Table Of Contents

Previous topic

Welcome to PyTango 7.1 documentation!

Next topic

The Tango Device Python API

This Page

Getting started

Dependencies on other libraries

digraph dependencies {
    size="6,3";
    PyTango     [shape=box,label="PyTango 7.1.0"];
    Python      [shape=box,label="Python >=2.4"];
    boostpython [shape=box,label="boost python"];
    boostp1     [shape=box,label="boost >=1.33"];
    boostp2     [shape=box,label="boost >=1.41"];
    Tango       [shape=box,label="Tango >=7.1"];
    omniORB     [shape=box,label="omniORB >=4"];
    numpy       [shape=box,label="numpy >=1.1.0"];
    PyTango -> Python;
    PyTango -> Tango;
    PyTango -> numpy [style=dotted, label="mandatory in windows"];
    Tango -> omniORB;
    PyTango -> boostpython
    boostpython -> boostp1 [label="if python <2.6.3"];
    boostpython -> boostp2 [label="if python >=2.6.3"];
}

Don’t be scared by the graph. Probably most of the packages are already installed. The current PyTango version has four major dependencies:

plus one optional dependency (activated by default) on:

Note

For the provided windows binary, numpy is MANDATORY!

Installing precompiled binaries

The latest binaries for PyTango can be found at: http://www.tango-controls.org/download under the tango bindings section.

Linux

The PyTango team does not provide a precompiled binary for Linux since this would mean having to provide 12 different binaries: one for each major python version (2.4, 2.5, 2.6, 2.7, 3.0 and 3.1) times 2 for both 32bits and 64bits.

Windows

PyTango team provides a binary PyTango distributable for Windows XP/Vista 32bits for usage with python 2.6.

The binary comes with its’s own boost-python, omniORB and Tango DLLs

version Includes the following DLLs
7.1.0
  • tango 7.1.1 (VC++ 8)
  • omniORB 4.1.4
  • boost python 1.42 (VC++8, multi-threaded)
7.1.0 rc1
  • tango 7.1.1 (VC++ 8)
  • omniORB 4.1.4
  • boost python 1.41 beta 1 (VC++8, multi-threaded) this version was used because it is the first version that fixes a bug that prevents PyTango from being used with python >= 2.6.3

The binary was compiled with numpy dependency therefore you need to have numpy* installed in order to use numpy

Compilation

Linux

Since PyTango 7 the build system used to compile PyTango is the standard python distutils.

Besides the binaries for the four dependencies mentioned above, you also need the development files for the respective libraries.

boost python dependency

PyTango has a dependency on the boost python library (>= 1.33). This means that the shared library file libboost-python.so must be accessible to the compilation command.

Note

If you use python >= 2.6.3 you MUST install boost python >= 1.41

Most linux distributions today provide a boost python package.

Furthermore, in order to be able to build PyTango, you also need the include headers of boost python. They are normaly provided by a package called boost_python-dev.

If, for some reason, you need to compile and install boost python, here is a quick recipie:

  1. Download latest boost tar.gz file and extract it

  2. Download latest bjam (most linux distributions have a bjam package. If not, sourceforge provides a binary for many platforms)

  3. build and/or install:

    1. Simple build: in the root directory where you extracted boost type:

      bjam --with-python toolset=gcc variant=release threading=multi link=shared

      this will produce in bin.v2/libs/python/build/gcc-<gcc_ver>/release/threading-multi a file called libboost_python-gcc<gcc_ver>-mt-<boost_ver>.so.<boost_python_ver>

    2. Install (you may need administrator permissions to do so):

      bjam --with-python toolset=gcc variant=release threading=multi link=shared install

    3. Install in a different directory (<install_dir>):

      bjam --with-python toolset=gcc variant=release threading=multi link=shared install --prefix=<install_dir>

configuration

The second step is to make sure the three/four libraries (omniORB, tango, boost python and/or numpy) are accessible to the compilation command. So, for example, if you installed:

boost python under /home/homer/local

omniORB under /home/homer/local1

tango under /home/homer/local2

numpy under /usr/lib/python2.6/site-packages/numpy

you must export the three environment variables:

export BOOST_ROOT=/home/homer/local
export OMNI_ROOT=/home/homer/local1
export TANGO_ROOT=/home/homer/local2

# in openSUSE 11.1 this is the default base location for the include files
export NUMPY_ROOT=/usr/lib/python2.6/site-packages/numpy/core

(for numpy this is the default base location for the include files. This is distribution dependent. For example, ubuntu places a numpy directory under /usr/include, so exporting NUMPY_ROOT is not necessary for this distribution)

For the libraries that were installed in the default system directory (/usr or /usr/local) the above lines are not necessary.

build & install

Finally:

python setup.py build
sudo python setup.py install

Or if you whish to install in a different directory:

python setup.py build
python setup.py install --prefix=/home/homer/local

Or if you wish to use your own private python distribution:

/home/homer/bin/python setup.py build
/home/homer/bin/python setup.py install

For the last case above don’t forget that boost python should have also been previously compiled with this private python distribution.

test

To test the installation start a python console and type:
>>> import PyTango
>>> print PyTango.Release.version
7.1.0

A quick tour of client binding through real examples

Check PyTango version

Start a python console and type:

1
2
3
4
5
6
7
>>> import PyTango
>>> PyTango.__version__
'7.1.0'
>>> PyTango.__version_number__
710
>>> PyTango.__version_description__
'This version implements the C++ Tango 7.1 API.'

or alternatively:

1
2
3
4
5
6
7
>>> import PyTango
>>> PyTango.Release.version
'7.1.0'
>>> PyTango.Release.version_number
710
>>> PyTango.Release.version_description
'This version implements the C++ Tango 7.1 API.'

Check Tango C++ version

From a client (This is only possible since PyTango 7.0.0)

>>> import PyTango.constants
>>> PyTango.constants.TgLibVers
'7.1.0'

From a server you can alternatively do:

u = PyTango.Util.instance()
tg_cpp_lib_ver = u.get_tango_lib_release()

Test the connection to the Device and get it’s current state

One of the most basic examples is to get a reference to a device and determine if it is running or not:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
from PyTango import *
import sys, os, time

# Protect the script from Exceptions
try:
        # Get proxy on the tangotest1 device
        print "Getting DeviceProxy "
        tangotest = DeviceProxy("tango/tangotest/1")

        # ping it
        print tangotest.ping()

        # get the state
        print tangotest.state()

        # First use the classical command_inout way to execute the DevString command
        # (DevString in this case is a command of the TangoTest device)

        result= tangotest.command_inout("DevString", "First hello to device")
        print "Result of execution of DevString command=", result

        # the same with a Device specific command
        result= tangotest.DevString("Second Hello to device")
        print "Result of execution of DevString command=", result

        # Please note that argin argument type is automagically managed by python
        result= tangotest.DevULong(12456)
        print "Result of execution of Status command=", result

# Catch Tango and Systems  Exceptions
except:
        print "Failed with exception !"
        print sys.exc_info()[0]

Execute commands with scalar arguments on a Device

As you can see in the following example, when scalar types are used, the Tango binding automagically manages the data types, and writing scripts is quite easy:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
from PyTango import *
import sys, os, time

tangotest = DeviceProxy("tango/tangotest/1")

# First use the classical command_inout way to execute the DevString command
# (DevString in this case is a command of the TangoTest device)

result= tangotest.command_inout("DevString", "First hello to device")
print "Result of execution of DevString command=", result

# the same with a Device specific command
result= tangotest.DevString("Second Hello to device")
print "Result of execution of DevString command=", result

# Please note that argin argument type is automagically managed by python
result= tangotest.DevULong(12456)
print "Result of execution of Status command=", result

Execute commands with more complex types

In this case you have to use put your arguments data in the correct python structures:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
from PyTango import *
import sys, os, time

print "Getting DeviceProxy "
tango_test = DeviceProxy("tango/tangotest/1")
# The input argument is a DevVarLongStringArray
# so create the argin variable containing
# an array of longs and an array of strings
argin = ([1,2,3], ["Hello", "TangoTest device"])

result= tango_test.DevVarLongArray(argin)
print "Result of execution of DevVarLongArray command=", result

Reading and writing attributes

Basic read/write attribute operations:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
#Read a scalar attribute
scalar=tangotest.read_attribute("long_scalar")

#Read a spectrum attribute
spectrum=tangotest.read_attribute("double_spectrum")

# Write a scalar attribute
scalar_value = 18
tangotest.write_attribute("long_scalar", scalar_value)

# Write a spectrum attribute
spectrum_value = [1.2, 3.2, 12.3]
tangotest.write_attribute("double_spectrum", spectrum_value)

# Write an image attribute
image_value = [ [1, 2], [3, 4] ]
tangotest.write_attribute("long_image", image_value)

Note that if PyTango is compiled with numpy support the values got when reading a spectrum or an image will be numpy arrays. This results in a faster and more memory efficient PyTango. You can also use numpy to specify the values when writing attributes, especially if you know the exact attribute type.:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
import PyTango, numpy

# Creating an unitialized double spectrum of 1000 elements
spectrum_value = PyTango.numpy_spectrum(PyTango.DevDouble, 1000)

# Creating an spectrum with a range
# Note that I do NOT use PyTango.DevLong here, BUT PyTango.NumpyType.DevLong
# numpy functions do not understand normal python types, so there's a
# translation available in PyTango.NumpyType
spectrum_value = numpy.arange(5, 1000, 2, PyTango.NumpyType.DevLong)

# Creating a 2x2 long image from an existing one
image_value = PyTango.numpy_image(PyTango.DevLong, [[1,2],[3,4]])

Registering devices

Defining devices in the Tango DataBase:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
from PyTango import *
import sys, os, time

#  A reference on the DataBase
db = Database()

# The 3 devices name we want to create
# Note: these 3 devices will be served by the same DServer
new_device_name1="px1/tdl/mouse1"
new_device_name2="px1/tdl/mouse2"
new_device_name3="px1/tdl/mouse3"

# Define the Tango Class served by this  DServer
new_device_info_mouse = DbDevInfo()
new_device_info_mouse._class = "Mouse"
new_device_info_mouse.server = "ds_Mouse/server_mouse"

# add the first device
print "Creation Device:" , new_device_name1
new_device_info_mouse.name = new_device_name1
db.add_device(new_device_info_mouse)

# add the next device
print "Creation Device:" , new_device_name2
new_device_info_mouse.name = new_device_name2
db.add_device(new_device_info_mouse)
# add the third device
print "Creation Device:" , new_device_name3
new_device_info_mouse.name = new_device_name3
db.add_device(new_device_info_mouse)

Setting up Device properties

A more complex example using python subtilities. The following python script example (containing some functions and instructions manipulating a Galil motor axis device server) gives an idea of how the Tango API should be accessed from Python:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
from PyTango import *
import sys, os, time

# connecting to the motor axis device
axis1 = DeviceProxy ("microxas/motorisation/galilbox")

# Getting Device Properties
property_names = ["AxisBoxAttachement",
                  "AxisEncoderType",
                  "AxisNumber",
                  "CurrentAcceleration",
                  "CurrentAccuracy",
                  "CurrentBacklash",
                  "CurrentDeceleration",
                  "CurrentDirection",
                  "CurrentMotionAccuracy",
                  "CurrentOvershoot",
                  "CurrentRetry",
                  "CurrentScale",
                  "CurrentSpeed",
                  "CurrentVelocity",
                  "EncoderMotorRatio",
                  "logging_level",
                  "logging_target",
                  "UserEncoderRatio",
                  "UserOffset"]
axis_properties = axis1.get_property(property_names)
for prop in axis_properties.keys():
    print "%s: %s" % (prop, axis_properties[prop][0])

# Changing Properties
axis_properties["AxisBoxAttachement"] = ["microxas/motorisation/galilbox"]
axis_properties["AxisEncoderType"] = ["1"]
axis_properties["AxisNumber"] = ["6"]
axis1.put_property(axis_properties)

# Reading attributes
att_list = axis.get_attribute_list()
for att in att_list:
    att_val = axis.read_attribute(att)
    print "%s: %s" % (att, att_val.value)

# Changing some attribute values
axis1.write_attribute("AxisBackslash", 0.5)
axis1.write_attribute("AxisDirection", 1.0)
axis1.write_attribute("AxisVelocity", 1000.0)
axis1.write_attribute("AxisOvershoot", 500.0)

# Testing some device commands
pos1=axis1.read_attribute("AxisCurrentPosition")
axis1.command_inout("AxisBackward")
while pos1.value > 1000.0:
    pos1=axis1.read_attribute("AxisCurrentPosition")
    print "position axis 1 = ",pos1.value
axis1.command_inout("AxisStop")

A quick tour of Tango device server binding through an example

To write a tango device server in python, you need to import two modules in your script which are:

  1. The PyTango module
  2. The python sys module provided in the classical python distribution

The following in the python script for a Tango device server with two commands and two attributes. The commands are:

  1. IOLOng which receives a Tango Long and return it multiply by 2. This command is allowed only if the device is in the ON state.
  2. IOStringArray which receives an array of Tango strings and which returns it but in the reverse order. This command is only allowed if the device is in the ON state.

The attributes are:

  1. Long_attr wich is a Tango long attribute, Scalar and Read only with a minimum alarm set to 1000 and a maximum alarm set to 1500
  2. Short_attr_rw which is a Tango short attribute, Scalar and Read/Write

The following code is the complete device server code:

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
import PyTango
import sys

class PyDsExp(PyTango.Device_3Impl):

    def __init__(self,cl,name):
        PyTango.Device_3Impl.__init__(self,cl,name)
        self.debug_stream('In PyDsExp __init__')
        PyDsExp.init_device(self)

    def init_device(self):
        self.debug_stream('In Python init_device method')
        self.set_state(PyTango.DevState.ON)
        self.attr_short_rw = 66
        self.attr_long = 1246

#------------------------------------------------------------------

    def delete_device(self):
        self.debug_stream('[delete_device] for device %s ' % self.get_name())

#------------------------------------------------------------------
# COMMANDS
#------------------------------------------------------------------

    def is_IOLong_allowed(self):
        return self.get_state() == PyTango.DevState.ON

    def IOLong(self, in_data):
        self.debug_stream('[IOLong::execute] received number %s' % str(in_data))
        in_data = in_data * 2;
        self.debug_stream('[IOLong::execute] return number %s' % str(in_data))
        return in_data;

#------------------------------------------------------------------

    def is_IOStringArray_allowed(self):
        return self.get_state() == PyTango.DevState.ON

    def IOStringArray(self, in_data):
        l = range(len(in_data)-1, -1, -1);
        out_index=0
        out_data=[]
        for i in l:
            self.debug_stream('[IOStringArray::execute] received String' % in_data[out_index])
            out_data.append(in_data[i])
            self.debug_stream('[IOStringArray::execute] return String %s' %out_data[out_index])
            out_index += 1
        self.y = out_data
        return out_data

#------------------------------------------------------------------
# ATTRIBUTES
#------------------------------------------------------------------

    def read_attr_hardware(self, data):
        self.debug_stream('In read_attr_hardware')

#------------------------------------------------------------------

    def read_Long_attr(self, the_att):
        self.debug_stream('[PyDsExp::read_attr] attribute name Long_attr')

        # Before PyTango 7.0.0
        #PyTango.set_attribute_value(the_att, self.attr_long)

        # Now:
        the_att.set_value(self.attr_long)

#------------------------------------------------------------------

    def read_Short_attr_rw(self, the_att):
        self.debug_stream('[PyDsExp::read_attr] attribute name Short_attr_rw')

        # Before PyTango 7.0.0
        #PyTango.set_attribute_value(the_att, self.attr_short_rw)

        # Now:
        the_att.set_value(self.attr_short_rw)

#------------------------------------------------------------------

    def write_Short_attr_rw(self, the_att):
        self.debug_stream('In write_Short_attr_rw for attribute %s' % the_att.get_name())

        # Before PyTango 7.0.0
        #data = []
        #PyTango.get_write_value(the_att, data)

        # Now:
        data = the_att.get_write_value()
        self.attr_short_rw = data[0]

#------------------------------------------------------------------
# CLASS
#------------------------------------------------------------------

class PyDsExpClass(PyTango.DeviceClass):

    def __init__(self, name):
        PyTango.DeviceClass.__init__(self, name)
        self.set_type("TestDevice")
        print 'In PyDsExpClass __init__'

    cmd_list = { 'IOLong' : [ [ PyTango.ArgType.DevLong, "Number" ],
                              [ PyTango.ArgType.DevLong, "Number * 2" ] ],
                 'IOStringArray' : [ [ PyTango.ArgType.DevVarStringArray, "Array of string" ],
                                     [ PyTango.ArgType.DevVarStringArray, "This reversed array"] ],
    }

    attr_list = { 'Long_attr' : [ [ PyTango.ArgType.DevLong ,
                                    PyTango.AttrDataFormat.SCALAR ,
                                    PyTango.AttrWriteType.READ],
                                  { 'min alarm' : 1000, 'max alarm' : 1500 } ],

                 'Short_attr_rw' : [ [ PyTango.ArgType.DevShort,
                                       PyTango.AttrDataFormat.SCALAR,
                                       PyTango.AttrWriteType.READ_WRITE ] ]
    }

if __name__ == '__main__':
    try:
        py = PyTango.Util(sys.argv)
        py.add_TgClass(PyDsExpClass, PyDsExp, 'PyDsExp')
        U = PyTango.Util.instance()
        U.server_init()
        U.server_run()
    except PyTango.DevFailed,e:
        print '-------> Received a DevFailed exception:',e
    except Exception,e:
        print '-------> An unforeseen exception occured....',e