Average: 0
Rating Count: 0

Development status: Released, Release: Release_1_0
Information status: New
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/PowerSupply/SerenRXLX01
Contact:



Class Description


SerenRXLX01 radio frequency power supply

Families: PowerSupply

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: http://www.serenips.com/

Bus: Not Applicable

Class interface


Attributes:

Name Description
ControlSourceScalar: DevUShort Sets control source: 0: analogue interface 1: serial interface 2: front panel If set to serial while RF output is enabled and unit is under analogue control RF output will be disabled. If set to serial while RF output is enabled and unit is under front panel control RF output will NOT be disabled.
FrequencyScalar: DevLong Operating frequency in Khz, 1KHz stepsize
ExciterModeScalar: DevBoolean Exciter mode true = MASTER false = SLAVE
PowerLevelingScalar: DevBoolean Select power leveling true = forward false = load
ControlModeScalar: DevUShort Control mode 0 = power control 1 = voltage control 2 = current control (assuming feedback voltage is proportional to current, typically 0.01 VDC = 0.01 A) Unfortunately requesting the state of the attribute from the hardware can only distinguish between power control and voltage control.
VoltageSetPointScalar: DevLong Voltage setpoint in 1 V steps
PulseFrequencyScalar: DevLong Pulse Frequency in Hzin 1 Hz steps
RFOutputScalar: DevBoolean Enable / disable RF output true = enabled false = disabled
RFOutputRampingScalar: DevBoolean Enable / disable RF output ramping true = enabled false = disabled
RFOutputRampDTIntervalScalar: DevLong RF output ramp down time interval in s true = enabled false = disabled
RFOutputRampUTIntervalScalar: DevLong RF output ramp up time interval in s true = enabled false = disabled
ForwardPowerOutputScalar: DevLong

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
BaudRateDevLong baud rate if connected via RS232
ConnectTypeDevString can be `serial`l or `net`
DeviceFileDevString tty device file name if connected via RS232
HostNameDevString Hots name / ip address if connected via terminal server
PortNumberDevUShort Port number if connected via terminal server
SimulationModeDevBoolean


Please log in to comment.

26 Aug 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:26 Aug 2017, 3:03 a.m.