This class is a used to store TANGO device server process data and to provide the user with a set of utilities method.
This class is implemented using the singleton design pattern. Therefore a device server process can have only one instance of this class and its constructor is not public.
- Example:
- util = PyTango.Util.instance() print util.get_host_name()
Register a new C++ tango class. :Example:
if there is a shared library file called MotorClass.so which contains a MotorClass class and a _create_MotorClass_class method: util.add_Cpp_TgClass('MotorClass', 'Motor')
Note: the parameter ‘device_class_name’ must match the shared library name.
Register a new python tango class. :Example: util.add_TgClass(MotorClass, Motor, ‘Motor’)
connect_db (self) -> None
Connect the process to the TANGO database. If the connection to the database failed, a message is displayed on the screen and the process is aborted
Parameters: None Return: None
get_class_list (self) -> seq
Returns a list of objects of inheriting from DeviceClass
Parameters: None Return: (seq) a list of objects of inheriting from DeviceClass
get_device_by_name (self, name) -> DeviceImpl
Returns the DeviceImpl for the given device name
Parameters:
name: (str) tango device name Return: (DeviceImpl) the DeviceImpl for the given device name
Throws: DevFailed if the tango device name was not found
get_device_list_by_class (self, name) -> seq
Returns a list of objects of inheriting from DeviceImpl for the given Tango class
Parameters:
name: (str) tango class name Return: (seq) a list of objects of inheriting from DeviceImpl for the given Tango class
Throws: DevFailed if the Tango class was not found
get_ds_exec_name (self) -> str
Get a COPY of the device server executable name.
Parameters: None Return: (str) a COPY of the device server executable name. New in PyTango 3.0.4
get_ds_inst_name (self) -> str
Get a COPY of the device server instance name.
Parameters: None Return: (str) a COPY of the device server instance name. New in PyTango 3.0.4
get_ds_name (self) -> str
Get the device server name. The device server name is the <device server executable name>/<the device server instance name>
Parameters: None Return: (str) device server name New in PyTango 3.0.4
get_dserver_device (self) -> DServer
Get a reference to the dserver device attached to the device server process.
Parameters: None Return: (DServer) the dserver device attached to the device server process New in PyTango 7.0.0
get_host_name (self) -> str
Get the host name where the device server process is running.
Parameters: None Return: (str) the host name where the device server process is running New in PyTango 3.0.4
get_pid (self) -> TangoSys_Pid
Get the device server process identifier.
Parameters: None Return: (int) the device server process identifier
get_pid_str (self) -> str
Get the device server process identifier as a string.
Parameters: None Return: (str) the device server process identifier as a string New in PyTango 3.0.4
get_polling_threads_pool_size (self) -> int
Get the polling threads pool size.
Parameters: None Return: (int) the maximun number of threads in the polling threads pool
get_serial_model (self) -> SerialModel
Get the serialization model.
Parameters: None Return: (SerialModel) the serialization model
get_server_version (self) -> str
Get the device server version.
Parameters: None Return: (str) the device server version.
get_tango_lib_release (self) -> int
Get the TANGO library version number.
Parameters: None Return: (int) The Tango library release number coded in 3 digits (for instance 550,551,552,600,....)
get_trace_level (self) -> int
Get the process trace level.
Parameters: None Return: (int) the process trace level.
get_version_str (self) -> str
Get the IDL TANGO version.
Parameters: None Return: (str) the IDL TANGO version. New in PyTango 3.0.4
reset_filedatabase (self) -> None
Reread the file database.
Parameters: None Return: None
server_init (self, with_window = False) -> None
Initialize all the device server pattern(s) embedded in a device server process.
Parameters:
with_window: (bool) default value is False Return: None
Throws: DevFailed If the device pattern initialistaion failed
server_run (self) -> None
Run the CORBA event loop. This method runs the CORBA event loop. For UNIX or Linux operating system, this method does not return. For Windows in a non-console mode, this method start a thread which enter the CORBA event loop.
Parameters: None Return: None
set_polling_threads_pool_size (self, thread_nb) -> None
Set the polling threads pool size.
Parameters:
thread_nb: (int) the maximun number of threads in the polling threads pool Return: None
New in PyTango 7.0.0
set_serial_model (self, ser) -> None
Set the serialization model.
Parameters:
ser: (SerialModel) the new serialization model. The serialization model must be one of BY_DEVICE, BY_CLASS, BY_PROCESS or NO_SYNC Return: None
set_server_version (self, vers) -> None
Set the device server version.
Parameters:
vers: (str) the device server version Return: None
set_trace_level (self, level) -> None
Set the process trace level.
Parameters:
level: (int) the new process level Return: None
trigger_attr_polling (self, dev, name) -> None
Trigger polling for polled attribute. This method send the order to the polling thread to poll one object registered with an update period defined as “externally triggerred”
Parameters:
dev: (DeviceImpl) the TANGO device name: (str) the attribute name which must be polled Return: None
trigger_cmd_polling (self, dev, name) -> None
Trigger polling for polled command. This method send the order to the polling thread to poll one object registered with an update period defined as “externally triggerred”
Parameters:
dev: (DeviceImpl) the TANGO device name: (str) the command name which must be polled Return: None
Throws: DevFailed If the call failed
unregister_server (self) -> None
Unregister a device server process from the TANGO database.
Parameters: None Return: None