.

Average: 0
Rating Count: 0

Development status: Released, Release: Release_1_5
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/LMScreen
Contact:



Class Description


Tine Camera via pyTine interface (only working in python3)

Families: Acquisition

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
FrameImage: DevDouble
FrameTimeStrScalar: DevString The epoch time at which time the frame was updated
FrameTimeScalar: DevDouble The epoch time at which time the frame was updated.
Max_FPSScalar: DevDouble Set the maximum refresh rate for camera
ROI_HScalar: DevLong ROI height
ROI_WScalar: DevLong ROI width
ROI_YScalar: DevLong y coordinate of left top ROI corner
ROI_XScalar: DevLong x coordinate of left top ROI corner
ValueScalar: DevDouble value to be passed to Sardana
Value_ParameterScalar: DevString which parameter will be use as a ``source`` for Sardana. Can be `max_i`, `max_x`, `max_y`, `com_x`, `com_y`, `fwhm_x`, `fwhm_y`, `sum`
ROI_SUMScalar: DevDouble sum of intensity over ROI
FWHM_YScalar: DevDouble vertical size of peak wihtin ROI
FWHM_XScalar: DevDouble horizontal size of peak wihtin ROI
COM_YScalar: DevDouble y coordinate of ROI`s center of mass
COM_XScalar: DevDouble x coordinate of ROI`s center of mass
Max_IntensityScalar: DevDouble maxumum intensity value in ROI
Max_YScalar: DevDouble y coordinate of intensity maxumum within ROI
Max_XScalar: DevDouble x coordinate of intensity maxumum within ROI
BackgroundSigmasScalar: DevDouble
SubtractBackgroundScalar: DevBoolean

Commands:

Name Description
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.

Pipes:

Properties:

Name Description
RotateDevShort define the rotation angle in 90 deg steps (!!). E.g. Rotate_Angle = 3 means 270 deg rotation
Flip_HDevShort If True - the image will be flipped horizontally
Flip_VDevShort If True - image will be flipped vertically
ScreenDevString LM Screen number: 1, 2, etc.
BeamlineDevString Beamline name: P01, P02, P03, P04, P05, P06, P07, P08, P09, P10, P11, P12, P13, P14, P21a, P21b, P22, P23, P24, P25, P61, P62, P63, P64, P65, P66


Please log in to comment.

6 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Mar 2022, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:5 Mar 2022, 3:58 a.m.