This file contains any messages produced by compilers while running configure, to aid debugging if configure makes a mistake. It was created by zeromq configure 4.1.4, which was generated by GNU Autoconf 2.69. Invocation command line was $ ./configure --prefix=/opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4 CFLAGS=-gstabs+ CXXFLAGS=-gstabs+ ## --------- ## ## Platform. ## ## --------- ## hostname = 01HW252640 uname -m = x86_64 uname -r = 4.4.0-24-generic uname -s = Linux uname -v = #43-Ubuntu SMP Wed Jun 8 19:27:37 UTC 2016 /usr/bin/uname -p = unknown /bin/uname -X = unknown /bin/arch = unknown /usr/bin/arch -k = unknown /usr/convex/getsysinfo = unknown /usr/bin/hostinfo = unknown /bin/machine = unknown /usr/bin/oslevel = unknown /bin/universe = unknown PATH: /usr/local/sbin PATH: /usr/local/bin PATH: /usr/sbin PATH: /usr/bin PATH: /sbin PATH: /bin PATH: /usr/games PATH: /usr/local/games PATH: /snap/bin ## ----------- ## ## Core tests. ## ## ----------- ## configure:2832: checking for a BSD-compatible install configure:2900: result: /usr/bin/install -c configure:2911: checking whether build environment is sane configure:2966: result: yes configure:3117: checking for a thread-safe mkdir -p configure:3156: result: /bin/mkdir -p configure:3163: checking for gawk configure:3193: result: no configure:3163: checking for mawk configure:3179: found /usr/bin/mawk configure:3190: result: mawk configure:3201: checking whether make sets $(MAKE) configure:3223: result: yes configure:3252: checking whether make supports nested variables configure:3269: result: yes configure:3358: checking whether UID '1001' is supported by ustar format configure:3361: result: yes configure:3368: checking whether GID '100' is supported by ustar format configure:3371: result: yes configure:3379: checking how to create a ustar tar archive configure:3390: tar --version tar (GNU tar) 1.28 Copyright (C) 2014 Free Software Foundation, Inc. License GPLv3+: GNU GPL version 3 or later . This is free software: you are free to change and redistribute it. There is NO WARRANTY, to the extent permitted by law. Written by John Gilmore and Jay Fenlason. configure:3393: $? = 0 configure:3433: tardir=conftest.dir && eval tar --format=ustar -chf - "$tardir" >conftest.tar configure:3436: $? = 0 configure:3440: tar -xf - &5 gcc (Ubuntu 5.3.1-14ubuntu2.1) 5.3.1 20160413 Copyright (C) 2015 Free Software Foundation, Inc. This is free software; see the source for copying conditions. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. configure:3903: $? = 0 configure:3892: gcc -v >&5 Using built-in specs. COLLECT_GCC=gcc COLLECT_LTO_WRAPPER=/usr/lib/gcc/x86_64-linux-gnu/5/lto-wrapper Target: x86_64-linux-gnu Configured with: ../src/configure -v --with-pkgversion='Ubuntu 5.3.1-14ubuntu2.1' --with-bugurl=file:///usr/share/doc/gcc-5/README.Bugs --enable-languages=c,ada,c++,java,go,d,fortran,objc,obj-c++ --prefix=/usr --program-suffix=-5 --enable-shared --enable-linker-build-id --libexecdir=/usr/lib --without-included-gettext --enable-threads=posix --libdir=/usr/lib --enable-nls --with-sysroot=/ --enable-clocale=gnu --enable-libstdcxx-debug --enable-libstdcxx-time=yes --with-default-libstdcxx-abi=new --enable-gnu-unique-object --disable-vtable-verify --enable-libmpx --enable-plugin --with-system-zlib --disable-browser-plugin --enable-java-awt=gtk --enable-gtk-cairo --with-java-home=/usr/lib/jvm/java-1.5.0-gcj-5-amd64/jre --enable-java-home --with-jvm-root-dir=/usr/lib/jvm/java-1.5.0-gcj-5-amd64 --with-jvm-jar-dir=/usr/lib/jvm-exports/java-1.5.0-gcj-5-amd64 --with-arch-directory=amd64 --with-ecj-jar=/usr/share/java/eclipse-ecj.jar --enable-objc-gc --enable-multiarch --disable-werror --with-arch-32=i686 --with-abi=m64 --with-multilib-list=m32,m64,mx32 --enable-multilib --with-tune=generic --enable-checking=release --build=x86_64-linux-gnu --host=x86_64-linux-gnu --target=x86_64-linux-gnu Thread model: posix gcc version 5.3.1 20160413 (Ubuntu 5.3.1-14ubuntu2.1) configure:3903: $? = 0 configure:3892: gcc -V >&5 gcc: error: unrecognized command line option '-V' gcc: fatal error: no input files compilation terminated. configure:3903: $? = 1 configure:3892: gcc -qversion >&5 gcc: error: unrecognized command line option '-qversion' gcc: fatal error: no input files compilation terminated. configure:3903: $? = 1 configure:3923: checking whether the C compiler works configure:3945: gcc -gstabs+ conftest.c >&5 configure:3949: $? = 0 configure:3997: result: yes configure:4000: checking for C compiler default output file name configure:4002: result: a.out configure:4008: checking for suffix of executables configure:4015: gcc -o conftest -gstabs+ conftest.c >&5 configure:4019: $? = 0 configure:4041: result: configure:4063: checking whether we are cross compiling configure:4071: gcc -o conftest -gstabs+ conftest.c >&5 configure:4075: $? = 0 configure:4082: ./conftest configure:4086: $? = 0 configure:4101: result: no configure:4106: checking for suffix of object files configure:4128: gcc -c -gstabs+ conftest.c >&5 configure:4132: $? = 0 configure:4153: result: o configure:4157: checking whether we are using the GNU C compiler configure:4176: gcc -c -gstabs+ conftest.c >&5 configure:4176: $? = 0 configure:4185: result: yes configure:4194: checking whether gcc accepts -g configure:4214: gcc -c -g conftest.c >&5 configure:4214: $? = 0 configure:4255: result: yes configure:4272: checking for gcc option to accept ISO C89 configure:4335: gcc -c -gstabs+ conftest.c >&5 configure:4335: $? = 0 configure:4348: result: none needed configure:4373: checking whether gcc understands -c and -o together configure:4395: gcc -c conftest.c -o conftest2.o configure:4398: $? = 0 configure:4395: gcc -c conftest.c -o conftest2.o configure:4398: $? = 0 configure:4410: result: yes configure:4438: checking for style of include used by make configure:4466: result: GNU configure:4492: checking dependency style of gcc configure:4603: result: gcc3 configure:4618: checking for gcc option to accept ISO C99 configure:4767: gcc -c -gstabs+ conftest.c >&5 configure:4767: $? = 0 configure:4780: result: none needed configure:4853: checking for g++ configure:4869: found /usr/bin/g++ configure:4880: result: g++ configure:4907: checking for C++ compiler version configure:4916: g++ --version >&5 g++ (Ubuntu 5.3.1-14ubuntu2.1) 5.3.1 20160413 Copyright (C) 2015 Free Software Foundation, Inc. This is free software; see the source for copying conditions. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. configure:4927: $? = 0 configure:4916: g++ -v >&5 Using built-in specs. COLLECT_GCC=g++ COLLECT_LTO_WRAPPER=/usr/lib/gcc/x86_64-linux-gnu/5/lto-wrapper Target: x86_64-linux-gnu Configured with: ../src/configure -v --with-pkgversion='Ubuntu 5.3.1-14ubuntu2.1' --with-bugurl=file:///usr/share/doc/gcc-5/README.Bugs --enable-languages=c,ada,c++,java,go,d,fortran,objc,obj-c++ --prefix=/usr --program-suffix=-5 --enable-shared --enable-linker-build-id --libexecdir=/usr/lib --without-included-gettext --enable-threads=posix --libdir=/usr/lib --enable-nls --with-sysroot=/ --enable-clocale=gnu --enable-libstdcxx-debug --enable-libstdcxx-time=yes --with-default-libstdcxx-abi=new --enable-gnu-unique-object --disable-vtable-verify --enable-libmpx --enable-plugin --with-system-zlib --disable-browser-plugin --enable-java-awt=gtk --enable-gtk-cairo --with-java-home=/usr/lib/jvm/java-1.5.0-gcj-5-amd64/jre --enable-java-home --with-jvm-root-dir=/usr/lib/jvm/java-1.5.0-gcj-5-amd64 --with-jvm-jar-dir=/usr/lib/jvm-exports/java-1.5.0-gcj-5-amd64 --with-arch-directory=amd64 --with-ecj-jar=/usr/share/java/eclipse-ecj.jar --enable-objc-gc --enable-multiarch --disable-werror --with-arch-32=i686 --with-abi=m64 --with-multilib-list=m32,m64,mx32 --enable-multilib --with-tune=generic --enable-checking=release --build=x86_64-linux-gnu --host=x86_64-linux-gnu --target=x86_64-linux-gnu Thread model: posix gcc version 5.3.1 20160413 (Ubuntu 5.3.1-14ubuntu2.1) configure:4927: $? = 0 configure:4916: g++ -V >&5 g++: error: unrecognized command line option '-V' g++: fatal error: no input files compilation terminated. configure:4927: $? = 1 configure:4916: g++ -qversion >&5 g++: error: unrecognized command line option '-qversion' g++: fatal error: no input files compilation terminated. configure:4927: $? = 1 configure:4931: checking whether we are using the GNU C++ compiler configure:4950: g++ -c -gstabs+ conftest.cpp >&5 configure:4950: $? = 0 configure:4959: result: yes configure:4968: checking whether g++ accepts -g configure:4988: g++ -c -g conftest.cpp >&5 configure:4988: $? = 0 configure:5029: result: yes configure:5054: checking dependency style of g++ configure:5165: result: gcc3 configure:5181: checking for a sed that does not truncate output configure:5245: result: /bin/sed configure:5254: checking for gawk configure:5281: result: mawk configure:5346: checking for pkg-config configure:5364: found /usr/bin/pkg-config configure:5376: result: /usr/bin/pkg-config configure:5401: checking pkg-config is at least version 0.9.0 configure:5404: result: yes configure:5417: checking for xmlto configure:5450: result: no configure:5458: checking for asciidoc configure:5491: result: no configure:5500: checking build system type configure:5514: result: x86_64-unknown-linux-gnu configure:5534: checking host system type configure:5547: result: x86_64-unknown-linux-gnu configure:5988: checking how to print strings configure:6015: result: printf configure:6036: checking for a sed that does not truncate output configure:6100: result: /bin/sed configure:6118: checking for grep that handles long lines and -e configure:6176: result: /bin/grep configure:6181: checking for egrep configure:6243: result: /bin/grep -E configure:6248: checking for fgrep configure:6310: result: /bin/grep -F configure:6345: checking for ld used by gcc configure:6412: result: /usr/bin/ld configure:6419: checking if the linker (/usr/bin/ld) is GNU ld configure:6434: result: yes configure:6446: checking for BSD- or MS-compatible name lister (nm) configure:6495: result: /usr/bin/nm -B configure:6625: checking the name lister (/usr/bin/nm -B) interface configure:6632: gcc -c -gstabs+ conftest.c >&5 configure:6635: /usr/bin/nm -B "conftest.o" configure:6638: output 0000000000000000 B some_variable configure:6645: result: BSD nm configure:6648: checking whether ln -s works configure:6652: result: yes configure:6660: checking the maximum length of command line arguments configure:6791: result: 1572864 configure:6808: checking whether the shell understands some XSI constructs configure:6818: result: yes configure:6822: checking whether the shell understands "+=" configure:6828: result: yes configure:6863: checking how to convert x86_64-unknown-linux-gnu file names to x86_64-unknown-linux-gnu format configure:6903: result: func_convert_file_noop configure:6910: checking how to convert x86_64-unknown-linux-gnu file names to toolchain format configure:6930: result: func_convert_file_noop configure:6937: checking for /usr/bin/ld option to reload object files configure:6944: result: -r configure:7018: checking for objdump configure:7045: result: objdump configure:7074: checking how to recognize dependent libraries configure:7272: result: pass_all configure:7357: checking for dlltool configure:7384: result: dlltool configure:7414: checking how to associate runtime and link libraries configure:7441: result: printf %s\n configure:7502: checking for ar configure:7518: found /usr/bin/ar configure:7529: result: ar configure:7566: checking for archiver @FILE support configure:7583: gcc -c -gstabs+ conftest.c >&5 configure:7583: $? = 0 configure:7586: ar cru libconftest.a @conftest.lst >&5 ar: `u' modifier ignored since `D' is the default (see `U') configure:7589: $? = 0 configure:7594: ar cru libconftest.a @conftest.lst >&5 ar: `u' modifier ignored since `D' is the default (see `U') ar: conftest.o: No such file or directory configure:7597: $? = 1 configure:7609: result: @ configure:7667: checking for strip configure:7683: found /usr/bin/strip configure:7694: result: strip configure:7766: checking for ranlib configure:7782: found /usr/bin/ranlib configure:7793: result: ranlib configure:7895: checking command to parse /usr/bin/nm -B output from gcc object configure:8015: gcc -c -gstabs+ conftest.c >&5 configure:8018: $? = 0 configure:8022: /usr/bin/nm -B conftest.o \| sed -n -e 's/^.*[ ]\([ABCDGIRSTW][ABCDGIRSTW]*\)[ ][ ]*\([_A-Za-z][_A-Za-z0-9]*\)$/\1 \2 \2/p' | sed '/ __gnu_lto/d' \> conftest.nm configure:8025: $? = 0 configure:8091: gcc -o conftest -gstabs+ conftest.c conftstm.o >&5 configure:8094: $? = 0 configure:8132: result: ok configure:8169: checking for sysroot configure:8199: result: no configure:8276: gcc -c -gstabs+ conftest.c >&5 configure:8279: $? = 0 configure:8468: checking for mt configure:8484: found /bin/mt configure:8495: result: mt configure:8518: checking if mt is a manifest tool configure:8524: mt '-?' configure:8532: result: no configure:9174: checking how to run the C preprocessor configure:9205: gcc -E conftest.c configure:9205: $? = 0 configure:9219: gcc -E conftest.c conftest.c:11:28: fatal error: ac_nonexistent.h: No such file or directory compilation terminated. configure:9219: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | /* end confdefs.h. */ | #include configure:9244: result: gcc -E configure:9264: gcc -E conftest.c configure:9264: $? = 0 configure:9278: gcc -E conftest.c conftest.c:11:28: fatal error: ac_nonexistent.h: No such file or directory compilation terminated. configure:9278: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | /* end confdefs.h. */ | #include configure:9307: checking for ANSI C header files configure:9327: gcc -c -gstabs+ conftest.c >&5 configure:9327: $? = 0 configure:9400: gcc -o conftest -gstabs+ conftest.c >&5 configure:9400: $? = 0 configure:9400: ./conftest configure:9400: $? = 0 configure:9411: result: yes configure:9424: checking for sys/types.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for sys/stat.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for stdlib.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for string.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for memory.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for strings.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for inttypes.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for stdint.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9424: checking for unistd.h configure:9424: gcc -c -gstabs+ conftest.c >&5 configure:9424: $? = 0 configure:9424: result: yes configure:9438: checking for dlfcn.h configure:9438: gcc -c -gstabs+ conftest.c >&5 configure:9438: $? = 0 configure:9438: result: yes configure:9623: checking for objdir configure:9638: result: .libs configure:9909: checking if gcc supports -fno-rtti -fno-exceptions configure:9927: gcc -c -gstabs+ -fno-rtti -fno-exceptions conftest.c >&5 cc1: warning: command line option '-fno-rtti' is valid for C++/ObjC++ but not for C configure:9931: $? = 0 configure:9944: result: no configure:10271: checking for gcc option to produce PIC configure:10278: result: -fPIC -DPIC configure:10286: checking if gcc PIC flag -fPIC -DPIC works configure:10304: gcc -c -gstabs+ -fPIC -DPIC -DPIC conftest.c >&5 configure:10308: $? = 0 configure:10321: result: yes configure:10350: checking if gcc static flag -static works configure:10378: result: yes configure:10393: checking if gcc supports -c -o file.o configure:10414: gcc -c -gstabs+ -o out/conftest2.o conftest.c >&5 configure:10418: $? = 0 configure:10440: result: yes configure:10448: checking if gcc supports -c -o file.o configure:10495: result: yes configure:10528: checking whether the gcc linker (/usr/bin/ld -m elf_x86_64) supports shared libraries configure:11685: result: yes configure:11722: checking whether -lc should be explicitly linked in configure:11730: gcc -c -gstabs+ conftest.c >&5 configure:11733: $? = 0 configure:11748: gcc -shared -fPIC -DPIC conftest.o -v -Wl,-soname -Wl,conftest -o conftest 2\>\&1 \| /bin/grep -lc \>/dev/null 2\>\&1 configure:11751: $? = 0 configure:11765: result: no configure:11925: checking dynamic linker characteristics configure:12425: gcc -o conftest -gstabs+ -Wl,-rpath -Wl,/foo conftest.c >&5 configure:12425: $? = 0 configure:12659: result: GNU/Linux ld.so configure:12766: checking how to hardcode library paths into programs configure:12791: result: immediate configure:13331: checking whether stripping libraries is possible configure:13336: result: yes configure:13371: checking if libtool supports shared libraries configure:13373: result: yes configure:13376: checking whether to build shared libraries configure:13397: result: yes configure:13400: checking whether to build static libraries configure:13404: result: yes configure:13427: checking how to run the C++ preprocessor configure:13454: g++ -E conftest.cpp configure:13454: $? = 0 configure:13468: g++ -E conftest.cpp conftest.cpp:23:28: fatal error: ac_nonexistent.h: No such file or directory compilation terminated. configure:13468: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | #include configure:13493: result: g++ -E configure:13513: g++ -E conftest.cpp configure:13513: $? = 0 configure:13527: g++ -E conftest.cpp conftest.cpp:23:28: fatal error: ac_nonexistent.h: No such file or directory compilation terminated. configure:13527: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | #include configure:13696: checking for ld used by g++ configure:13763: result: /usr/bin/ld -m elf_x86_64 configure:13770: checking if the linker (/usr/bin/ld -m elf_x86_64) is GNU ld configure:13785: result: yes configure:13840: checking whether the g++ linker (/usr/bin/ld -m elf_x86_64) supports shared libraries configure:14842: result: yes configure:14878: g++ -c -gstabs+ conftest.cpp >&5 configure:14881: $? = 0 configure:15401: checking for g++ option to produce PIC configure:15408: result: -fPIC -DPIC configure:15416: checking if g++ PIC flag -fPIC -DPIC works configure:15434: g++ -c -gstabs+ -fPIC -DPIC -DPIC conftest.cpp >&5 configure:15438: $? = 0 configure:15451: result: yes configure:15474: checking if g++ static flag -static works configure:15502: result: yes configure:15514: checking if g++ supports -c -o file.o configure:15535: g++ -c -gstabs+ -o out/conftest2.o conftest.cpp >&5 configure:15539: $? = 0 configure:15561: result: yes configure:15566: checking if g++ supports -c -o file.o configure:15613: result: yes configure:15643: checking whether the g++ linker (/usr/bin/ld -m elf_x86_64) supports shared libraries configure:15682: result: yes configure:15823: checking dynamic linker characteristics configure:16491: result: GNU/Linux ld.so configure:16544: checking how to hardcode library paths into programs configure:16569: result: immediate configure:16642: checking whether the C compiler works configure:16658: gcc -o conftest -gstabs+ conftest.c >&5 configure:16658: $? = 0 configure:16667: result: yes configure:16675: checking whether we are using Intel C compiler configure:16694: gcc -c -gstabs+ conftest.c >&5 conftest.c: In function 'main': conftest.c:28:8: error: 'error' undeclared (first use in this function) error if not ICC ^ conftest.c:28:8: note: each undeclared identifier is reported only once for each function it appears in conftest.c:28:14: error: expected ';' before 'if' error if not ICC ^ configure:16694: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | | int | main () | { | #ifndef __INTEL_COMPILER | error if not ICC | #endif | | ; | return 0; | } configure:16702: result: no configure:16704: checking whether we are using Sun Studio C compiler configure:16723: gcc -c -gstabs+ conftest.c >&5 conftest.c: In function 'main': conftest.c:28:8: error: 'error' undeclared (first use in this function) error if not sun studio ^ conftest.c:28:8: note: each undeclared identifier is reported only once for each function it appears in conftest.c:28:14: error: expected ';' before 'if' error if not sun studio ^ configure:16723: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | | int | main () | { | #if !defined(__SUNPRO_CC) && !defined(__SUNPRO_C) | error if not sun studio | #endif | | ; | return 0; | } configure:16731: result: no configure:16733: checking whether we are using clang C compiler configure:16752: gcc -c -gstabs+ conftest.c >&5 conftest.c: In function 'main': conftest.c:28:8: error: 'error' undeclared (first use in this function) error if not clang ^ conftest.c:28:8: note: each undeclared identifier is reported only once for each function it appears in conftest.c:28:14: error: expected ';' before 'if' error if not clang ^ configure:16752: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | | int | main () | { | #ifndef __clang__ | error if not clang | #endif | | ; | return 0; | } configure:16760: result: no configure:16762: checking whether we are using gcc >= 4 C compiler configure:16781: gcc -c -gstabs+ conftest.c >&5 configure:16781: $? = 0 configure:16789: result: yes configure:16806: checking whether the C++ compiler works configure:16822: g++ -o conftest -gstabs+ conftest.cpp >&5 configure:16822: $? = 0 configure:16831: result: yes configure:16839: checking whether we are using Intel C++ compiler configure:16858: g++ -c -gstabs+ conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:28:8: error: 'error' was not declared in this scope error if not ICC ^ configure:16858: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | | int | main () | { | #ifndef __INTEL_COMPILER | error if not ICC | #endif | | ; | return 0; | } configure:16866: result: no configure:16868: checking whether we are using Sun Studio C++ compiler configure:16887: g++ -c -gstabs+ conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:28:8: error: 'error' was not declared in this scope error if not sun studio ^ configure:16887: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | | int | main () | { | #if !defined(__SUNPRO_CC) && !defined(__SUNPRO_C) | error if not sun studio | #endif | | ; | return 0; | } configure:16895: result: no configure:16897: checking whether we are using clang C++ compiler configure:16916: g++ -c -gstabs+ conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:28:8: error: 'error' was not declared in this scope error if not clang ^ configure:16916: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | | int | main () | { | #ifndef __clang__ | error if not clang | #endif | | ; | return 0; | } configure:16924: result: no configure:16926: checking whether we are using gcc >= 4 C++ compiler configure:16945: g++ -c -gstabs+ conftest.cpp >&5 configure:16945: $? = 0 configure:16953: result: yes configure:16987: checking whether to enable debugging information configure:17025: result: no configure:17042: checking whether to enable code coverage configure:17073: result: no configure:17080: checking if TIPC is available and supports nonblocking connect configure:17121: gcc -o conftest -gstabs+ conftest.c >&5 configure:17121: $? = 0 configure:17121: ./conftest configure:17121: $? = 255 configure: program exited with status 255 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | /* end confdefs.h. */ | | #include | #include | #include | #include | #include | #include | | int | main () | { | | struct sockaddr_tipc topsrv; | int sd = socket(AF_TIPC, SOCK_SEQPACKET, 0); | if (sd == -EAFNOSUPPORT) { | return 1; | } | memset(&topsrv, 0, sizeof(topsrv)); | topsrv.family = AF_TIPC; | topsrv.addrtype = TIPC_ADDR_NAME; | topsrv.addr.name.name.type = TIPC_TOP_SRV; | topsrv.addr.name.name.instance = TIPC_TOP_SRV; | fcntl(sd, F_SETFL, O_NONBLOCK); | if (connect(sd, (struct sockaddr *)&topsrv, sizeof(topsrv)) != 0) { | if (errno != EINPROGRESS) | return -1; | } | | ; | return 0; | } | configure:17131: result: no configure:17940: checking for pthread_create in -lpthread configure:17965: gcc -o conftest -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE conftest.c -lpthread >&5 configure:17965: $? = 0 configure:17974: result: yes configure:17985: checking for clock_gettime in -lrt configure:18010: gcc -o conftest -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE conftest.c -lrt -lpthread >&5 configure:18010: $? = 0 configure:18019: result: yes configure:18052: checking whether C++ compiler supports -fvisibility=hidden configure:18084: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -fvisibility=hidden conftest.cpp >&5 configure:18084: $? = 0 configure:18115: result: yes configure:18201: checking whether C++ compiler supports dso visibility configure:18205: result: yes configure:18349: checking for asciidoc configure:18377: result: no configure:18387: checking for xmlto configure:18415: result: no configure:18441: checking whether to build documentation configure:18443: result: no configure:18446: checking whether to install manpages configure:18448: result: yes configure:18491: checking for suitable polling system configure:18517: gcc -o conftest -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE conftest.c -lrt -lpthread >&5 conftest.c:28:23: fatal error: sys/event.h: No such file or directory compilation terminated. configure:18517: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | #define ZMQ_HAVE_LINUX 1 | #define HAVE_LIBPTHREAD 1 | #define HAVE_LIBRT 1 | /* end confdefs.h. */ | | #include | #include | #include | | int | main () | { | | struct kevent t_kev; | kqueue(); | | | ; | return 0; | } configure:18577: gcc -o conftest -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE conftest.c -lrt -lpthread >&5 configure:18577: $? = 0 configure:18577: ./conftest configure:18577: $? = 0 configure:18702: result: using epoll configure:18711: checking for ANSI C header files configure:18815: result: yes configure:18838: checking errno.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking errno.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for errno.h configure:18838: result: yes configure:18838: checking time.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking time.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for time.h configure:18838: result: yes configure:18838: checking for unistd.h configure:18838: result: yes configure:18838: checking limits.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking limits.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for limits.h configure:18838: result: yes configure:18838: checking stddef.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking stddef.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for stddef.h configure:18838: result: yes configure:18838: checking for stdlib.h configure:18838: result: yes configure:18838: checking for string.h configure:18838: result: yes configure:18838: checking arpa/inet.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking arpa/inet.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for arpa/inet.h configure:18838: result: yes configure:18838: checking netinet/tcp.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking netinet/tcp.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for netinet/tcp.h configure:18838: result: yes configure:18838: checking netinet/in.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking netinet/in.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for netinet/in.h configure:18838: result: yes configure:18838: checking sys/socket.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking sys/socket.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for sys/socket.h configure:18838: result: yes configure:18838: checking sys/time.h usability configure:18838: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking sys/time.h presence configure:18838: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18838: $? = 0 configure:18838: result: yes configure:18838: checking for sys/time.h configure:18838: result: yes configure:18852: checking ifaddrs.h usability configure:18852: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18852: $? = 0 configure:18852: result: yes configure:18852: checking ifaddrs.h presence configure:18852: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18852: $? = 0 configure:18852: result: yes configure:18852: checking for ifaddrs.h configure:18852: result: yes configure:18868: checking sys/uio.h usability configure:18868: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18868: $? = 0 configure:18868: result: yes configure:18868: checking sys/uio.h presence configure:18868: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18868: $? = 0 configure:18868: result: yes configure:18868: checking for sys/uio.h configure:18868: result: yes configure:18894: checking sys/eventfd.h usability configure:18894: gcc -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c >&5 configure:18894: $? = 0 configure:18894: result: yes configure:18894: checking sys/eventfd.h presence configure:18894: gcc -E -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.c configure:18894: $? = 0 configure:18894: result: yes configure:18894: checking for sys/eventfd.h configure:18894: result: yes configure:18916: checking whether SO_PEERCRED is declared configure:18916: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:18916: $? = 0 configure:18916: result: yes configure:18934: checking whether LOCAL_PEERCRED is declared configure:18934: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:54:10: error: 'LOCAL_PEERCRED' was not declared in this scope (void) LOCAL_PEERCRED; ^ configure:18934: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | #define ZMQ_HAVE_LINUX 1 | #define HAVE_LIBPTHREAD 1 | #define HAVE_LIBRT 1 | #define STDC_HEADERS 1 | #define HAVE_ERRNO_H 1 | #define HAVE_TIME_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_LIMITS_H 1 | #define HAVE_STDDEF_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_ARPA_INET_H 1 | #define HAVE_NETINET_TCP_H 1 | #define HAVE_NETINET_IN_H 1 | #define HAVE_SYS_SOCKET_H 1 | #define HAVE_SYS_TIME_H 1 | #define HAVE_IFADDRS_H 1 | #define ZMQ_HAVE_IFADDRS 1 | #define HAVE_SYS_UIO_H 1 | #define ZMQ_HAVE_UIO 1 | #define HAVE_SYS_EVENTFD_H 1 | #define ZMQ_HAVE_EVENTFD 1 | #define HAVE_DECL_SO_PEERCRED 1 | #define ZMQ_HAVE_SO_PEERCRED 1 | /* end confdefs.h. */ | #include | | int | main () | { | #ifndef LOCAL_PEERCRED | #ifdef __cplusplus | (void) LOCAL_PEERCRED; | #else | (void) LOCAL_PEERCRED; | #endif | #endif | | ; | return 0; | } configure:18934: result: no configure:18961: checking for stdbool.h that conforms to C99 configure:19028: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19028: $? = 0 configure:19035: result: yes configure:19037: checking for _Bool configure:19037: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:84:13: error: '_Bool' was not declared in this scope if (sizeof (_Bool)) ^ configure:19037: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | #define ZMQ_HAVE_LINUX 1 | #define HAVE_LIBPTHREAD 1 | #define HAVE_LIBRT 1 | #define STDC_HEADERS 1 | #define HAVE_ERRNO_H 1 | #define HAVE_TIME_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_LIMITS_H 1 | #define HAVE_STDDEF_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_ARPA_INET_H 1 | #define HAVE_NETINET_TCP_H 1 | #define HAVE_NETINET_IN_H 1 | #define HAVE_SYS_SOCKET_H 1 | #define HAVE_SYS_TIME_H 1 | #define HAVE_IFADDRS_H 1 | #define ZMQ_HAVE_IFADDRS 1 | #define HAVE_SYS_UIO_H 1 | #define ZMQ_HAVE_UIO 1 | #define HAVE_SYS_EVENTFD_H 1 | #define ZMQ_HAVE_EVENTFD 1 | #define HAVE_DECL_SO_PEERCRED 1 | #define ZMQ_HAVE_SO_PEERCRED 1 | #define HAVE_DECL_LOCAL_PEERCRED 0 | /* end confdefs.h. */ | #include | #ifdef HAVE_SYS_TYPES_H | # include | #endif | #ifdef HAVE_SYS_STAT_H | # include | #endif | #ifdef STDC_HEADERS | # include | # include | #else | # ifdef HAVE_STDLIB_H | # include | # endif | #endif | #ifdef HAVE_STRING_H | # if !defined STDC_HEADERS && defined HAVE_MEMORY_H | # include | # endif | # include | #endif | #ifdef HAVE_STRINGS_H | # include | #endif | #ifdef HAVE_INTTYPES_H | # include | #endif | #ifdef HAVE_STDINT_H | # include | #endif | #ifdef HAVE_UNISTD_H | # include | #endif | int | main () | { | if (sizeof (_Bool)) | return 0; | ; | return 0; | } configure:19037: result: no configure:19054: checking for an ANSI C-conforming const configure:19120: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19120: $? = 0 configure:19127: result: yes configure:19135: checking for inline configure:19151: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19151: $? = 0 configure:19159: result: inline configure:19227: checking for size_t configure:19227: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19227: $? = 0 configure:19227: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:85:20: error: expected primary-expression before ')' token if (sizeof ((size_t))) ^ configure:19227: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | #define ZMQ_HAVE_LINUX 1 | #define HAVE_LIBPTHREAD 1 | #define HAVE_LIBRT 1 | #define STDC_HEADERS 1 | #define HAVE_ERRNO_H 1 | #define HAVE_TIME_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_LIMITS_H 1 | #define HAVE_STDDEF_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_ARPA_INET_H 1 | #define HAVE_NETINET_TCP_H 1 | #define HAVE_NETINET_IN_H 1 | #define HAVE_SYS_SOCKET_H 1 | #define HAVE_SYS_TIME_H 1 | #define HAVE_IFADDRS_H 1 | #define ZMQ_HAVE_IFADDRS 1 | #define HAVE_SYS_UIO_H 1 | #define ZMQ_HAVE_UIO 1 | #define HAVE_SYS_EVENTFD_H 1 | #define ZMQ_HAVE_EVENTFD 1 | #define HAVE_DECL_SO_PEERCRED 1 | #define ZMQ_HAVE_SO_PEERCRED 1 | #define HAVE_DECL_LOCAL_PEERCRED 0 | #define HAVE_STDBOOL_H 1 | /* end confdefs.h. */ | #include | #ifdef HAVE_SYS_TYPES_H | # include | #endif | #ifdef HAVE_SYS_STAT_H | # include | #endif | #ifdef STDC_HEADERS | # include | # include | #else | # ifdef HAVE_STDLIB_H | # include | # endif | #endif | #ifdef HAVE_STRING_H | # if !defined STDC_HEADERS && defined HAVE_MEMORY_H | # include | # endif | # include | #endif | #ifdef HAVE_STRINGS_H | # include | #endif | #ifdef HAVE_INTTYPES_H | # include | #endif | #ifdef HAVE_STDINT_H | # include | #endif | #ifdef HAVE_UNISTD_H | # include | #endif | int | main () | { | if (sizeof ((size_t))) | return 0; | ; | return 0; | } configure:19227: result: yes configure:19238: checking for ssize_t configure:19238: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19238: $? = 0 configure:19238: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:85:21: error: expected primary-expression before ')' token if (sizeof ((ssize_t))) ^ configure:19238: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | #define ZMQ_HAVE_LINUX 1 | #define HAVE_LIBPTHREAD 1 | #define HAVE_LIBRT 1 | #define STDC_HEADERS 1 | #define HAVE_ERRNO_H 1 | #define HAVE_TIME_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_LIMITS_H 1 | #define HAVE_STDDEF_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_ARPA_INET_H 1 | #define HAVE_NETINET_TCP_H 1 | #define HAVE_NETINET_IN_H 1 | #define HAVE_SYS_SOCKET_H 1 | #define HAVE_SYS_TIME_H 1 | #define HAVE_IFADDRS_H 1 | #define ZMQ_HAVE_IFADDRS 1 | #define HAVE_SYS_UIO_H 1 | #define ZMQ_HAVE_UIO 1 | #define HAVE_SYS_EVENTFD_H 1 | #define ZMQ_HAVE_EVENTFD 1 | #define HAVE_DECL_SO_PEERCRED 1 | #define ZMQ_HAVE_SO_PEERCRED 1 | #define HAVE_DECL_LOCAL_PEERCRED 0 | #define HAVE_STDBOOL_H 1 | /* end confdefs.h. */ | #include | #ifdef HAVE_SYS_TYPES_H | # include | #endif | #ifdef HAVE_SYS_STAT_H | # include | #endif | #ifdef STDC_HEADERS | # include | # include | #else | # ifdef HAVE_STDLIB_H | # include | # endif | #endif | #ifdef HAVE_STRING_H | # if !defined STDC_HEADERS && defined HAVE_MEMORY_H | # include | # endif | # include | #endif | #ifdef HAVE_STRINGS_H | # include | #endif | #ifdef HAVE_INTTYPES_H | # include | #endif | #ifdef HAVE_STDINT_H | # include | #endif | #ifdef HAVE_UNISTD_H | # include | #endif | int | main () | { | if (sizeof ((ssize_t))) | return 0; | ; | return 0; | } configure:19238: result: yes configure:19251: checking whether time.h and sys/time.h may both be included configure:19271: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19271: $? = 0 configure:19278: result: yes configure:19286: checking for uint32_t configure:19286: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19286: $? = 0 configure:19286: result: yes configure:19300: checking for working volatile configure:19319: g++ -c -gstabs+ -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:19319: $? = 0 configure:19326: result: yes configure:19412: checking for sodium configure:19419: $PKG_CONFIG --exists --print-errors "libsodium" configure:19422: $? = 0 configure:19436: $PKG_CONFIG --exists --print-errors "libsodium" configure:19439: $? = 0 configure:19497: result: yes configure:19815: checking "with_norm_ext = no" configure:19843: checking how to enable additional warnings for C++ compiler configure:19878: result: -Wall configure:19890: checking how to turn warnings to errors in C++ compiler configure:19921: result: -Werror configure:19934: checking how to enable strict standards compliance in C++ compiler configure:19969: result: -pedantic configure:20020: checking return type of signal handlers configure:20038: g++ -c -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 conftest.cpp: In function 'int main()': conftest.cpp:57:25: error: void value not ignored as it ought to be return *(signal (0, 0)) (0) == 1; ^ configure:20038: $? = 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | #define ZMQ_HAVE_LINUX 1 | #define HAVE_LIBPTHREAD 1 | #define HAVE_LIBRT 1 | #define STDC_HEADERS 1 | #define HAVE_ERRNO_H 1 | #define HAVE_TIME_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_LIMITS_H 1 | #define HAVE_STDDEF_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_ARPA_INET_H 1 | #define HAVE_NETINET_TCP_H 1 | #define HAVE_NETINET_IN_H 1 | #define HAVE_SYS_SOCKET_H 1 | #define HAVE_SYS_TIME_H 1 | #define HAVE_IFADDRS_H 1 | #define ZMQ_HAVE_IFADDRS 1 | #define HAVE_SYS_UIO_H 1 | #define ZMQ_HAVE_UIO 1 | #define HAVE_SYS_EVENTFD_H 1 | #define ZMQ_HAVE_EVENTFD 1 | #define HAVE_DECL_SO_PEERCRED 1 | #define ZMQ_HAVE_SO_PEERCRED 1 | #define HAVE_DECL_LOCAL_PEERCRED 0 | #define HAVE_STDBOOL_H 1 | #define TIME_WITH_SYS_TIME 1 | #define HAVE_LIBSODIUM 1 | /* end confdefs.h. */ | #include | #include | | int | main () | { | return *(signal (0, 0)) (0) == 1; | ; | return 0; | } configure:20045: result: void configure:20056: checking for perror configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20056: checking for gettimeofday configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20056: checking for clock_gettime configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20056: checking for memset configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20056: checking for socket configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20056: checking for getifaddrs configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20056: checking for freeifaddrs configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20056: checking for fork configure:20056: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20056: $? = 0 configure:20056: result: yes configure:20068: checking alloca.h usability configure:20068: g++ -c -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp >&5 configure:20068: $? = 0 configure:20068: result: yes configure:20068: checking alloca.h presence configure:20068: g++ -E -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp configure:20068: $? = 0 configure:20068: result: yes configure:20068: checking for alloca.h configure:20068: result: yes configure:20080: checking whether SOCK_CLOEXEC is supported configure:20100: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20100: $? = 0 configure:20100: ./conftest configure:20100: $? = 0 configure:20101: result: yes configure:20119: checking whether SO_KEEPALIVE is supported configure:20142: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20142: $? = 0 configure:20142: ./conftest configure:20142: $? = 0 configure:20143: result: yes configure:20160: checking whether TCP_KEEPCNT is supported configure:20186: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20186: $? = 0 configure:20186: ./conftest configure:20186: $? = 0 configure:20187: result: yes configure:20204: checking whether TCP_KEEPIDLE is supported configure:20230: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20230: $? = 0 configure:20230: ./conftest configure:20230: $? = 0 configure:20231: result: yes configure:20248: checking whether TCP_KEEPINTVL is supported configure:20274: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 configure:20274: $? = 0 configure:20274: ./conftest configure:20274: $? = 0 configure:20275: result: yes configure:20292: checking whether TCP_KEEPALIVE is supported configure:20318: g++ -o conftest -gstabs+ -pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL conftest.cpp -lrt -lpthread >&5 conftest.cpp: In function 'int main(int, char**)': conftest.cpp:78:44: error: 'TCP_KEEPALIVE' was not declared in this scope ((rc = setsockopt (s, IPPROTO_TCP, TCP_KEEPALIVE, (char*) &opt, sizeof (int))) == -1) ^ configure:20318: $? = 1 configure: program exited with status 1 configure: failed program was: | /* confdefs.h */ | #define PACKAGE_NAME "zeromq" | #define PACKAGE_TARNAME "zeromq" | #define PACKAGE_VERSION "4.1.4" | #define PACKAGE_STRING "zeromq 4.1.4" | #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" | #define PACKAGE_URL "" | #define PACKAGE "zeromq" | #define VERSION "4.1.4" | #define STDC_HEADERS 1 | #define HAVE_SYS_TYPES_H 1 | #define HAVE_SYS_STAT_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_MEMORY_H 1 | #define HAVE_STRINGS_H 1 | #define HAVE_INTTYPES_H 1 | #define HAVE_STDINT_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_DLFCN_H 1 | #define LT_OBJDIR ".libs/" | #define ZMQ_HAVE_LINUX 1 | #define HAVE_LIBPTHREAD 1 | #define HAVE_LIBRT 1 | #define STDC_HEADERS 1 | #define HAVE_ERRNO_H 1 | #define HAVE_TIME_H 1 | #define HAVE_UNISTD_H 1 | #define HAVE_LIMITS_H 1 | #define HAVE_STDDEF_H 1 | #define HAVE_STDLIB_H 1 | #define HAVE_STRING_H 1 | #define HAVE_ARPA_INET_H 1 | #define HAVE_NETINET_TCP_H 1 | #define HAVE_NETINET_IN_H 1 | #define HAVE_SYS_SOCKET_H 1 | #define HAVE_SYS_TIME_H 1 | #define HAVE_IFADDRS_H 1 | #define ZMQ_HAVE_IFADDRS 1 | #define HAVE_SYS_UIO_H 1 | #define ZMQ_HAVE_UIO 1 | #define HAVE_SYS_EVENTFD_H 1 | #define ZMQ_HAVE_EVENTFD 1 | #define HAVE_DECL_SO_PEERCRED 1 | #define ZMQ_HAVE_SO_PEERCRED 1 | #define HAVE_DECL_LOCAL_PEERCRED 0 | #define HAVE_STDBOOL_H 1 | #define TIME_WITH_SYS_TIME 1 | #define HAVE_LIBSODIUM 1 | #define RETSIGTYPE void | #define HAVE_PERROR 1 | #define HAVE_GETTIMEOFDAY 1 | #define HAVE_CLOCK_GETTIME 1 | #define HAVE_MEMSET 1 | #define HAVE_SOCKET 1 | #define HAVE_GETIFADDRS 1 | #define HAVE_FREEIFADDRS 1 | #define HAVE_FORK 1 | #define HAVE_ALLOCA_H 1 | #define ZMQ_HAVE_SOCK_CLOEXEC 1 | #define ZMQ_HAVE_SO_KEEPALIVE 1 | #define ZMQ_HAVE_TCP_KEEPCNT 1 | #define ZMQ_HAVE_TCP_KEEPIDLE 1 | #define ZMQ_HAVE_TCP_KEEPINTVL 1 | /* end confdefs.h. */ | /* TCP_KEEPALIVE test */ | #include | #include | #include | #include | | int main (int argc, char *argv []) | { | int s, rc, opt = 1; | return ( | ((s = socket (PF_INET, SOCK_STREAM, 0)) == -1) || | ((rc = setsockopt (s, SOL_SOCKET, SO_KEEPALIVE, (char*) &opt, sizeof (int))) == -1) || | ((rc = setsockopt (s, IPPROTO_TCP, TCP_KEEPALIVE, (char*) &opt, sizeof (int))) == -1) | ); | } | configure:20326: result: no configure:20472: checking that generated files are newer than configure configure:20478: result: done configure:20545: creating ./config.status ## ---------------------- ## ## Running config.status. ## ## ---------------------- ## This file was extended by zeromq config.status 4.1.4, which was generated by GNU Autoconf 2.69. Invocation command line was CONFIG_FILES = CONFIG_HEADERS = CONFIG_LINKS = CONFIG_COMMANDS = $ ./config.status on 01HW252640 config.status:1228: creating Makefile config.status:1228: creating src/libzmq.pc config.status:1228: creating doc/Makefile config.status:1228: creating builds/msvc/Makefile config.status:1228: creating builds/redhat/zeromq.spec config.status:1228: creating src/platform.hpp config.status:1409: src/platform.hpp is unchanged config.status:1457: executing depfiles commands config.status:1457: executing libtool commands ## ---------------- ## ## Cache variables. ## ## ---------------- ## ac_cv_build=x86_64-unknown-linux-gnu ac_cv_c_compiler_gnu=yes ac_cv_c_const=yes ac_cv_c_inline=inline ac_cv_c_uint32_t=yes ac_cv_c_volatile=yes ac_cv_cxx_compiler_gnu=yes ac_cv_env_ASCIIDOC_set= ac_cv_env_ASCIIDOC_value= ac_cv_env_CCC_set= ac_cv_env_CCC_value= ac_cv_env_CC_set= ac_cv_env_CC_value= ac_cv_env_CFLAGS_set=set ac_cv_env_CFLAGS_value=-gstabs+ ac_cv_env_CPPFLAGS_set= ac_cv_env_CPPFLAGS_value= ac_cv_env_CPP_set= ac_cv_env_CPP_value= ac_cv_env_CXXCPP_set= ac_cv_env_CXXCPP_value= ac_cv_env_CXXFLAGS_set=set ac_cv_env_CXXFLAGS_value=-gstabs+ ac_cv_env_CXX_set= ac_cv_env_CXX_value= ac_cv_env_LDFLAGS_set= ac_cv_env_LDFLAGS_value= ac_cv_env_LIBS_set= ac_cv_env_LIBS_value= ac_cv_env_PKG_CONFIG_LIBDIR_set= ac_cv_env_PKG_CONFIG_LIBDIR_value= ac_cv_env_PKG_CONFIG_PATH_set=set ac_cv_env_PKG_CONFIG_PATH_value=/opt/tangoSoftware/tango9/tango-9.2.2/lib/pkgconfig ac_cv_env_PKG_CONFIG_set= ac_cv_env_PKG_CONFIG_value= ac_cv_env_XMLTO_set= ac_cv_env_XMLTO_value= ac_cv_env_build_alias_set= ac_cv_env_build_alias_value= ac_cv_env_host_alias_set= ac_cv_env_host_alias_value= ac_cv_env_pgm_CFLAGS_set= ac_cv_env_pgm_CFLAGS_value= ac_cv_env_pgm_LIBS_set= ac_cv_env_pgm_LIBS_value= ac_cv_env_sodium_CFLAGS_set= ac_cv_env_sodium_CFLAGS_value= ac_cv_env_sodium_LIBS_set= ac_cv_env_sodium_LIBS_value= ac_cv_env_target_alias_set= ac_cv_env_target_alias_value= ac_cv_func_clock_gettime=yes ac_cv_func_fork=yes ac_cv_func_freeifaddrs=yes ac_cv_func_getifaddrs=yes ac_cv_func_gettimeofday=yes ac_cv_func_memset=yes ac_cv_func_perror=yes ac_cv_func_socket=yes ac_cv_have_decl_LOCAL_PEERCRED=no ac_cv_have_decl_SO_PEERCRED=yes ac_cv_header_alloca_h=yes ac_cv_header_arpa_inet_h=yes ac_cv_header_dlfcn_h=yes ac_cv_header_errno_h=yes ac_cv_header_ifaddrs_h=yes ac_cv_header_inttypes_h=yes ac_cv_header_limits_h=yes ac_cv_header_memory_h=yes ac_cv_header_netinet_in_h=yes ac_cv_header_netinet_tcp_h=yes ac_cv_header_stdbool_h=yes ac_cv_header_stdc=yes ac_cv_header_stddef_h=yes ac_cv_header_stdint_h=yes ac_cv_header_stdlib_h=yes ac_cv_header_string_h=yes ac_cv_header_strings_h=yes ac_cv_header_sys_eventfd_h=yes ac_cv_header_sys_socket_h=yes ac_cv_header_sys_stat_h=yes ac_cv_header_sys_time_h=yes ac_cv_header_sys_types_h=yes ac_cv_header_sys_uio_h=yes ac_cv_header_time=yes ac_cv_header_time_h=yes ac_cv_header_unistd_h=yes ac_cv_host=x86_64-unknown-linux-gnu ac_cv_lib_pthread_pthread_create=yes ac_cv_lib_rt_clock_gettime=yes ac_cv_objext=o ac_cv_path_EGREP='/bin/grep -E' ac_cv_path_FGREP='/bin/grep -F' ac_cv_path_GREP=/bin/grep ac_cv_path_SED=/bin/sed ac_cv_path_ac_pt_PKG_CONFIG=/usr/bin/pkg-config ac_cv_path_install='/usr/bin/install -c' ac_cv_path_mkdir=/bin/mkdir ac_cv_prog_AWK=mawk ac_cv_prog_CPP='gcc -E' ac_cv_prog_CXXCPP='g++ -E' ac_cv_prog_ac_ct_AR=ar ac_cv_prog_ac_ct_CC=gcc ac_cv_prog_ac_ct_CXX=g++ ac_cv_prog_ac_ct_DLLTOOL=dlltool ac_cv_prog_ac_ct_MANIFEST_TOOL=mt ac_cv_prog_ac_ct_OBJDUMP=objdump ac_cv_prog_ac_ct_RANLIB=ranlib ac_cv_prog_ac_ct_STRIP=strip ac_cv_prog_cc_c89= ac_cv_prog_cc_c99= ac_cv_prog_cc_g=yes ac_cv_prog_cxx_g=yes ac_cv_prog_libzmq_have_asciidoc=no ac_cv_prog_libzmq_have_xmlto=no ac_cv_prog_make_make_set=yes ac_cv_type__Bool=no ac_cv_type_signal=void ac_cv_type_size_t=yes ac_cv_type_ssize_t=yes am_cv_CC_dependencies_compiler_type=gcc3 am_cv_CXX_dependencies_compiler_type=gcc3 am_cv_make_support_nested_variables=yes am_cv_prog_cc_c_o=yes am_cv_prog_tar_ustar=gnutar libzmq_cv_c_clang_compiler=no libzmq_cv_c_compiler_works=yes libzmq_cv_c_gcc4_compiler=yes libzmq_cv_c_intel_compiler=no libzmq_cv_c_sun_studio_compiler=no libzmq_cv_check_lang_flag_save_CPPFLAGS='-D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE ' libzmq_cv_cxx_clang_compiler=no libzmq_cv_cxx_compiler_works=yes libzmq_cv_cxx_gcc4_compiler=yes libzmq_cv_cxx_intel_compiler=no libzmq_cv_cxx_strict_flag=-pedantic libzmq_cv_cxx_sun_studio_compiler=no libzmq_cv_cxx_supports_flag__fvisibility_hidden=yes libzmq_cv_cxx_visibility_flag=-fvisibility=hidden libzmq_cv_cxx_wall_flag=-Wall libzmq_cv_cxx_werror_flag=-Werror libzmq_cv_cxx_werror_flag_save= libzmq_cv_have_poller_epoll=yes libzmq_cv_have_poller_kqueue=no libzmq_cv_poller=epoll libzmq_cv_poller_flag=ZMQ_USE_EPOLL libzmq_cv_so_keepalive=yes libzmq_cv_sock_cloexec=yes libzmq_cv_tcp_keepalive=no libzmq_cv_tcp_keepcnt=yes libzmq_cv_tcp_keepidle=yes libzmq_cv_tcp_keepintvl=yes lt_cv_ar_at_file=@ lt_cv_archive_cmds_need_lc=no lt_cv_deplibs_check_method=pass_all lt_cv_file_magic_cmd='$MAGIC_CMD' lt_cv_file_magic_test_file= lt_cv_ld_reload_flag=-r lt_cv_nm_interface='BSD nm' lt_cv_objdir=.libs lt_cv_path_LD=/usr/bin/ld lt_cv_path_LDCXX='/usr/bin/ld -m elf_x86_64' lt_cv_path_NM='/usr/bin/nm -B' lt_cv_path_mainfest_tool=no lt_cv_prog_compiler_c_o=yes lt_cv_prog_compiler_c_o_CXX=yes lt_cv_prog_compiler_pic='-fPIC -DPIC' lt_cv_prog_compiler_pic_CXX='-fPIC -DPIC' lt_cv_prog_compiler_pic_works=yes lt_cv_prog_compiler_pic_works_CXX=yes lt_cv_prog_compiler_rtti_exceptions=no lt_cv_prog_compiler_static_works=yes lt_cv_prog_compiler_static_works_CXX=yes lt_cv_prog_gnu_ld=yes lt_cv_prog_gnu_ldcxx=yes lt_cv_sharedlib_from_linklib_cmd='printf %s\n' lt_cv_shlibpath_overrides_runpath=no lt_cv_sys_global_symbol_pipe='sed -n -e '\''s/^.*[ ]\([ABCDGIRSTW][ABCDGIRSTW]*\)[ ][ ]*\([_A-Za-z][_A-Za-z0-9]*\)$/\1 \2 \2/p'\'' | sed '\''/ __gnu_lto/d'\''' lt_cv_sys_global_symbol_to_c_name_address='sed -n -e '\''s/^: \([^ ]*\)[ ]*$/ {\"\1\", (void *) 0},/p'\'' -e '\''s/^[ABCDGIRSTW]* \([^ ]*\) \([^ ]*\)$/ {"\2", (void *) \&\2},/p'\''' lt_cv_sys_global_symbol_to_c_name_address_lib_prefix='sed -n -e '\''s/^: \([^ ]*\)[ ]*$/ {\"\1\", (void *) 0},/p'\'' -e '\''s/^[ABCDGIRSTW]* \([^ ]*\) \(lib[^ ]*\)$/ {"\2", (void *) \&\2},/p'\'' -e '\''s/^[ABCDGIRSTW]* \([^ ]*\) \([^ ]*\)$/ {"lib\2", (void *) \&\2},/p'\''' lt_cv_sys_global_symbol_to_cdecl='sed -n -e '\''s/^T .* \(.*\)$/extern int \1();/p'\'' -e '\''s/^[ABCDGIRSTW]* .* \(.*\)$/extern char \1;/p'\''' lt_cv_sys_max_cmd_len=1572864 lt_cv_to_host_file_cmd=func_convert_file_noop lt_cv_to_tool_file_cmd=func_convert_file_noop pkg_cv_sodium_CFLAGS=-I/usr/local/include pkg_cv_sodium_LIBS='-L/usr/local/lib -lsodium' ## ----------------- ## ## Output variables. ## ## ----------------- ## ACLOCAL='${SHELL} /opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4/config/missing aclocal-1.14' AMDEPBACKSLASH='\' AMDEP_FALSE='#' AMDEP_TRUE='' AMTAR='$${TAR-tar}' AM_BACKSLASH='\' AM_DEFAULT_V='$(AM_DEFAULT_VERBOSITY)' AM_DEFAULT_VERBOSITY='0' AM_V='$(V)' AR='ar' AS='as' ASCIIDOC='' AUTOCONF='${SHELL} /opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4/config/missing autoconf' AUTOHEADER='${SHELL} /opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4/config/missing autoheader' AUTOMAKE='${SHELL} /opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4/config/missing automake-1.14' AWK='mawk' BUILD_DOC_FALSE='' BUILD_DOC_TRUE='#' BUILD_TIPC_FALSE='' BUILD_TIPC_TRUE='#' CC='gcc' CCDEPMODE='depmode=gcc3' CFLAGS='-gstabs+' CPP='gcc -E' CPPFLAGS='-pedantic -Werror -Wall -D_GNU_SOURCE -D_REENTRANT -D_THREAD_SAFE -DZMQ_USE_EPOLL' CXX='g++' CXXCPP='g++ -E' CXXDEPMODE='depmode=gcc3' CXXFLAGS='-gstabs+' CYGPATH_W='echo' DEFS='-DHAVE_CONFIG_H' DEPDIR='.deps' DLLTOOL='dlltool' DSYMUTIL='' DUMPBIN='' ECHO_C='' ECHO_N='-n' ECHO_T='' EGREP='/bin/grep -E' EXEEXT='' FGREP='/bin/grep -F' GREP='/bin/grep' HAVE_FORK_FALSE='#' HAVE_FORK_TRUE='' HAVE_IPC_PEERCRED_FALSE='#' HAVE_IPC_PEERCRED_TRUE='' HAVE_PGM_FALSE='' HAVE_PGM_TRUE='#' HAVE_SODIUM_FALSE='#' HAVE_SODIUM_TRUE='' INSTALL_DATA='${INSTALL} -m 644' INSTALL_MAN_FALSE='#' INSTALL_MAN_TRUE='' INSTALL_PROGRAM='${INSTALL}' INSTALL_SCRIPT='${INSTALL}' INSTALL_STRIP_PROGRAM='$(install_sh) -c -s' LD='/usr/bin/ld -m elf_x86_64' LDFLAGS='' LIBOBJS='' LIBS='-lrt -lpthread ' LIBTOOL='$(SHELL) $(top_builddir)/libtool' LIBZMQ_EXTRA_CFLAGS='' LIBZMQ_EXTRA_CXXFLAGS='-fvisibility=hidden ' LIBZMQ_EXTRA_LDFLAGS='' LIPO='' LN_S='ln -s' LTLIBOBJS='' LTVER='5:0:0' MAKEINFO='${SHELL} /opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4/config/missing makeinfo' MANIFEST_TOOL=':' MKDIR_P='/bin/mkdir -p' NM='/usr/bin/nm -B' NMEDIT='' OBJDUMP='objdump' OBJEXT='o' ON_ANDROID_FALSE='' ON_ANDROID_TRUE='#' ON_LINUX_FALSE='#' ON_LINUX_TRUE='' ON_MINGW_FALSE='' ON_MINGW_TRUE='#' OTOOL64='' OTOOL='' PACKAGE='zeromq' PACKAGE_BUGREPORT='zeromq-dev@lists.zeromq.org' PACKAGE_NAME='zeromq' PACKAGE_STRING='zeromq 4.1.4' PACKAGE_TARNAME='zeromq' PACKAGE_URL='' PACKAGE_VERSION='4.1.4' PATH_SEPARATOR=':' PKG_CONFIG='/usr/bin/pkg-config' PKG_CONFIG_LIBDIR='' PKG_CONFIG_PATH='/opt/tangoSoftware/tango9/tango-9.2.2/lib/pkgconfig' RANLIB='ranlib' SED='/bin/sed' SET_MAKE='' SHELL='/bin/bash' STRIP='strip' VERSION='4.1.4' XMLTO='' ac_ct_AR='ar' ac_ct_CC='gcc' ac_ct_CXX='g++' ac_ct_DUMPBIN='' am__EXEEXT_FALSE='' am__EXEEXT_TRUE='#' am__fastdepCC_FALSE='#' am__fastdepCC_TRUE='' am__fastdepCXX_FALSE='#' am__fastdepCXX_TRUE='' am__include='include' am__isrc='' am__leading_dot='.' am__nodep='_no' am__quote='' am__tar='tar --format=ustar -chf - "$$tardir"' am__untar='tar -xf -' bindir='${exec_prefix}/bin' build='x86_64-unknown-linux-gnu' build_alias='' build_cpu='x86_64' build_os='linux-gnu' build_vendor='unknown' datadir='${datarootdir}' datarootdir='${prefix}/share' docdir='${datarootdir}/doc/${PACKAGE_TARNAME}' dvidir='${docdir}' exec_prefix='${prefix}' host='x86_64-unknown-linux-gnu' host_alias='' host_cpu='x86_64' host_os='linux-gnu' host_vendor='unknown' htmldir='${docdir}' includedir='${prefix}/include' infodir='${datarootdir}/info' install_sh='${SHELL} /opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4/config/install-sh' libdir='${exec_prefix}/lib' libexecdir='${exec_prefix}/libexec' libzmq_have_asciidoc='no' libzmq_have_xmlto='no' localedir='${datarootdir}/locale' localstatedir='${prefix}/var' mandir='${datarootdir}/man' mkdir_p='$(MKDIR_P)' oldincludedir='/usr/include' pdfdir='${docdir}' pgm_CFLAGS='' pgm_LIBS='' pkgconfigdir='${libdir}/pkgconfig' prefix='/opt/tangoSoftware/tango9/tango-9.2.2/zeromq-4.1.4' program_transform_name='s,x,x,' psdir='${docdir}' sbindir='${exec_prefix}/sbin' sharedstatedir='${prefix}/com' sodium_CFLAGS='-I/usr/local/include' sodium_LIBS='-L/usr/local/lib -lsodium' sysconfdir='${prefix}/etc' target_alias='' ## ----------- ## ## confdefs.h. ## ## ----------- ## /* confdefs.h */ #define PACKAGE_NAME "zeromq" #define PACKAGE_TARNAME "zeromq" #define PACKAGE_VERSION "4.1.4" #define PACKAGE_STRING "zeromq 4.1.4" #define PACKAGE_BUGREPORT "zeromq-dev@lists.zeromq.org" #define PACKAGE_URL "" #define PACKAGE "zeromq" #define VERSION "4.1.4" #define STDC_HEADERS 1 #define HAVE_SYS_TYPES_H 1 #define HAVE_SYS_STAT_H 1 #define HAVE_STDLIB_H 1 #define HAVE_STRING_H 1 #define HAVE_MEMORY_H 1 #define HAVE_STRINGS_H 1 #define HAVE_INTTYPES_H 1 #define HAVE_STDINT_H 1 #define HAVE_UNISTD_H 1 #define HAVE_DLFCN_H 1 #define LT_OBJDIR ".libs/" #define ZMQ_HAVE_LINUX 1 #define HAVE_LIBPTHREAD 1 #define HAVE_LIBRT 1 #define STDC_HEADERS 1 #define HAVE_ERRNO_H 1 #define HAVE_TIME_H 1 #define HAVE_UNISTD_H 1 #define HAVE_LIMITS_H 1 #define HAVE_STDDEF_H 1 #define HAVE_STDLIB_H 1 #define HAVE_STRING_H 1 #define HAVE_ARPA_INET_H 1 #define HAVE_NETINET_TCP_H 1 #define HAVE_NETINET_IN_H 1 #define HAVE_SYS_SOCKET_H 1 #define HAVE_SYS_TIME_H 1 #define HAVE_IFADDRS_H 1 #define ZMQ_HAVE_IFADDRS 1 #define HAVE_SYS_UIO_H 1 #define ZMQ_HAVE_UIO 1 #define HAVE_SYS_EVENTFD_H 1 #define ZMQ_HAVE_EVENTFD 1 #define HAVE_DECL_SO_PEERCRED 1 #define ZMQ_HAVE_SO_PEERCRED 1 #define HAVE_DECL_LOCAL_PEERCRED 0 #define HAVE_STDBOOL_H 1 #define TIME_WITH_SYS_TIME 1 #define HAVE_LIBSODIUM 1 #define RETSIGTYPE void #define HAVE_PERROR 1 #define HAVE_GETTIMEOFDAY 1 #define HAVE_CLOCK_GETTIME 1 #define HAVE_MEMSET 1 #define HAVE_SOCKET 1 #define HAVE_GETIFADDRS 1 #define HAVE_FREEIFADDRS 1 #define HAVE_FORK 1 #define HAVE_ALLOCA_H 1 #define ZMQ_HAVE_SOCK_CLOEXEC 1 #define ZMQ_HAVE_SO_KEEPALIVE 1 #define ZMQ_HAVE_TCP_KEEPCNT 1 #define ZMQ_HAVE_TCP_KEEPIDLE 1 #define ZMQ_HAVE_TCP_KEEPINTVL 1 configure: exit 0