Table Of Contents

Previous topic

poolcontainer

Next topic

poolcontrollermanager

This Page

poolcontroller

This module is part of the Python Pool libray. It defines the base classes for

Classes

PoolController

Inheritance diagram of PoolController

class PoolController(**kwargs)[source]

Bases: sardana.pool.poolcontroller.PoolBaseController

Controller class mediator for sardana controller plugins

serialize(*args, **kwargs)[source]
re_init()[source]
get_ctrl_types()[source]
is_online()[source]
get_ctrl()[source]
ctrl

actual controller object

get_ctrl_info()[source]
ctrl_info

controller information object

set_operator(operator)[source]

Defines the current operator object for this controller. For example, in acquisition, it should be a PoolMeasurementGroup object.

Parameters:operator (object) – the new operator object
get_operator()[source]
operator

current controller operator

set_log_level(pool_ctrl, *args, **kwargs)[source]
get_log_level(pool_ctrl, *args, **kwargs)[source]
get_library_name()[source]
get_class_name()[source]
get_axis_attributes(pool_ctrl, *args, **kwargs)[source]
get_ctrl_attr(pool_ctrl, *args, **kwargs)[source]
set_ctrl_attr(pool_ctrl, *args, **kwargs)[source]
get_axis_attr(pool_ctrl, *args, **kwargs)[source]
set_axis_attr(pool_ctrl, *args, **kwargs)[source]
set_ctrl_par(pool_ctrl, *args, **kwargs)[source]
get_ctrl_par(pool_ctrl, *args, **kwargs)[source]
set_axis_par(pool_ctrl, *args, **kwargs)[source]
get_axis_par(pool_ctrl, *args, **kwargs)[source]
raw_read_axis_states(axises=None, ctrl_states=None)[source]

Unsafe method. Reads the state for the given axises. If axises is None, reads the state of all active axises.

Parameters:axises (seq<int> or None) – the list of axis to get the state. Default is None meaning all active axis in this controller
Returns:a tuple of two elements: a map containing the controller state information for each axis and a boolean telling if an error occured
Return type:dict<PoolElement, state info>, bool
read_axis_states(pool_ctrl, *args, **kwargs)[source]

Reads the state for the given axises. If axises is None, reads the state of all active axises.

Parameters:axises (seq<int> or None) – the list of axis to get the state. Default is None meaning all active axis in this controller
Returns:a map containing the controller state information for each axis
Return type:dict<PoolElement, state info>
raw_read_axis_values(axises=None, ctrl_values=None)[source]

Unsafe method. Reads the value for the given axises. If axises is None, reads the value of all active axises.

Parameters:axises (seq<int> or None) – the list of axis to get the value. Default is None meaning all active axis in this controller
Returns:a map containing the controller value information for each axis
Return type:dict<PoolElement, value>
read_axis_values(pool_ctrl, *args, **kwargs)[source]

Reads the value for the given axises. If axises is None, reads the value of all active axises.

Parameters:axises (seq<int> or None) – the list of axis to get the value. Default is None meaning all active axis in this controller
Returns:a map containing the controller value information for each axis
Return type:dict<PoolElement, value>
raw_stop_all()[source]
raw_stop_one(axis)[source]
stop_all(pool_ctrl, *args, **kwargs)[source]
stop(pool_ctrl, *args, **kwargs)
stop_one(pool_ctrl, *args, **kwargs)[source]
stop_axises(pool_ctrl, *args, **kwargs)[source]

Stops the given axises. If axises is None, stops all active axises.

Parameters:axises (seq<int> or None) – the list of axis to stop. Default is None meaning all active axis in this controller
stop_elements(pool_ctrl, *args, **kwargs)[source]

Stops the given elements. If axises is None, stops all active axises.

Parameters:elements – the list of elements to stop. Default is None meaning all active axis in this controller
raw_abort_all()[source]
raw_abort_one(axis)[source]
abort_all(pool_ctrl, *args, **kwargs)[source]
abort_one(pool_ctrl, *args, **kwargs)[source]
abort_axises(pool_ctrl, *args, **kwargs)[source]

Aborts the given axises. If axises is None, aborts all active axises.

Parameters:axises (seq<int> or None) – the list of axis to abort. Default is None meaning all active axis in this controller
abort_elements(pool_ctrl, *args, **kwargs)[source]

Aborts the given elements. If axises is None, aborts all active axises.

Parameters:elements – the list of elements to abort. Default is None meaning all active axis in this controller
abort(pool_ctrl, *args, **kwargs)
emergency_break(pool_ctrl, *args, **kwargs)[source]

Stops the given elements. If axises is None, stops all active axises. If stop raises exception, an abort is attempted.

Parameters:elements – the list of elements to stop. Default is None meaning all active axis in this controller
send_to_controller(pool_ctrl, *args, **kwargs)[source]
raw_move(axis_pos)[source]
move(pool_ctrl, *args, **kwargs)[source]
has_backlash()[source]
wants_rounding()[source]
define_position(pool_ctrl, *args, **kwargs)[source]
write_one(axis, value)[source]

PoolPseudoMotorController

Inheritance diagram of PoolPseudoMotorController

class PoolPseudoMotorController(**kwargs)[source]

Bases: sardana.pool.poolcontroller.PoolController

serialize(*args, **kwargs)[source]
calc_all_pseudo(pool_ctrl, *args, **kwargs)[source]
calc_all_physical(pool_ctrl, *args, **kwargs)[source]
calc_pseudo(pool_ctrl, *args, **kwargs)[source]
calc_physical(pool_ctrl, *args, **kwargs)[source]

PoolPseudoCounterController

Inheritance diagram of PoolPseudoCounterController

class PoolPseudoCounterController(**kwargs)[source]

Bases: sardana.pool.poolcontroller.PoolController

serialize(*args, **kwargs)[source]
calc(pool_ctrl, *args, **kwargs)[source]