Average: 0
Rating Count: 0

Development status: Released, Release: Danfysik9000-Release_1_10
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/PowerSupply/Danfysik9000
Contact:



Class Description


Device server to control Danfysik system 9000 power supplies.

Families: PowerSupply

Key words:

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
CurrentScalar: DevDouble
VoltageScalar: DevDouble
CurrentSetPointScalar: DevDouble
MaxCurrentScalar: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
OnInput: DevVoid
Output: DevVoid
Switch powersupply ON.
OffInput: DevVoid
Output: DevVoid
Switch powersupply OFF.
ResetInput: DevVoid
Output: DevVoid
Reset the powersupply to a well known state.
SetCurrentInput: DevVoid
Output: DevVoid
This command will apply the setpoint of the Current Attribute on the channel.
ZeroCurrentInput: DevVoid
Output: DevVoid
This command will set the Current to 0 without losing the set point of the Current Attribute.
RemoteInput: DevVoid
Output: DevVoid
switches the line-in command to the remote operation.
LocalInput: DevVoid
Output: DevVoid
switches the line-in command to the local line.
WriteCmdInput: DevString
Output: DevString
Write the command on the serial line and read the answer.
WriteSetupCommandInput: DevString
Output: DevString
Write the setup command on the serial line and read the answer. The string given in parameter should be the setup command without the ESC< at the begining and without the \\r at the end.

Pipes:

Properties:

Name Description
Ext_itlk_0_descriptionDevString Description of the EXTERNAL INTERLOCK 0. This message will be displayed when this interlock will happen.
Ext_itlk_1_descriptionDevString Description of the EXTERNAL INTERLOCK 1. This message will be displayed when this interlock will happen.
Ext_itlk_2_descriptionDevString Description of the EXTERNAL INTERLOCK 2. This message will be displayed when this interlock will happen.
Ext_itlk_3_descriptionDevString Description of the EXTERNAL INTERLOCK 3. This message will be displayed when this interlock will happen.
Serial_nameDevString Name of the serial line device
AddressDevShort address of the power supply unit when working RS422 multi drop mode.
MaxCurrentDevDouble Maximum authorized (by the power supply) current in remote.
Ext_itlk_0_descriptionDevString Description of the EXTERNAL INTERLOCK 0. This message will be displayed when this interlock will happen.
Ext_itlk_1_descriptionDevString Description of the EXTERNAL INTERLOCK 1. This message will be displayed when this interlock will happen.
Ext_itlk_2_descriptionDevString Description of the EXTERNAL INTERLOCK 2. This message will be displayed when this interlock will happen.
Ext_itlk_3_descriptionDevString Description of the EXTERNAL INTERLOCK 3. This message will be displayed when this interlock will happen.


Please log in to comment.

20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.