Class Description


This is the device server dedicated to the control of the PSS zones of the machine.

Families: Security

Key words:

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
Pss_access_stateScalar: DevShort

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
Init_searchInput: DevVoid
Output: DevVoid
This command sets the PSS to the "search" mode.
Enter_ctrl_accessInput: DevVoid
Output: DevVoid
Enter the "controlled access" mode of the PSS.
Leave_ctrl_accessInput: DevVoid
Output: DevVoid
Leave the "controlled access" mode of the PSS.
Get_itlk_net_dir_nameInput: DevVoid
Output: DevString
This command returns the name of the directory where is located the interlock network file.
Get_itlk_net_file_nameInput: DevVoid
Output: DevString
This command returns the file name of the interlock network file.

Pipes:

Properties:

Name Description
Daresbury_device_nameDevString Device name of the associated Daresbury device server.
Ctrl_access_relay_devname_1DevString Device name of the first ``controlled access`` relay.
Ctrl_access_relay_devname_2DevString Device name of the second ``controlled access`` relay.
Init_search_relay_devname_1DevString Device name of the first ``init search`` relay.
Init_search_relay_devname_2DevString Device name of the second ``init search`` relay.
Search_in_progress_moduleDevShort Module number of the ``search in progress`` relay.
Search_in_progress_bitDevShort Bit number of the ``search in progress`` relay.
Search_complete_moduleDevShort Module number of the ``search complete`` relay.
Search_complete_bitDevShort Bit number of the ``search complete`` relay.
Ctrl_access_moduleDevShort Module number of the ``controlled access`` relay.
Ctrl_access_bitDevShort Bit number of the ``controlled access`` relay.
Itlk_net_dir_nameDevString Name of the directory where is located the interlock network file.
Itlk_net_file_nameDevString Name of the interlock network file.