.

Average: 0
Rating Count: 0

Development status: New development
Information status: New
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Vacuum/BakeOutControlDS
Contact:



Class Description


Families: Vacuum

Key words:

Platform: All Platforms

Language: Python

License:

Contact:

Class interface


Attributes:

Name Description
Temperature_AllSpectrum: DevDouble
Program_7_ZonesSpectrum: DevShort
Temperature_8Scalar: DevDouble
Program_6_ParamsSpectrum: DevDouble
Program_5_ZonesSpectrum: DevShort
Temperature_2Scalar: DevDouble
Temperature_3Scalar: DevDouble
Temperature_1Scalar: DevDouble
Temperature_6Scalar: DevDouble
Output_5_LimitScalar: DevShort
Temperature_4Scalar: DevDouble
Temperature_5Scalar: DevDouble
Program_2_ZonesSpectrum: DevShort
Output_6_LimitScalar: DevShort
PressureScalar: DevDouble
Output_8Scalar: DevShort
Output_4_LimitScalar: DevShort
Program_4_ParamsSpectrum: DevDouble
Program_1_ZonesSpectrum: DevShort
Program_8_ZonesSpectrum: DevShort
Output_3_LimitScalar: DevShort
Output_2_LimitScalar: DevShort
Program_2_ParamsSpectrum: DevDouble
Temperature_SetPointScalar: DevDouble
Temperature_MaxScalar: DevDouble
Program_3_ParamsSpectrum: DevDouble
Pressure_SetPointScalar: DevDouble
Program_3_ZonesSpectrum: DevShort
Program_8_ParamsSpectrum: DevDouble
Output_6Scalar: DevShort
Output_7Scalar: DevShort
Output_4Scalar: DevShort
Output_5Scalar: DevShort
Output_2Scalar: DevShort
Output_3Scalar: DevShort
Output_1Scalar: DevShort
Output_1_LimitScalar: DevShort
Program_1Image: DevDouble
Program_2Image: DevDouble
Program_3Image: DevDouble
Program_4Image: DevDouble
Program_5Image: DevDouble
Program_6Image: DevDouble
Program_7Image: DevDouble
Program_8Image: DevDouble
Temperature_7Scalar: DevDouble
Output_7_LimitScalar: DevShort
Program_1_ParamsSpectrum: DevDouble
Output_8_LimitScalar: DevShort
Program_4_ZonesSpectrum: DevShort
Program_6_ZonesSpectrum: DevShort
Program_5_ParamsSpectrum: DevDouble
Program_7_ParamsSpectrum: DevDouble

Commands:

Name Description
ResetInput: DevVoid
Output: DevVoid
StopInput: DevShort
Output: DevVoid
StartInput: DevShort
Output: DevVoid
CheckStatusInput: DevVoid
Output: DevString
CheckPressureInput: DevVoid
Output: DevDouble
SendCommandInput: DevVarStringArray
Output: DevString

Pipes:

Properties:

Name Description
PressureAttributeDevString
TemperatureSetPointDevDouble
CommsDeviceDevString
ControllerTypeDevString
PressureSetPointDevDouble


Please log in to comment.

16 Jan 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:16 Jan 2018, 1:24 p.m.