Average: 0
Rating Count: 0

Development status: New development
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Keithley/Keithley2602Bemu2400
Contact:



Class Description


Class for controlling the Keithley2602B using SCP commands.

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: Keithley

Product:

2602B

Bus: Ethernet

Class interface


Attributes:

Name Description
VoltageScalar: DevDouble
CurrentScalar: DevDouble
SourFuncModeScalar: DevString Selected source. Possible values: VOLTage, CURRent, MEMory
SourCurrModeScalar: DevString DC sourcing mode for I-source. Possible values; FIXed, LIST, SWEep.
SourVoltModeScalar: DevString DC sourcing mode for V-source. Possible values; FIXed, LIST, SWEep.
SourCurrRangeScalar: DevDouble Range for I-source
SensVoltRangeScalar: DevDouble Voltage measurement range.
SourCurrLevelScalar: DevDouble Set I-source amplitude
SourVoltLevelScalar: DevDouble Set V-source amplitude
SensFunctionScalar: DevString Measure function. Possible values: VOLTage or CURRent.
SensCurrProtecScalar: DevDouble Current compliance
SensVoltProtecScalar: DevDouble Voltage compliance
SensCurrRangeScalar: DevDouble Current measurement range
OutputStateScalar: DevLong Output state: 0 -> off, 1 -> on
SourVoltRangeScalar: DevDouble Range for V-source

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
Reset

Pipes:

Properties:

Name Description
SocketDeviceDevString Name of the tango Socket device connecting to the hardware

Class Description


Class for controlling the Keithley2602B using SCP commands.

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: Keithley

Product:

2602B

Bus: Ethernet

Class interface


Attributes:

Name Description
VoltageScalar: DevDouble
CurrentScalar: DevDouble
SourFuncModeScalar: DevString Selected source. Possible values: VOLTage, CURRent, MEMory
SourCurrModeScalar: DevString DC sourcing mode for I-source. Possible values; FIXed, LIST, SWEep.
SourVoltModeScalar: DevString DC sourcing mode for V-source. Possible values; FIXed, LIST, SWEep.
SourCurrRangeScalar: DevDouble Range for I-source
SensVoltRangeScalar: DevDouble Voltage measurement range.
SourCurrLevelScalar: DevDouble Set I-source amplitude
SourVoltLevelScalar: DevDouble Set V-source amplitude
SensFunctionScalar: DevString Measure function. Possible values: VOLTage or CURRent.
SensCurrProtecScalar: DevDouble Current compliance
SensVoltProtecScalar: DevDouble Voltage compliance
SensCurrRangeScalar: DevDouble Current measurement range
OutputStateScalar: DevLong Output state: 0 -> off, 1 -> on
SourVoltRangeScalar: DevDouble Range for V-source

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
Reset

Pipes:

Properties:

Name Description
SocketDeviceDevString Name of the tango Socket device connecting to the hardware


Please log in to comment.

13 Oct 2018, DS Admin
Updated:
A device class has been added.
You can see previous version here .



13 Oct 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:13 Oct 2018, 3:38 a.m.