Bases: PyTango._PyTango.Connection
DeviceProxy is the high level Tango object which provides the client with an easy-to-use interface to TANGO devices. DeviceProxy provides interfaces to all TANGO Device interfaces.The DeviceProxy manages timeouts, stateless connections and reconnection if the device server is restarted. To create a DeviceProxy, a Tango Device name must be set in the object constructor.
add_logging_target (self, target_type_target_name) -> None
Adds a new logging target to the device.
The target_type_target_name input parameter must follow the format: target_type::target_name. Supported target types are: console, file and device. For a device target, the target_name part of the target_type_target_name parameter must contain the name of a log consumer device (as defined in A.8). For a file target, target_name is the full path to the file to log to. If omitted, the device’s name is used to build the file name (which is something like domain_family_member.log). Finally, the target_name part of the target_type_target_name input parameter is ignored in case of a console target and can be omitted.
Parameters:
target_type_target_name: (str) logging target Return: None
Throws: DevFailed from device
New in PyTango 7.0.0
adm_name (self) -> str
Return the name of the corresponding administrator device. This is useful if you need to send an administration command to the device server, e.g restart itNew in PyTango 3.0.4
alias (self) -> str
Return the device alias if one is defined. Otherwise, throws exception.
attribute_history (self, attr_name, depth, extract_as=ExtractAs.Numpy) -> sequence<DeviceAttributeHistory>
Retrieve attribute history from the attribute polling buffer. See chapter on Advanced Feature for all details regarding polling
Parameters:
attr_name: (str) Attribute name. depth: (int) The wanted history depth. extract_as: (DeviceAttribute.ExtractAs) Return: This method returns a vector of DeviceAttributeHistory types.
Throws: NonSupportedFeature, ConnectionFailed, CommunicationFailed, DevFailed from device
attribute_list_query (self) -> sequence<AttributeInfo>
Query the device for info on all attributes. This method returns a sequence of PyTango.AttributeInfo.
Parameters: None Return: (sequence<AttributeInfo>) containing the attributes configuration Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
attribute_list_query_ex (self) -> sequence<AttributeInfoEx>
Query the device for info on all attributes. This method returns a sequence of PyTango.AttributeInfoEx.
Parameters: None Return: (sequence<AttributeInfoEx>) containing the attributes configuration Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
attribute_query (self, attr_name) -> AttributeInfoEx
Query the device for information about a single attribute.
Parameters:
attr_name: (str) the attribute name Return: (AttributeInfoEx) containing the attribute configuration
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
black_box (self, n) -> sequence<str>
Get the last commands executed on the device server
Parameters:
n: n number of commands to get Return: (sequence<str>) sequence of strings containing the date, time, command and from which client computer the command was executed
Example: print black_box(4)
cancel_all_polling_asynch_request (self) -> None
Cancel all running asynchronous request
This is a client side call. Obviously, the calls cannot be aborted while it is running in the device.
Parameters: None Return: None New in PyTango 7.0.0
cancel_asynch_request (self, id ) -> None
Cancel a running asynchronous request
This is a client side call. Obviously, the call cannot be aborted while it is running in the device.
Parameters:
id: The asynchronous call identifier Return: None
New in PyTango 7.0.0
command_history (self, cmd_name, depth) -> sequence<DeviceDataHistory>
Retrieve command history from the command polling buffer. See chapter on Advanced Feature for all details regarding polling
Parameters:
cmd_name: (str) Command name. depth: (int) The wanted history depth. Return: This method returns a vector of DeviceDataHistory types.
Throws: NonSupportedFeature, ConnectionFailed, CommunicationFailed, DevFailed from device
command_inout ( self, cmd_name, cmd_param=None) -> any
Execute a command on a device.
Parameters:
cmd_name: (str) Command name. cmd_param: (any) It should be a value of the type expected by the command or a DeviceData object with this value inserted. It can be ommited if the command should not get any argument. Return: The result of the command. The type depends on the command. It may be None.
Throws: ConnectionFailed, CommunicationFailed, DeviceUnlocked, DevFailed from device
command_inout_asynch (self, cmd_name, cmd_param=None, forget=False) -> id
Execute asynchronously (polling model) a command on a device
Parameters:
cmd_name: (str) Command name. cmd_param: (any) It should be a value of the type expected by the command or a DeviceData object with this value inserted. It can be ommited if the command should not get any argument. If the command sould get no argument and you want to set the ‘forget’ param, use None for cmd_param. forget: (bool) If this flag is set to true, this means that the client does not care at all about the server answer and will even not try to get it. A false default value is provided. Please, note that device re-connection will not take place (in case it is needed) if the fire and forget mode is used. Therefore, an application using only fire and forget requests is not able to automatically re-connnect to device. Return: (int) This call returns an asynchronous call identifier which is needed to get the command result (see command_inout_reply)
Throws: ConnectionFailed, TypeError, anything thrown by command_query
command_inout_asynch( self, cmd_name, callback) -> None
command_inout_asynch( self, cmd_name, cmd_param, callback) -> None
Execute asynchronously (callback model) a command on a device.
Parameters:
cmd_name: (str) Command name. cmd_param: (any)It should be a value of the type expected by the command or a DeviceData object with this value inserted. It can be ommited if the command should not get any argument. callback: Any callable object (function, lambda...) or any oject with a method named “cmd_ended”. Return: None
Throws: ConnectionFailed, TypeError, anything thrown by command_query
command_inout_raw ( self, cmd_name, cmd_param=None) -> DeviceData
Execute a command on a device.
Parameters:
cmd_name: (str) Command name. cmd_param: (any) It should be a value of the type expected by the command or a DeviceData object with this value inserted. It can be ommited if the command should not get any argument. Return: A DeviceData object.
Throws: ConnectionFailed, CommunicationFailed, DeviceUnlocked, DevFailed from device
command_inout_reply (self, id) -> DeviceData
Check if the answer of an asynchronous command_inout is arrived (polling model). If the reply is arrived and if it is a valid reply, it is returned to the caller in a DeviceData object. If the reply is an exception, it is re-thrown by this call. An exception is also thrown in case of the reply is not yet arrived.
Parameters:
id: (int) Asynchronous call identifier. Return: Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device
command_inout_reply(self, id, timeout) -> DeviceData
Check if the answer of an asynchronous command_inout is arrived (polling model). id is the asynchronous call identifier. If the reply is arrived and if it is a valid reply, it is returned to the caller in a DeviceData object. If the reply is an exception, it is re-thrown by this call. If the reply is not yet arrived, the call will wait (blocking the process) for the time specified in timeout. If after timeout milliseconds, the reply is still not there, an exception is thrown. If timeout is set to 0, the call waits until the reply arrived.
Parameters:
id: (int) Asynchronous call identifier. timeout: (int) Return: Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device
command_inout_reply_raw (self, id, timeout) -> DeviceData
Check if the answer of an asynchronous command_inout is arrived (polling model). id is the asynchronous call identifier. If the reply is arrived and if it is a valid reply, it is returned to the caller in a DeviceData object. If the reply is an exception, it is re-thrown by this call. If the reply is not yet arrived, the call will wait (blocking the process) for the time specified in timeout. If after timeout milliseconds, the reply is still not there, an exception is thrown. If timeout is set to 0, the call waits until the reply arrived.
Parameters:
id: (int) Asynchronous call identifier. timeout: (int) Return: Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device
command_inout_reply_raw(self, id) -> DeviceData
Check if the answer of an asynchronous command_inout is arrived (polling model). If the reply is arrived and if it is a valid reply, it is returned to the caller in a DeviceData object. If the reply is an exception, it is re-thrown by this call. An exception is also thrown in case of the reply is not yet arrived.
Parameters:
id: (int) Asynchronous call identifier. Return: Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device
command_list_query (self) -> sequence<CommandInfo>
Query the device for information on all commands.
Parameters: None Return: (CommandInfoList) Sequence of CommandInfo objects
command_query (self, command) -> CommandInfo
Query the device for information about a single command.
Parameters:
command: (str) command name Return: (CommandInfo) object
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
Example: com_info = dev.command_query(""DevString"") print com_info.cmd_name print com_info.cmd_tag print com_info.in_type print com_info.out_type print com_info.in_type_desc print com_info.out_type_desc print com_info.disp_levelSee CommandInfo documentation string form more detail
connect (self, corba_name) -> None
Creates a connection to a TANGO device using it’s stringified CORBA reference i.e. IOR or corbaloc.
Parameters:
corba_name: (str) Name of the CORBA object Return: None
New in PyTango 7.0.0
delete_property(self, value)
Delete a the given of properties for this device. This method accepts the following types as value parameter: 1. string [in] - single property to be deleted 2. PyTango.DbDatum [in] - single property data to be deleted 3. PyTango.DbData [in] - several property data to be deleted 4. sequence<string> [in]- several property data to be deleted 5. sequence<DbDatum> [in] - several property data to be deleted 6. dict<str, obj> [in] - keys are property names to be deleted (values are ignored) 7. dict<str, DbDatum> [in] - several DbDatum.name are property names to be
deleted (keys are ignored)
Parameters:
value: can be one of the following: 1. string [in] - single property data to be deleted 2. PyTango.DbDatum [in] - single property data to be deleted 3. PyTango.DbData [in] - several property data to be deleted 4. sequence<string> [in]- several property data to be deleted 5. sequence<DbDatum> [in] - several property data to be deleted 6. dict<str, obj> [in] - keys are property names to be deleted (values are ignored) 7. dict<str, DbDatum> [in] - several DbDatum.name are property names
to be deleted (keys are ignored)
Return: None
Throws: ConnectionFailed, CommunicationFailed DevFailed from device (DB_SQLError)
description (self) -> str
Get device description.
Parameters: None Return: (str) describing the device
dev_name (self) -> str
Return the device name as it is stored locally
Parameters: None Return: (str)
event_queue_size (self, event_id) -> int
Returns the number of stored events in the event reception buffer. After every call to DeviceProxy.get_events(), the event queue size is 0. During event subscription the client must have chosen the ‘pull model’ for this event. event_id is the event identifier returned by the DeviceProxy.subscribe_event() method.
Parameters:
event_id: (int) event identifier Return: an integer with the queue size
Throws: New in PyTango 7.0.0
get_access_control (self) -> AccessControlType
Returns the current access control type
Parameters: None Return: (AccessControlType) The current access control type New in PyTango 7.0.0
get_asynch_replies (self, call_timeout) -> None
Try to obtain data returned by a command asynchronously requested. This method blocks for the specified timeout if the reply is not yet arrived. This method fires callback when the reply arrived. If the timeout is set to 0, the call waits undefinitely for the reply
Parameters:
call_timeout: (int) timeout in miliseconds Return: None
New in PyTango 7.0.0
get_asynch_replies (self) -> None
Try to obtain data returned by a command asynchronously requested. This method does not block if the reply has not yet arrived. It fires callback for already arrived replies.
Parameters: None Return: None New in PyTango 7.0.0
get_attribute_config ( self, name) -> AttributeInfoEx
Return the attribute configuration for a single attribute.
Parameters:
name: (str) attribute name Return: (AttributeInfoEx) Object containing the attribute information
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
Deprecated: use get_attribute_config_ex instead
get_attribute_config( self, names) -> AttributeInfoList
Return the attribute configuration for the list of specified attributes. To get all the attributes pass a sequence containing the constant PyTango.:class:constants.AllAttr
Parameters:
names: (sequence<str>) attribute names Return: (AttributeInfoList) Object containing the attributes information
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
Deprecated: use get_attribute_config_ex instead
get_attribute_config_ex ( self, name) -> AttributeInfoListEx :
Return the extended attribute configuration for a single attribute.
Parameters:
name: (str) attribute name Return: (AttributeInfoEx) Object containing the attribute information
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
get_attribute_config( self, names) -> AttributeInfoListEx :
Return the extended attribute configuration for the list of specified attributes. To get all the attributes pass a sequence containing the constant PyTango.:class:constants.AllAttr
Parameters:
names: (sequence<str>) attribute names Return: (AttributeInfoList) Object containing the attributes information
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
get_attribute_list (self) -> sequence<str>
Return the names of all attributes implemented for this device.
Parameters: None Return: sequence<str> Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
get_attribute_poll_period (self, attr_name) -> int
Return the attribute polling period.
Parameters:
attr_name: (str) attribute name Return: polling period in milliseconds
get_command_poll_period (self, cmd_name) -> int
Return the command polling period.
Parameters:
cmd_name: (str) command name Return: polling period in milliseconds
get_db_host (self) -> str
Returns a string with the database host.
Parameters: None Return: (str) New in PyTango 7.0.0
get_db_port (self) -> str
Returns a string with the database port.
Parameters: None Return: (str) New in PyTango 7.0.0
get_db_port_num (self) -> int
Returns an integer with the database port.
Parameters: None Return: (int) New in PyTango 7.0.0
get_device_db (self) -> Database
Returns the internal database reference
Parameters: None Return: (Database) object New in PyTango 7.0.0
get_events ( event_id, callback=None, extract_as=Numpy) -> None
The method extracts all waiting events from the event reception buffer.
If callback is not None, it is executed for every event. During event subscription the client must have chosen the pull model for this event. The callback will receive a parameter of type EventData, AttrConfEventData or DataReadyEventData depending on the type of the event (event_type parameter of subscribe_event).
If callback is None, the method extracts all waiting events from the event reception buffer. The returned event_list is a vector of EventData, AttrConfEventData or DataReadyEventData pointers, just the same data the callback would have received.
Parameters:
event_id: (int) is the event identifier returned by the DeviceProxy.subscribe_event() method. callback: (callable) Any callable object or any object with a “push_event” method. extract_as: (DeviceAttribute.ExtractAs) Return: None
Throws: See Also: subscribe_event
New in PyTango 7.0.0
get_from_env_var (self) -> bool
Returns True if determined by environment variable or False otherwise
Parameters: None Return: (bool) New in PyTango 7.0.0
get_idl_version (self) -> int
Get the version of the Tango Device interface implemented by the device
Parameters: None Return: (int)
get_last_event_date (self, event_id) -> TimeVal
Returns the arrival time of the last event stored in the event reception buffer. After every call to DeviceProxy:get_events(), the event reception buffer is empty. In this case an exception will be returned. During event subscription the client must have chosen the ‘pull model’ for this event. event_id is the event identifier returned by the DeviceProxy.subscribe_event() method.
Parameters:
event_id: (int) event identifier Return: (PyTango.TimeVal) representing the arrival time
Throws: New in PyTango 7.0.0
get_locker (self, lockinfo) -> bool
If the device is locked, this method returns True an set some locker process informations in the structure passed as argument. If the device is not locked, the method returns False.
Parameters:
lockinfo [out]: (PyTango.LockInfo) object that will be filled with lock informantion Return: (bool) True if the device is locked by us. Otherwise, False
New in PyTango 7.0.0
get_logging_level (self) -> int
- Returns the current device’s logging level, where:
- 0=OFF
- 1=FATAL
- 2=ERROR
- 3=WARNING
- 4=INFO
- 5=DEBUG
:Parameters:None :Return: (int) representing the current logging level
New in PyTango 7.0.0
get_logging_target (self) -> sequence<str>
Returns a sequence of string containing the current device’s logging targets. Each vector element has the following format: target_type::target_name. An empty sequence is returned is the device has no logging targets.
Parameters: None Return: a squence<str> with the logging targets New in PyTango 7.0.0
get_property (propname, value=None) -> PyTango.DbData
Get a (list) property(ies) for a device.
This method accepts the following types as propname parameter: 1. string [in] - single property data to be fetched 2. sequence<string> [in] - several property data to be fetched 3. PyTango.DbDatum [in] - single property data to be fetched 4. PyTango.DbData [in,out] - several property data to be fetched. 5. sequence<DbDatum> - several property data to be feteched
Note: for cases 3, 4 and 5 the ‘value’ parameter if given, is IGNORED.
If value is given it must be a PyTango.DbData that will be filled with the property values
Parameters:
propname: (any) property(ies) name(s) value: (DbData) (optional, default is None meaning that the method will create internally a PyTango.DbData and return it filled with the property values Return: (DbData) object containing the property(ies) value(s). If a PyTango.DbData is given as parameter, it returns the same object otherwise a new PyTango.DbData is returned
Throws: NonDbDevice, ConnectionFailed (with database), CommunicationFailed (with database), DevFailed from database device
get_property_list (self, filter, array=None) -> obj
Get the list of property names for the device. The parameter filter allows the user to filter the returned name list. The wildcard character is ‘*’. Only one wildcard character is allowed in the filter parameter.
Parameters:
filter[in]: (str) the filter wildcard array[out]: (sequence obj or None) (optional, default is None) an array to be filled with the property names. If None a new list will be created internally with the values. Return: the given array filled with the property names (or a new list if array is None)
Throws: NonDbDevice, WrongNameSyntax, ConnectionFailed (with database), CommunicationFailed (with database) DevFailed from database device
New in PyTango 7.0.0
get_source (self) -> DevSource
Get the data source(device, polling buffer, polling buffer then device) used by command_inout or read_attribute methods
Parameters: None
Return: Example: source = dev.get_source() if source == DevSource.CACHE_DEV : ...
get_timeout_millis (self) -> int
Get the client side timeout in milliseconds
Parameters: None Return: (int)
get_transparency_reconnection (self) -> bool
Returns the device transparency reconnection flag.
Parameters: None Return: (bool) True if transparency reconnection is set or False otherwise
import_info (self) -> DbDevImportInfo
Query the device for import info from the database.
Parameters: None
Return: Example: dev_import = dev.import_info() print dev_import.name print dev_import.exported print dev_ior.ior print dev_version.versionAll DbDevImportInfo fields are strings except for exported which is an integer”
info (self) -> DeviceInfo
A method which returns information on the device
Parameters: None
Return: (DeviceInfo) object
Example: dev_info = dev.info() print dev_info.dev_class print dev_info.server_id print dev_info.server_host print dev_info.server_version print dev_info.doc_url print dev_info.dev_type All DeviceInfo fields are strings except for the server_version which is an integer"
is_attribute_polled (self, attr_name) -> bool
True if the attribute is polled.
Parameters:
attr_name: (str) attribute name Return: boolean value
is_command_polled (self, cmd_name) -> bool
True if the command is polled.
Parameters:
cmd_name: (str) command name Return: boolean value
is_event_queue_empty (self, event_id) -> bool
Returns true when the event reception buffer is empty. During event subscription the client must have chosen the ‘pull model’ for this event. event_id is the event identifier returned by the DeviceProxy.subscribe_event() method.
Parameters:
event_id: (int) event identifier Return: (bool) True if queue is empty or False otherwise
Throws: New in PyTango 7.0.0
is_locked (self) -> bool
Returns True if the device is locked. Otherwise, returns False.
Parameters: None Return: (bool) True if the device is locked. Otherwise, False New in PyTango 7.0.0
is_locked_by_me (self) -> bool
Returns True if the device is locked by the caller. Otherwise, returns False (device not locked or locked by someone else)
Parameters: None Return: (bool) True if the device is locked by us. Otherwise, False New in PyTango 7.0.0
lock (self, (int)lock_validity) -> None
Lock a device. The lock_validity is the time (in seconds) the lock is kept valid after the previous lock call. A default value of 10 seconds is provided and should be fine in most cases. In case it is necessary to change the lock validity, it’s not possible to ask for a validity less than a minimum value set to 2 seconds. The library provided an automatic system to periodically re lock the device until an unlock call. No code is needed to start/stop this automatic re-locking system. The locking system is re-entrant. It is then allowed to call this method on a device already locked by the same process. The locking system has the following features:
- It is impossible to lock the database device or any device server process admin device
- Destroying a locked DeviceProxy unlocks the device
- Restarting a locked device keeps the lock
- It is impossible to restart a device locked by someone else
- Restarting a server breaks the lock
A locked device is protected against the following calls when executed by another client:
- command_inout call except for device state and status requested via command and for the set of commands defined as allowed following the definition of allowed command in the Tango control access schema.
- write_attribute call
- write_read_attribute call
- set_attribute_config call
Parameters:
lock_validity: (int) lock validity time in seconds (optional, default value is PyTango.constants.DEFAULT_LOCK_VALIDITY) Return: None
New in PyTango 7.0.0
locking_status (self) -> str
This method returns a plain string describing the device locking status. This string can be:
- ‘Device <device name> is not locked’ in case the device is not locked
- ‘Device <device name> is locked by CPP or Python client with PID <pid> from host <host name>’ in case the device is locked by a CPP client
- ‘Device <device name> is locked by JAVA client class <main class> from host <host name>’ in case the device is locked by a JAVA client
Parameters: None Return: a string representing the current locking status New in PyTango 7.0.0”
name (self) -> str
Return the device name from the device itself.
pending_asynch_call (self) -> int
Return number of device asynchronous pending requests”New in PyTango 7.0.0
ping (self) -> int
A method which sends a ping to the device
Parameters: None Return: (int) time elapsed in milliseconds Throw : exception if device is not alive
poll_attribute (self, attr_name, period) -> None
Add an attribute to the list of polled attributes.
Parameters:
attr_name: (str) attribute name period: (int) polling period in milliseconds Return: None
poll_command (self, cmd_name, period) -> None
Add a command to the list of polled commands.
Parameters:
cmd_name: (str) command name period: (int) polling period in milliseconds Return: None
polling_status (self) -> sequence<str>
Return the device polling status.
Parameters: None
Return: (sequence<str>) One string for each polled command/attribute. Each string is multi-line string with
- attribute/command name
- attribute/command polling period in milliseconds
- attribute/command polling ring buffer
- time needed for last attribute/command execution in milliseconds
- time since data in the ring buffer has not been updated
- delta time between the last records in the ring buffer
- exception parameters in case of the last execution failed
put_property (self, value) -> None
Insert or update a list of properties for this device. This method accepts the following types as value parameter: 1. PyTango.DbDatum - single property data to be inserted 2. PyTango.DbData - several property data to be inserted 3. sequence<DbDatum> - several property data to be inserted 4. dict<str, DbDatum> - keys are property names and value has data to be inserted 5. dict<str, seq<str>> - keys are property names and value has data to be inserted 6. dict<str, obj> - keys are property names and str(obj) is property value
Parameters:
value: can be one of the following: 1. PyTango.DbDatum - single property data to be inserted 2. PyTango.DbData - several property data to be inserted 3. sequence<DbDatum> - several property data to be inserted 4. dict<str, DbDatum> - keys are property names and value has data to be inserted 5. dict<str, seq<str>> - keys are property names and value has data to be inserted 6. dict<str, obj> - keys are property names and str(obj) is property value Return: None
Throws: ConnectionFailed, CommunicationFailed DevFailed from device (DB_SQLError)
read_attribute (self, attr_name, extract_as=ExtractAs.Numpy) -> DeviceAttribute
Read a single attribute.
Parameters:
attr_name: (str) The name of the attribute to read. extract_as: (DeviceAttribute.ExtractAs) Defaults to numpy. Return: Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
read_attribute_asynch ( self, attr_name) -> int
read_attribute_asynch ( self, attr_name, callback) -> None
Shortcut to self.read_attributes_asynch([attr_name], cb)New in PyTango 7.0.0
read_attribute_reply ( self, id, extract_as) -> int
read_attribute_reply ( self, id, timeout, extract_as) -> None
Shortcut to self.read_attributes_reply()[0]New in PyTango 7.0.0
read_attributes (self, attr_names, extract_as=ExtractAs.Numpy) -> sequence<DeviceAttribute>
Read the list of specified attributes.
Parameters:
attr_names: (sequence<str>) A list of attributes to read. extract_as: (DeviceAttribute.ExtractAs) Defaults to numpy. Return: (sequence<DeviceAttribute>)
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
read_attributes_asynch ( self, attr_names) -> int
Read asynchronously (polling model) the list of specified attributes.
Parameters:
attr_names: (sequence<str>) A list of attributes to read. It should be a StdStringVector or a sequence of str. Return: an asynchronous call identifier which is needed to get attributes value.
Throws: New in PyTango 7.0.0
read_attributes_asynch ( self, attr_names, callback, extract_as=Numpy) -> None
Read asynchronously (callback model) an attribute list.
Parameters:
attr_names: (sequence<str>) A list of attributes to read. See read_attributes. callback: (callable) This callback object should be an instance of a user class with an attr_read() method. It can also be any callable object. extract_as: (DeviceAttribute.ExtractAs) Defaults to numpy. Return: None
Throws: New in PyTango 7.0.0
read_attributes_reply (self, id, extract_as=ExtractAs.Numpy) -> DeviceAttribute
Check if the answer of an asynchronous read_attribute is arrived (polling model).
Parameters:
id: (int) is the asynchronous call identifier. extract_as: (DeviceAttribute.ExtractAs) Return: If the reply is arrived and if it is a valid reply, it is returned to the caller in a list of DeviceAttribute. If the reply is an exception, it is re-thrown by this call. An exception is also thrown in case of the reply is not yet arrived.
Throws: AsynCall, AsynReplyNotArrived, ConnectionFailed, CommunicationFailed, DevFailed from device
New in PyTango 7.0.0
read_attributes_reply (self, id, timeout, extract_as=ExtractAs.Numpy) -> DeviceAttribute
Check if the answer of an asynchronous read_attributes is arrived (polling model).
Parameters:
id: (int) is the asynchronous call identifier. timeout: (int) extract_as: (DeviceAttribute.ExtractAs) Return: If the reply is arrived and if it is a valid reply, it is returned to the caller in a list of DeviceAttribute. If the reply is an exception, it is re-thrown by this call. If the reply is not yet arrived, the call will wait (blocking the process) for the time specified in timeout. If after timeout milliseconds, the reply is still not there, an exception is thrown. If timeout is set to 0, the call waits until the reply arrived.
Throws: AsynCall, AsynReplyNotArrived, ConnectionFailed, CommunicationFailed, DevFailed from device
New in PyTango 7.0.0
reconnect (self, db_used) -> None
Reconnecto to a CORBA object.
Parameters:
db_used: (bool) Use thatabase Return: None
New in PyTango 7.0.0
remove_logging_target (self, target_type_target_name) -> None
Removes a logging target from the device’s target list.
The target_type_target_name input parameter must follow the format: target_type::target_name. Supported target types are: console, file and device. For a device target, the target_name part of the target_type_target_name parameter must contain the name of a log consumer device (as defined in ). For a file target, target_name is the full path to the file to remove. If omitted, the default log file is removed. Finally, the target_name part of the target_type_target_name input parameter is ignored in case of a console target and can be omitted. If target_name is set to ‘*’, all targets of the specified target_type are removed.
Parameters:
target_type_target_name: (str) logging target Return: None
New in PyTango 7.0.0
set_access_control (self, acc) -> None
Sets the current access control type
Parameters:
acc: (AccessControlType) the type of access control to set Return: None
New in PyTango 7.0.0
set_attribute_config ( self, attr_info) -> None
Change the attribute configuration for the specified attribute
Parameters:
attr_info: (AttributeInfo) attribute information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
set_attribute_config( self, attr_info_ex) -> None
Change the extended attribute configuration for the specified attribute
Parameters:
attr_info_ex: (AttributeInfoEx) extended attribute information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
set_attribute_config( self, attr_info) -> None
Change the attributes configuration for the specified attributes
Parameters:
attr_info: (sequence<AttributeInfo>) attributes information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
set_attribute_config( self, attr_info_ex) -> None
Change the extended attributes configuration for the specified attributes
Parameters:
attr_info_ex: (sequence<AttributeInfoListEx>) extended attributes information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
set_logging_level (self, (int)level) -> None
- Changes the device’s logging level, where:
- 0=OFF
- 1=FATAL
- 2=ERROR
- 3=WARNING
- 4=INFO
- 5=DEBUG
Parameters:
level: (int) logging level Return: None
New in PyTango 7.0.0
set_source (self, source) -> None
Set the data source(device, polling buffer, polling buffer then device) for command_inout and read_attribute methods.
Parameters:
source: (DevSource) constant. Return: None
Example: dev.set_source(DevSource.CACHE_DEV)
set_timeout_millis (self, timeout) -> None
Set client side timeout for device in milliseconds. Any method which takes longer than this time to execute will throw an exception
Parameters:
timeout: integer value of timeout in milliseconds Return: None
Example: dev.set_timeout_millis(1000)
set_transparency_reconnection (self, yesno) -> None
Set the device transparency reconnection flag
Parameters: ” - val : (bool) True to set transparency reconnection ” or False otherwise Return: None
state (self) -> DevState
A method which returns the state of the device.
Parameters: None
Return: (DevState) constant
Example: dev_st = dev.state() if dev_st == DevState.ON : ...
status (self) -> str
A method which returns the status of the device as a string.
Parameters: None Return: (str) describing the device status
stop_poll_attribute (self, attr_name) -> None
Remove an attribute from the list of polled attributes.
Parameters:
attr_name: (str) attribute name Return: None
stop_poll_command (self, cmd_name) -> None
Remove a command from the list of polled commands.
Parameters:
cmd_name: (str) command name Return: None
subscribe_event (self, attr_name, event, callback, filters=[], stateless=False, extract_as=Numpy) -> int
The client call to subscribe for event reception in the push model. The client implements a callback method which is triggered when the event is received. Filtering is done based on the reason specified and the event type. For example when reading the state and the reason specified is “change” the event will be fired only when the state changes. Events consist of an attribute name and the event reason. A standard set of reasons are implemented by the system, additional device specific reasons can be implemented by device servers programmers.
Parameters:
attr_name: (str) The device attribute name which will be sent as an event e.g. “current”. event_type: (EventType) Is the event reason and must be on the enumerated values: * EventType.CHANGE_EVENT * EventType.PERIODIC_EVENT * EventType.ARCHIVE_EVENT * EventType.ATTR_CONF_EVENT * EventType.DATA_READY_EVENT * EventType.USER_EVENT callback: (callable) Is any callable object or an object with a callable “push_event” method. filters: (sequence<str>) A variable list of name,value pairs which define additional filters for events. stateless: (bool) When the this flag is set to false, an exception will be thrown when the event subscription encounters a problem. With the stateless flag set to true, the event subscription will always succeed, even if the corresponding device server is not running. The keep alive thread will try every 10 seconds to subscribe for the specified event. At every subscription retry, a callback is executed which contains the corresponding exception extract_as: (DeviceAttribute.ExtractAs) Return: An event id which has to be specified when unsubscribing from this event.
Throws:
subscribe_event(self, attr_name, event, queuesize, filters=[], stateless=False ) -> int
The client call to subscribe for event reception in the pull model. Instead of a callback method the client has to specify the size of the event reception buffer. The event reception buffer is implemented as a round robin buffer. This way the client can set-up different ways to receive events:
- Event reception buffer size = 1 : The client is interested only in the value of the last event received. All other events that have been received since the last reading are discarded.
- Event reception buffer size > 1 : The client has chosen to keep an event history of a given size. When more events arrive since the last reading, older events will be discarded.
- Event reception buffer size = ALL_EVENTS : The client buffers all received events. The buffer size is unlimited and only restricted by the available memory for the client.
All other parameters are similar to the descriptions given in the other subscribe_event() version.
unlock (self, (bool)force) -> None
Unlock a device. If used, the method argument provides a back door on the locking system. If this argument is set to true, the device will be unlocked even if the caller is not the locker. This feature is provided for administration purpopse and should be used very carefully. If this feature is used, the locker will receive a DeviceUnlocked during the next call which is normally protected by the locking Tango system.
Parameters:
force: (bool) force unlocking even if we are not the locker (optional, default value is False) Return: None
New in PyTango 7.0.0
unsubscribe_event (self, event_id) -> None
Unsubscribes a client from receiving the event specified by event_id.
Parameters:
event_id: (int) is the event identifier returned by the DeviceProxy::subscribe_event(). Unlike in TangoC++ we chech that the event_id has been subscribed in this DeviceProxy. Return: None
Throws:
write_attribute (self, attr_name, value) -> None
write_attribute (self, attr_info, value) -> None
Write a single attribute.
Parameters:
attr_name: (str) The name of the attribute to write. attr_info: (AttributeInfo) value: The value. For non SCALAR attributes it may be any sequence of sequences. Throws: ConnectionFailed, CommunicationFailed, DeviceUnlocked, DevFailed from device
write_attributes_asynch( self, values) -> int write_attributes_asynch( self, values, callback) -> None
Shortcut to self.write_attributes_asynch([attr_name, value], cb)New in PyTango 7.0.0
write_attributes_reply(self, id) -> None
Check if the answer of an asynchronous write_attributes is arrived (polling model). If the reply is arrived and if it is a valid reply, the call returned. If the reply is an exception, it is re-thrown by this call. An exception is also thrown in case of the reply is not yet arrived.
Parameters:
id: (int) the asynchronous call identifier. Return: None
Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device.
New in PyTango 7.0.0
write_attributes_reply(self, id, timeout) -> None
Check if the answer of an asynchronous write_attributes is arrived (polling model). id is the asynchronous call identifier. If the reply is arrived and if it is a valid reply, the call returned. If the reply is an exception, it is re-thrown by this call. If the reply is not yet arrived, the call will wait (blocking the process) for the time specified in timeout. If after timeout milliseconds, the reply is still not there, an exception is thrown. If timeout is set to 0, the call waits until the reply arrived.
Parameters:
id: (int) the asynchronous call identifier. timeout: (int) Return: None
Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device.
New in PyTango 7.0.0
write_attributes (self, name_val) -> None
Write the specified attributes.
Parameters:
name_val: A list of pairs (attr_name, value). See write_attribute Throws: ConnectionFailed, CommunicationFailed, DeviceUnlocked, DevFailed or NamedDevFailedList from device
write_attributes_asynch ( self, values) -> int
Write asynchronously (polling model) the specified attributes.
Parameters:
values: (any) See write_attributes. Return: An asynchronous call identifier which is needed to get the server reply
Throws: New in PyTango 7.0.0
write_attributes_asynch ( self, values, callback) -> None
Write asynchronously (callback model) a single attribute.
Parameters:
values: (any) See write_attributes. callback: (callable) This callback object should be an instance of a user class with an attr_written() method . It can also be any callable object. Return: None
Throws: New in PyTango 7.0.0
write_attributes_reply (self, id) -> None
Check if the answer of an asynchronous write_attributes is arrived (polling model). If the reply is arrived and if it is a valid reply, the call returned. If the reply is an exception, it is re-thrown by this call. An exception is also thrown in case of the reply is not yet arrived.
Parameters:
id: (int) the asynchronous call identifier. Return: None
Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device.
New in PyTango 7.0.0
write_attributes_reply (self, id, timeout) -> None
Check if the answer of an asynchronous write_attributes is arrived (polling model). id is the asynchronous call identifier. If the reply is arrived and if it is a valid reply, the call returned. If the reply is an exception, it is re-thrown by this call. If the reply is not yet arrived, the call will wait (blocking the process) for the time specified in timeout. If after timeout milliseconds, the reply is still not there, an exception is thrown. If timeout is set to 0, the call waits until the reply arrived.
Parameters:
id: (int) the asynchronous call identifier. timeout: (int) Return: None
Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device.
New in PyTango 7.0.0
write_read_attribute (self, attr_name, value, extract_as=ExtractAs.Numpy) -> DeviceAttribute
Write then read a single attribute in a single network call. By default (serialisation by device), the execution of this call in the server can’t be interrupted by other clients.
Parameters: see write_attribute(attr_name, value) Return: A PyTango.DeviceAttribute object. Throws: ConnectionFailed, CommunicationFailed, DeviceUnlocked, DevFailed from device, WrongData New in PyTango 7.0.0