Average: 0
Rating Count: 0

Development status: New development, Release: 1.0
Information status: Updated
Repository: https://github.com/yamedvedya/lm_analysis
Download
Contact:



Class Description


Families: BeamDiagnostics

Key words:

Platform: All Platforms

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
max_xScalar: DevDouble x coordinate of intensity maxumum within ROI
max_yScalar: DevDouble y coordinate of intensity maxumum within ROI
max_intensityScalar: DevDouble maxumum intensity value in ROI
com_xScalar: DevDouble x coordinate of ROI's center of mass
com_yScalar: DevDouble y coordinate of ROI's center of mass
fwhm_xScalar: DevDouble horizontal size of peak wihtin ROI
fwhm_yScalar: DevDouble vertical size of peak wihtin ROI
roi_sumScalar: DevDouble sum of intensity over ROI
scan_parameterScalar: DevString which parameter will be use as a "source" for Sardana. Can be "max_i", "max_x", "max_y", "com_x", "com_y", "fwhm_x", "fwhm_y", "sum"
valueScalar: DevDouble value to be passed to Sardana
roi_xScalar: DevLong x coordinate of left top ROI corner
roi_yScalar: DevDouble y coordinate of left top ROI corner
roi_wScalar: DevDouble ROI width
roi_hScalar: DevDouble ROI height

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
does analysis of last frame
StopInput: DevVoid
Output: DevVoid

Pipes:

Properties:

Name Description
CameraDeviceDevString Adress of related camera tango server


Please log in to comment.

README

b'General info:\r\nThis is small server to do simple analysis of 2d images, which can be taken from the other Tango server, e.g. TTTGW or VimbaViewer.\r\n\r\nThe server is better to use with the CameraViewer utility.\r\n\r\nInstallation:\r\nTo start server the 4 parameters has to be provided:\r\n\r\n"CameraDevice" - the tango address of image source\r\nThe following settings are needed to work with CameraViewer, which update them automatically during start. In case you use server without CameraViewer better to set it to False (or 0) to avoid confusions.\r\n\r\n"Flip_H" - define whether the source picture has to be flipped horizontally. Could be True or False.\r\n"Flip_V" - define whether the source picture has to be flipped vertically. Could be True or False.\r\n"Rotate_Angle" - define the rotation angle in 90 deg steps (!!). E.g. Rotate_Angle = 3 means 270 deg rotation\r\nOperation:\r\nThe analysis is performed in the rectangle, defined by roi_x, roi_y, roi_w, roi_h attributes. In case if the roi_w, roi_h are 0 - the whole picture is analyzed.\r\n\r\nThe following parameters are calculated:\r\n\r\nsum - sum of intensities\r\nmax_intensity - the maximum value\r\nmax_x, max_y - position of center of mass\r\ncom_x, com_y - position of center of mass\r\nfwhm_x, fwhm_y - horizontal and vertical size of half maximum of peak\r\nConnection to Sardana:\r\nThe server has a variable "value" attribute, which can act as a source for the Sardana scans.\r\n\r\nThe parameter, which should be passed to "value", selected by "scan_parameter" attribute. It could be: "max_i", "max_x", "max_y", "com_x", "com_y", "fwhm_x", "fwhm_y", "sum"\r\n\r\nThis is the example of entry to the online.xml, to add server to nxselector :\r\n\r\n<device>\r\n<name>lm4_value</name>\r\n<type>counter</type>\r\n<module>tangoattributectctrl</module>\r\n<device>p23/lmanalysis/lm4/value</device>\r\n<control>tango</control>\r\n<hostname>hasep23oh:10000</hostname>\r\n</device>'

7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You can see previous version here .



7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You can see previous version here .



7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You can see previous version here .



7 Dec 2020, Yury Matveev
Created:
The device class has been added to catalogue.
Added by:ymatveev on:7 Dec 2020, 4:29 p.m.