception status |
Read exception status (usually a predefined range of 8 bits |
| FetchCommEventCtrInput: DevVoid Output: DevVarShortArray status, event count |
Fetch communications event counter. |
| ForceMultipleCoilsInput: DevVarShortArray coil address, nb of coils, coil states Output: DevVoid |
Write multiple coils (digital I/O) state. argin[0] = coil_address argin[1] = number of coils argin[2] = 1st coil state argin[3] = 2nd coil state ... |
| ReadMultipleCoilsStatusInput: DevVarShortArray coil address, nb of coils Output: DevVarShortArray Status of coils |
Read multiple coil (digital I/O) status. argin[0] = register address argin[1] = number of registers |
| PresetMultipleRegistersInput: DevVarShortArray register address, nb of registers, register data Output: DevVoid |
Write multiple 16bits registers. argin[0] = register address argin[1] = number of registers argin[2] = 1st register argin[3] = 2nd register ... |
| MaskWriteRegisterInput: DevVarShortArray register address, AND mask, OR mask Output: DevVoid |
Mask write a 16bits register. |
| ReadWriteRegisterInput: DevVarShortArray read address, no. to read, write address, nb.of write, write data Output: DevVarShortArray read registers |
Read and Write multiple 16bits registers. argin[0] = read address argin[1] = nb of registers to read argin[2] = write address, argin[3] = nb of registers to write, argin[4] = 1st register value to write argin[5] = 2nd register value to write ... |
| PresetSingleRegisterBroadcastInput: DevVarShortArray register value. Output: DevVoid |
Write single 16bits register at address 0 (Address reserved for broadcast) Does not wait for the equipment response. |
Pipes:
Properties:
| Name | Description |
|---|---|
| ProtocolDevString | RTU`` : Binary serial communication. ``TCP`` : Communication over ethernet. |
| IphostDevString | The host IP address used with the TCP protocol in the form aa.bb.cc.dd. |
| SeriallineDevString | The name of the serial line device used with RTU protocol. This can be any device name of a Serial Class object in the Tango system. |
| AddressDevShort | Node index used with the RTU or TCP protocol |
| CacheConfigArray of DevString | Describe which data has to be cached. Each set of cached data is described by 3 parameters which are: 1 - Command to be used to read data (ReadHoldingRegisters, ReadInputStatus ReadInutRegisters or ReadMultipleCoilStatus) 2 - First address to be read 3 - Number of data to read |
| CacheSleepDevLong | Cache update thread main loop sleeping time (in ms) |
| SocketConnectionSleepDevLong | The necessary sleep time between closing a connection (Socket) and opening a new connection. To avoid hang-ups a non blocking socket is used to check the availability on the network. Afterwards the non blocking socket is closed and a blocking socket will be opened. The SocketConnectionSleep time specified the wait time in ms between these two connections. |
| TCPTimeoutDevDouble | Timeout used when the TCP protocol is used (in sec) |
| LogFileDevString | Name og the file where are stored invalid frame |
| TCPNoDelayDevBoolean | Disable Nagle`s algorithm. Set this property to reduce the latency of TCP transmissions. This property is relevant only if the ``Protocol`` property is set to ``TCP``. |
| TCPQuickAckDevBoolean | Set this property to true to enable TCP quick acknowledgements to reduce the TCP latency. This could be useful with some electronic boards to force the device server to acknowledge immediately the received TCP packets. This avoids TCP packets retransmissions and reduces the TCP latency. Please note that this is relevant only if ``Protocol`` property is set to ``TCP``. Please also note that this works only on Linux Operating Systems. |
Updated:
The device class has been updated.
You can see previous version here .
29 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Jun 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.