Class Description


The device analyzes images accessible on another remote device,
and proposes the following (selectable) features : - in preprocessing : rotation, mirroring, gamma correction - ROI (Region Of Interest), either user-defined or automatic by blob analysis - image moments (mean intensity, centroid, variance, skew) - maximal intensity (to monitor saturation for example) - ellipse fitting when automatic ROI is desired - profiles with corresponding gaussian fit - 2D gaussian fit of the image

Families: Calculation

Key words:

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
EnableImageStatsScalar: DevBoolean —
EnableProfilesScalar: DevBoolean —
EnableHistogramScalar: DevBoolean —
EnableUserROIScalar: DevBoolean —
EnableAutoROIScalar: DevBoolean —
Enable2DGaussianFitScalar: DevBoolean —
ComputationPeriodScalar: DevLong —
EstimComputTimeScalar: DevLong —
RotationScalar: DevLong —
HorizontalFlipScalar: DevBoolean —
BitsPerPixelScalar: DevLong —
HistogramNbBinsScalar: DevLong —
HistogramRangeMinScalar: DevLong —
HistogramRangeMaxScalar: DevLong —
GammaCorrectionScalar: DevDouble —
AutoROIMagFactorXScalar: DevDouble —
AutoROIMagFactorYScalar: DevDouble —
AutoROIThresholdScalar: DevLong —
BgSubstractionScalar: DevDouble —
AlarmZoneScalar: DevLong —
PixelSizeXScalar: DevDouble —
PixelSizeYScalar: DevDouble —
OpticalMagnificationScalar: DevDouble —
ProfileFitFixedBgScalar: DevBoolean —
LineProfileOriginXScalar: DevLong —
LineProfileOriginYScalar: DevLong —
LineProfileEndXScalar: DevLong —
LineProfileEndYScalar: DevLong —
LineProfileThicknessScalar: DevLong —
ChamberOffsetXScalar: DevDouble —
ChamberOffsetYScalar: DevDouble —
ChamberCentroidXScalar: DevDouble —
ChamberCentroidYScalar: DevDouble —
ChamberXProjFitCenterScalar: DevDouble —
ChamberYProjFitCenterScalar: DevDouble —
UserROIOriginXScalar: DevLong —
UserROIOriginYScalar: DevLong —
UserROIWidthScalar: DevLong —
UserROIHeightScalar: DevLong —
AutoROIFoundScalar: DevBoolean —
AutoROIOriginXScalar: DevLong —
AutoROIOriginYScalar: DevLong —
AutoROIWidthScalar: DevLong —
AutoROIHeightScalar: DevLong —
MaxIntensityScalar: DevDouble —
MeanIntensityScalar: DevDouble —
CentroidXScalar: DevDouble —
CentroidYScalar: DevDouble —
CentroidSaturatedScalar: DevBoolean —
CentroidSaturationRegionSideScalar: DevLong —
CentroidSaturationRegionThresholdScalar: DevLong —
VarianceXScalar: DevDouble —
VarianceYScalar: DevDouble —
CovarianceXYScalar: DevDouble —
CorrelationXYScalar: DevDouble —
SkewXScalar: DevDouble —
SkewYScalar: DevDouble —
SkewX2YScalar: DevDouble —
SkewXY2Scalar: DevDouble —
XProjFitConvergedScalar: DevBoolean —
XProjFitCenterScalar: DevDouble —
XProjFitMagScalar: DevDouble —
XProjFitSigmaScalar: DevDouble —
XProjFitFWHMScalar: DevDouble —
XProjFitBGScalar: DevDouble —
XProjFitChi2Scalar: DevDouble —
YProjFitConvergedScalar: DevBoolean —
YProjFitCenterScalar: DevDouble —
YProjFitMagScalar: DevDouble —
YProjFitSigmaScalar: DevDouble —
YProjFitFWHMScalar: DevDouble —
YProjFitBGScalar: DevDouble —
YProjFitChi2Scalar: DevDouble —
LineProfileFitConvergedScalar: DevBoolean —
LineProfileFitCenterScalar: DevDouble —
LineProfileFitMagScalar: DevDouble —
LineProfileFitSigmaScalar: DevDouble —
LineProfileFitFWHMScalar: DevDouble —
LineProfileFitBGScalar: DevDouble —
LineProfileFitChi2Scalar: DevDouble —
GaussianFitConvergedScalar: DevBoolean —
GaussianFitMagnitudeScalar: DevDouble —
GaussianFitCenterXScalar: DevDouble —
GaussianFitCenterYScalar: DevDouble —
GaussianFitVarianceXScalar: DevDouble —
GaussianFitVarianceYScalar: DevDouble —
GaussianFitCovarianceXYScalar: DevDouble —
GaussianFitMajorAxisFWHMScalar: DevDouble —
GaussianFitMinorAxisFWHMScalar: DevDouble —
GaussianFitTiltScalar: DevDouble —
GaussianFitBGScalar: DevDouble —
GaussianFitChi2Scalar: DevDouble —
Fit1DNbIterMaxScalar: DevLong —
Fit1DMaxRelChangeScalar: DevDouble —
Fit2DNbIterMaxScalar: DevLong —
Fit2DMaxRelChangeScalar: DevDouble —
XProjFitNbIterScalar: DevLong —
XProjFitRelChangeScalar: DevDouble —
YProjFitNbIterScalar: DevLong —
YProjFitRelChangeScalar: DevDouble —
LineProfileFitNbIterScalar: DevLong —
LineProfileFitRelChangeScalar: DevDouble —
GaussianFitNbIterScalar: DevLong —
GaussianFitRelChangeScalar: DevDouble —
RmsXScalar: DevDouble —
RmsYScalar: DevDouble —
SumImagePixelsScalar: DevDouble —
XProjSpectrum: DevDouble —
XProjFittedSpectrum: DevDouble —
XProjErrorSpectrum: DevDouble —
YProjSpectrum: DevDouble —
YProjFittedSpectrum: DevDouble —
YProjErrorSpectrum: DevDouble —
LineProfileSpectrum: DevDouble —
LineProfileFittedSpectrum: DevDouble —
LineProfileErrorSpectrum: DevDouble —
HistogramSpectrum: DevFloat —
InputImageImage: DevULong —
ROIImageImage: DevULong —
LineProfileHelperImgImage: DevFloat —
GaussianFitParameterCovarianceImage: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
None.
StopInput: DevVoid
Output: DevVoid
None.
ProcessInput: DevVoid
Output: DevVoid
None.
SaveCurrentSettingsInput: DevVoid
Output: DevVoid
None.
GetVersionNumberInput: DevVoid
Output: DevString
None.

Pipes:

Properties:

Name Description
AutoROIMagFactorXDevDouble initial value of AutoROIMagFactorX attribute. if not defined, it is set to 1
AutoROIMagFactorYDevDouble initial value of AutoROIMagFactorY attribute. if not defined, it is set to 1
AutoROIMethodDevString the method used for computing the AutoROI. can be `PROFILES` or `THRESHOLD`. PROFILES method means the AutoROI is computed from the profiles fitted to gaussian functions. THRESHOLD means that the image is first thresholded using the `AutoROIThreshold` attribute then the largest blob is selected.
AutoStartDevBoolean if set to `true` and mode is `CONTINUOUS`, the computation starts automatically when the device is launched
BitsPerPixelDevLong the initial value of the BitsPerPixel attribute
ComputationPeriodDevLong the initial value of the ComputationPeriod attribute
Enable2DGaussianFitDevBoolean the initial value of the Enable2DGaussianFit attribute
EnableAutoROIDevBoolean the initial value of the EnableAutoROI attribute
EnableHistogramDevBoolean the initial value of the EnableHistogram attribute
EnableImageStatsDevBoolean the initial value of the EnableImageStats attribute
EnableProfilesDevBoolean the initial value of the EnableProfiles attribute
EnableUserROIDevBoolean the initial value of the EnableUserROI attribute
GammaCorrectionDevDouble the initial value of the GammaCorrection attribute
HistogramNbBinsDevLong the initial value of the HistogramNbBins attribute
HistogramRangeMaxDevLong the upper bound of the histogram bins. must be
HistogramRangeMinDevLong the lower bound of the histogram bins. must be> = 0
HorizontalFlipDevBoolean the initial value of the HorizontalFlip attribute
ImageAttributeNameDevString the name of the image attribute to take in ImageDevice
ImageCounterAttrNameDevString the name of the imageCounter attribute to take in ImageDevice
ImageDeviceDevString the device from which the image is taken
ModeDevString ONESHOT or CONTINUOUS
OpticalMagnificationDevDouble the initial value of the OpticalMagnification attribute
PixelSizeXDevDouble the initial value of the PixelSizeX attribute
PixelSizeYDevDouble the initial value of the PixelSizeY attribute
ProfileFitFixedBgDevBoolean the initial value of the ProfileFitFixedBg attribute
RotationDevLong the initial value of the Rotation attribute
UserROIOriginXDevLong The memorized value of userROIOriginX attribute when SaveCurrentSettings command is called.
UserROIOriginYDevLong The memorized value of userROIOriginY attribute when SaveCurrentSettings command is called.
UserROIWidthDevLong The memorized value of userROIWidth attribute when SaveCurrentSettings command is called.
UserROIHeightDevLong The memorized value of userROIHeight attribute when SaveCurrentSettings command is called.
ChamberOffsetXDevDouble the initial value of the ChamberOffsetX attribute
ChamberOffsetYDevDouble the initial value of the ChamberOffsetY attribute
CentroidSaturationRegionSideDevLong the initial value of the CentroidSaturationRegionSide attribute
CentroidSaturationRegionThresholdDevLong the initial value of the CentroidSaturationRegionThreshold attribute


Please log in to comment.

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:41 a.m.