This is historical information of device classes implemented in GpibPrologix device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


communication interface to gpib instruments through Prologix gpib-ethernet controller
Only 1 instrument can be connected to GpibPrologix device

Families: Communication

Key words:

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: GPIB

Class interface


Attributes:

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
WriteInput: DevString
Output: DevVoid
None.
ReadInput: DevVoid
Output: DevString
None.
ReadLongStringInput: DevLong
Output: DevString
None.
WriteReadInput: DevString
Output: DevString
None.
SetTimeOutInput: DevShort
Output: DevVoid
None.
TriggerInput: DevVoid
Output: DevVoid
None.
ClearInput: DevVoid
Output: DevVoid
None.
IsSRQLineUPInput: DevVoid
Output: DevBoolean
returns true if SRQ line is UP, false otherwise

Pipes:

Properties:

Name Description
UrlDevString Name or IP address e.g : gpib1, 172.16.123.123
PortDevShort The IP port default value : 1234
ReadTimeoutDevShort Read Timeout in milliseconds from 1 to 4000 default value : 100
ReadTerminationDevString how read is finished : [TIMEOUT|EOI|TERMINATOR] TIMEOUT : read until timeout EOI : read until instrument marks with EOI the end of message TERMINATOR read until Terminator (the ReadTerminator property) is received Default Value : EOI
ReadTerminatorDevShort the Read Terminator it marks the end of the response of the instrument eg LF = 10, CR = 13
WriteTerminatorDevShort terminators to be written at the end of a command see command eos Prologix removes all not escaped LF,CR, and ESC so if LF or CR or CRLF are waited by the instrument at the end of the command specify it here possible values : 0 (CRLF) 1 (CR) 2 (LF) 3 (NONE) default value : 2 (LF)
GpibAddressDevShort The gpib address (from 0 to 30) default : no default -must be set

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:07 p.m.