This class represents a Tango writable attribute.
get_assoc (self) -> str
Get the associated name.
Parameters: None Return: (bool) the associated name
get_class_properties (self) -> sequence<AttrProperty>
Get the class level attribute properties
Parameters: None Return: (sequence<AttrProperty>) the class attribute properties
get_disp_level (self) -> DispLevel
Get the attribute display level
Parameters: None Return: (DispLevel) the attribute display level
get_format (self) -> AttrDataFormat
Get the attribute format
Parameters: None Return: (AttrDataFormat) the attribute format
get_memorized (self) -> bool
Determine if the attribute is memorized or not.
Parameters: None Return: (bool) True if the attribute is memorized
get_memorized_init (self) -> bool
Determine if the attribute is written at startup from the memorized value if it is memorized
Parameters: None Return: (bool) True if initialized with memorized value or not
get_name (self) -> str
Get the attribute name.
Parameters: None Return: (str) the attribute name
get_polling_period (self) -> int
Get the polling period (mS)
Parameters: None Return: (int) the polling period (mS)
get_type (self) -> int
Get the attribute data type
Parameters: None Return: (int) the attribute data type
get_user_default_properties (self) -> sequence<AttrProperty>
Get the user default attribute properties
Parameters: None Return: (sequence<AttrProperty>) the user default attribute properties
get_writable (self) -> AttrWriteType
Get the attribute write type
Parameters: None Return: (AttrWriteType) the attribute write type
is_archive_event (self) -> bool
Check if the archive event is fired manually for this attribute.
Parameters: None Return: (bool) true if a manual fire archive event is implemented.
is_assoc (self) -> bool
Determine if it is assoc.
Parameters: None Return: (bool) if it is assoc
is_change_event (self) -> bool
Check if the change event is fired manually for this attribute.
Parameters: None Return: (bool) true if a manual fire change event is implemented.
is_check_archive_criteria (self) -> bool
Check if the archive event criteria should be checked when firing the event manually.
Parameters: None Return: (bool) true if a archive event criteria will be checked.
is_check_change_criteria (self) -> bool
Check if the change event criteria should be checked when firing the event manually.
Parameters: None Return: (bool) true if a change event criteria will be checked.
set_archive_event (self) -> None
Set a flag to indicate that the server fires archive events manually without the polling to be started for the attribute If the detect parameter is set to true, the criteria specified for the archive event are verified and the event is only pushed if they are fullfilled.
If detect is set to false the event is fired without checking!
Parameters:
implemented: (bool) True when the server fires change events manually. detect: (bool) Triggers the verification of the archive event properties when set to true. Return: None
set_change_event (self, implemented, detect) -> None
Set a flag to indicate that the server fires change events manually without the polling to be started for the attribute. If the detect parameter is set to true, the criteria specified for the change event are verified and the event is only pushed if they are fullfilled.
If detect is set to false the event is fired without checking!
Parameters:
implemented: (bool) True when the server fires change events manually. detect: (bool) Triggers the verification of the change event properties when set to true. Return: None
set_class_properties (self, props) -> None
Set the class level attribute properties
Parameters:
props: (StdAttrPropertyVector) new class level attribute properties Return: None
set_default_properties (self) -> None
Set default attribute properties.
Parameters:
attr_prop: (UserDefaultAttrProp) the user default property class Return: None
set_disp_level (self, disp_lelel) -> None
Set the attribute display level.
Parameters:
disp_level: (DispLevel) the new display level Return: None
set_memorized (self) -> None
Set the attribute as memorized in database (only for scalar and writable attribute) With no argument the setpoint will be written to the attribute during initialisation!
Parameters: None Return: None
set_memorized_init (self, write_on_init) -> None
Set the initialisation flag for memorized attributes true = the setpoint value will be written to the attribute on initialisation false = only the attribute setpoint is initialised. No action is taken on the attribute
Parameters:
write_on_init: (bool) if true the setpoint value will be written to the attribute on initialisation Return: None
set_polling_period (self, period) -> None
Set the attribute polling update period.
Parameters:
period: (int) the attribute polling period (in mS) Return: None
This class represents a Tango attribute.
check_alarm (self) -> bool
Check if the attribute read value is below/above the alarm level.
Parameters: None Return: (bool) true if the attribute is in alarm condition. Throws: DevFailed If no alarm level is defined.
get_assoc_ind (self) -> int
Get index of the associated writable attribute.
Parameters: None Return: (int) the index in the main attribute vector of the associated writable attribute
get_assoc_name (self) -> str
Get name of the associated writable attribute.
Parameters: None Return: (str) the associated writable attribute name
get_data_format (self) -> AttrDataFormat
Get attribute data format.
Parameters: None Return: (AttrDataFormat) the attribute data format
get_data_size (self) -> None
Get attribute data size.
Parameters: None Return: (int) the attribute data size
get_data_type (self) -> int
Get attribute data type.
Parameters: None Return: (int) the attribute data type
get_date (self) -> TimeVal
Get a COPY of the attribute date.
Parameters: None Return: (TimeVal) the attribute date
get_label (self, ) -> str
Get attribute label property.
Parameters: None Return: (str) he attribute label
get_max_dim_x (self) -> int
Get attribute maximum data size in x dimension.
Parameters: None Return: (int) the attribute maximum data size in x dimension. Set to 1 for scalar attribute
get_max_dim_y (self) -> int
Get attribute maximum data size in y dimension.
Parameters: None Return: (int) the attribute maximum data size in y dimension. Set to 0 for scalar attribute
get_name (self) -> str
Get attribute name.
Parameters: None Return: (str) The attribute name
get_polling_period (self) -> int
Get attribute polling period.
Parameters: None Return: (int) The attribute polling period in mS. Set to 0 when the attribute is not polled
get_quality (self) -> AttrQuality
Get a COPY of the attribute data quality.
Parameters: None Return: (AttrQuality) the attribute data quality
get_writable (self) -> AttrWriteType
Get the attribute writable type (RO/WO/RW).
Parameters: None Return: (AttrWriteType) The attribute write type.
get_x (self) -> int
Get attribute data size in x dimension.
Parameters: None Return: (int) the attribute data size in x dimension. Set to 1 for scalar attribute
get_y (self) -> int
Get attribute data size in y dimension.
Parameters: None Return: (int) the attribute data size in y dimension. Set to 1 for scalar attribute
is_max_alarm (self) -> bool
Check if the attribute is in maximum alarm condition.
Parameters: None Return: (bool) true if the attribute is in alarm condition (read value above the max. alarm).
is_max_warning (self) -> bool
Check if the attribute is in maximum warning condition.
Parameters: None Return: (bool) true if the attribute is in warning condition (read value above the max. warning).
is_min_alarm (self) -> bool
Check if the attribute is in minimum alarm condition.
Parameters: None Return: (bool) true if the attribute is in alarm condition (read value below the min. alarm).
is_min_warning (self) -> bool
Check if the attribute is in minimum warning condition.
Parameters: None Return: (bool) true if the attribute is in warning condition (read value below the min. warning).
is_polled (self) -> bool
Check if the attribute is polled.
Parameters: None Return: (bool) true if the attribute is polled.
is_rds_alarmself) -> bool
Check if the attribute is in RDS alarm condition.
Parameters: None Return: (bool) true if the attribute is in RDS condition (Read Different than Set).
is_write_associated (self) -> bool
Check if the attribute has an associated writable attribute.
Parameters: None Return: (bool) True if there is an associated writable attribute
set_assoc_ind (self, index) -> None
Set index of the associated writable attribute.
Parameters:
index: (int) The new index in the main attribute vector of the associated writable attribute Return: None
set_date (self, new_date) -> None
Set attribute date.
Parameters:
new_date: (TimeVal) the attribute date Return: None
set_quality (self, quality, send_event=False) -> None
Set attribute data quality.
Parameters:
quality: (AttrQuality) the new attribute data quality send_event: (bool) true if a change event should be sent. Default is false. Return: None
set_value (self, data, dim_x = 1, dim_y = 0) -> None
set_value (self, str_data, data) -> None
Set internal attribute value. This method stores the attribute read value inside the object. This method also stores the date when it is called and initializes the attribute quality factor.
Parameters:
data: the data to be set. Data must be compatible with the attribute type and format. for SPECTRUM and IMAGE attributes, data can be any type of sequence of elements compatible with the attribute type str_data: (str) special variation for DevEncoded data type. In this case ‘data’ must also be a str. dim_x: (int) the attribute x length. Default value is 1 dim_y: (int) the attribute y length. Default value is 0 Return: None
set_value_date_quality (self, data, time_stamp, quality, dim_x = 1, dim_y = 0) -> None
set_value_date_quality (self, str_data, data, time_stamp, quality) -> None
Set internal attribute value, date and quality factor. This method stores the attribute read value, the date and the attribute quality factor inside the object.
Parameters:
data: the data to be set. Data must be compatible with the attribute type and format. for SPECTRUM and IMAGE attributes, data can be any type of sequence of elements compatible with the attribute type str_data: (str) special variation for DevEncoded data type. In this case ‘data’ must also be a str. dim_x: (int) the attribute x length. Default value is 1 dim_y: (int) the attribute y length. Default value is 0 time_stamp: (double) the time stamp quality: (AttrQuality) the attribute quality factor Return: None
This class represents a Tango writable attribute.
get_max_value (self) -> obj
Get attribute maximum value or throws an exception if the attribute does not have a maximum value.
Parameters: None Return: (obj) an object with the python maximum value
get_min_value (self) -> obj
Get attribute minimum value or throws an exception if the attribute does not have a minimum value.
Parameters: None Return: (obj) an object with the python minimum value
get_write_value (self, lst) -> None
get_write_value (self) -> obj
Retrieve the new value for writable attribute.
Parameters:
lst: [out] (list) a list object that will be filled with the attribute write value (DEPRECATED) Return: (obj) the attribute write value.
get_write_value_length (self) -> int
Retrieve the new value length (data number) for writable attribute.
Parameters: None Return: (int) the new value data length
is_max_value (self, ) -> bool
Check if the attribute has a maximum value.
Parameters: None Return: (bool) true if the attribute has a maximum value defined
is_min_value (self) -> bool
Check if the attribute has a minimum value.
Parameters: None Return: (bool) true if the attribute has a minimum value defined
set_max_value (self, data) -> None
Set attribute maximum value.
Parameters:
data: the attribute maximum value. python data type must be compatible with the attribute data format and type. Return: None
set_min_value (self, data) -> None
Set attribute minimum value.
Parameters:
data: the attribute minimum value. python data type must be compatible with the attribute data format and type. Return: None
There is one instance of this class for each device. This class is mainly an aggregate of Attribute or WAttribute objects. It eases management of multiple attributes
check_alarm (self) -> bool
check_alarm (self, attr_name) -> bool
check_alarm (self, ind) -> bool
- The 1st version of the method checks alarm on all attribute(s) with an alarm defined.
- The 2nd version of the method checks alarm for one attribute with a given name.
- The 3rd version of the method checks alarm for one attribute from its index in the main attributes vector.
Parameters:
attr_name: (str) attribute name ind: (int) the attribute index Return: (bool) True if at least one attribute is in alarm condition
Throws: DevFailed If at least one attribute does not have any alarm level defined
New in PyTango 7.0.0
get_attr_by_ind (self, ind) -> Attribute
Get Attribute object from its index. This method returns an Attribute object from the index in the main attribute vector.
Parameters:
ind: (int) the attribute index Return: (Attribute) the attribute object
get_attr_by_name (self, attr_name) -> Attribute
Get Attribute object from its name. This method returns an Attribute object with a name passed as parameter. The equality on attribute name is case independant.
Parameters:
attr_name: (str) attribute name Return: (Attribute) the attribute object
Throws: DevFailed If the attribute is not defined.
get_attr_ind_by_name (self, attr_name) -> int
Get Attribute index into the main attribute vector from its name. This method returns the index in the Attribute vector (stored in the MultiAttribute object) of an attribute with a given name. The name equality is case independant.
Parameters:
attr_name: (str) attribute name Return: (int) the attribute index
Throws: DevFailed If the attribute is not found in the vector.
New in PyTango 7.0.0
get_attr_nb (self) -> int
Get attribute number.
Parameters: None Return: (int) the number of attributes New in PyTango 7.0.0
get_w_attr_by_ind (self, ind) -> WAttribute
Get a writable attribute object from its index. This method returns an WAttribute object from the index in the main attribute vector.
Parameters:
ind: (int) the attribute index Return: (WAttribute) the attribute object
get_w_attr_by_name (self, attr_name) -> WAttribute
Get a writable attribute object from its name. This method returns an WAttribute object with a name passed as parameter. The equality on attribute name is case independant.
Parameters:
attr_name: (str) attribute name Return: (WAttribute) the attribute object
Throws: DevFailed If the attribute is not defined.
read_alarm (self, status) -> None
Add alarm message to device status. This method add alarm mesage to the string passed as parameter. A message is added for each attribute which is in alarm condition
Parameters:
status: (str) a string (should be the device status) Return: None
New in PyTango 7.0.0
User class to set attribute default properties. This class is used to set attribute default properties. Three levels of attributes properties setting are implemented within Tango. The highest property setting level is the database. Then the user default (set using this UserDefaultAttrProp class) and finally a Tango library default value
set_abs_change (self, def_abs_change) -> None
Set default change event abs_change property.
Parameters:
def_abs_change: (str) the user default change event abs_change property Return: None
set_archive_abs_change (self, def_archive_abs_change) -> None
Set default archive event abs_change property.
Parameters:
def_archive_abs_change: (str) the user default archive event abs_change property Return: None
set_archive_period (self, def_archive_period) -> None
Set default archive event period property.
Parameters:
def_archive_period: (str) t Return: None
set_archive_rel_change (self, def_archive_rel_change) -> None
Set default archive event rel_change property.
Parameters:
def_archive_rel_change: (str) the user default archive event rel_change property Return: None
set_delta_t (self, def_delta_t) -> None
Set default RDS alarm delta_t property.
Parameters:
def_delta_t: (str) the user default RDS alarm delta_t property Return: None
set_delta_val (self, def_delta_val) -> None
Set default RDS alarm delta_val property.
Parameters:
def_delta_val: (str) the user default RDS alarm delta_val property Return: None
set_description (self, def_description) -> None
Set default description property.
Parameters:
def_description: (str) the user default description property Return: None
set_display_unit (self, def_display_unit) -> None
Set default display unit property.
Parameters:
def_display_unit: (str) the user default display unit property Return: None
set_format (self, def_format) -> None
Set default format property.
Parameters:
def_format: (str) the user default format property Return: None
set_label (self, def_label) -> None
Set default label property.
Parameters:
def_label: (str) the user default label property Return: None
set_max_alarm (self, def_max_alarm) -> None
Set default max_alarm property.
Parameters:
def_max_alarm: (str) the user default max_alarm property Return: None
set_max_value (self, def_max_value) -> None
Set default max_value property.
Parameters:
def_max_value: (str) the user default max_value property Return: None
set_max_warning (self, def_max_warning) -> None
Set default max_warning property.
Parameters:
def_max_warning: (str) the user default max_warning property Return: None
set_min_alarm (self, def_min_alarm) -> None
Set default min_alarm property.
Parameters:
def_min_alarm: (str) the user default min_alarm property Return: None
set_min_value (self, def_min_value) -> None
Set default min_value property.
Parameters:
def_min_value: (str) the user default min_value property Return: None
set_min_warning (self, def_min_warning) -> None
Set default min_warning property.
Parameters:
def_min_warning: (str) the user default min_warning property Return: None
set_period (self, def_period) -> None
Set default periodic event period property.
Parameters:
def_period: (str) the user default periodic event period property Return: None
set_rel_change (self, def_rel_change) -> None
Set default change event rel_change property.
Parameters:
def_rel_change: (str) the user default change event rel_change property Return: None
set_standard_unit (self, def_standard_unit) -> None
Set default standard unit property.
Parameters:
def_standard_unit: (str) the user default standard unit property Return: None
set_unit (self, def_unit) -> None
Set default unit property.
Parameters:
def_unit: (str) te user default unit property Return: None