This is historical information of device classes implemented in AcqPrincetonSwing device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Princeton CCD acquisition device

Families: Acquisition

Key words: 2D

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
acqModeScalar: DevLong
binningSpectrum: DevLong
checkTemperatureScalar: DevBoolean
depthScalar: DevLong
exposureScalar: DevDouble
fileFormatScalar: DevString
fileNameScalar: DevString
fileParmsSpectrum: DevString
framesScalar: DevLong
heightScalar: DevLong
imageImage: DevUShort
nbROIScalar: DevLong
numFrameScalar: DevLong
roiSpectrum: DevLong
roi2Spectrum: DevLong
rotateImageScalar: DevLong
saturationScalar: DevDouble
saturationAlarmScalar: DevDouble
saturationMaxScalar: DevDouble
shutterModeScalar: DevLong
temperatureScalar: DevDouble
timingScalar: DevDouble
triggerScalar: DevLong
useROIScalar: DevBoolean
widthScalar: DevLong
shutterCloseDelayScalar: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
CloseInput: DevVoid
Output: DevVoid
Frees the current camera, prepares it for power-down
GetParamInput: DevString
Output: DevString
None.
OpenInput: DevVoid
Output: DevVoid
Reserves and initializes the camera hardware - Detects the characteristics of the CCD : width, height, depth wich can be read using the device`s attributes - Sets the desired temperature
SetParamInput: DevVarStringArray
Output: DevVoid
None.
StartInput: DevVoid
Output: DevVoid
Starts exposing - the desired exposing mode (continuous or sequence) must be previously defined with SetMode() command
StopInput: DevVoid
Output: DevVoid
Stops the current sequence of exposing

Pipes:

Properties:

Name Description
CamIdDevString Camera identifier
CamTypeDevLong Camera type 0 = Princeton

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:22 Feb 2018, 2:43 p.m.