AttributeProxy is the high level Tango object which provides the client with an easy-to-use interface to TANGO attributes.
To create an AttributeProxy, a complete attribute name must be set in the object constructor.
Note: PyTango implementation of AttributeProxy is in part a python reimplementation of the AttributeProxy found on the C++ API.
delete_property (self, value) -> None
Delete a the given of properties for this attribute. This method accepts the following types as value parameter: 1. string [in] - single property to be deleted 2. PyTango.DbDatum [in] - single property data to be deleted 3. PyTango.DbData [in] - several property data to be deleted 4. sequence<string> [in]- several property data to be deleted 5. sequence<DbDatum> [in] - several property data to be deleted 6. dict<str, obj> [in] - keys are property names to be deleted (values are ignored) 7. dict<str, DbDatum> [in] - several DbDatum.name are property names to be
deleted (keys are ignored)
Parameters:
value: can be one of the following: 1. string [in] - single property data to be deleted 2. PyTango.DbDatum [in] - single property data to be deleted 3. PyTango.DbData [in] - several property data to be deleted 4. sequence<string> [in]- several property data to be deleted 5. sequence<DbDatum> [in] - several property data to be deleted 6. dict<str, obj> [in] - keys are property names to be deleted (values are ignored) 7. dict<str, DbDatum> [in] - several DbDatum.name are property names
to be deleted (keys are ignored)
Return: None
Throws: ConnectionFailed, CommunicationFailed DevFailed from device (DB_SQLError)
For convenience, here is the documentation of DeviceProxy.event_queue_size(...):
event_queue_size(self, event_id) -> int
Returns the number of stored events in the event reception buffer. After every call to DeviceProxy.get_events(), the event queue size is 0. During event subscription the client must have chosen the ‘pull model’ for this event. event_id is the event identifier returned by the DeviceProxy.subscribe_event() method.
Parameters:
event_id: (int) event identifier Return: an integer with the queue size
Throws: New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.get_attribute_config(...):
get_attribute_config( self, name) -> AttributeInfoEx
Return the attribute configuration for a single attribute.
Parameters:
name: (str) attribute name Return: (AttributeInfoEx) Object containing the attribute information
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
Deprecated: use get_attribute_config_ex instead
get_attribute_config( self, names) -> AttributeInfoList
Return the attribute configuration for the list of specified attributes. To get all the attributes pass a sequence containing the constant PyTango.:class:constants.AllAttr
Parameters:
names: (sequence<str>) attribute names Return: (AttributeInfoList) Object containing the attributes information
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
Deprecated: use get_attribute_config_ex instead
get_device_proxy (self) -> DeviceProxy
A method which returns the device associated to the attribute
Parameters: None Return: (DeviceProxy)
For convenience, here is the documentation of DeviceProxy.get_events(...):
get_events( event_id, callback=None, extract_as=Numpy) -> None
The method extracts all waiting events from the event reception buffer.
If callback is not None, it is executed for every event. During event subscription the client must have chosen the pull model for this event. The callback will receive a parameter of type EventData, AttrConfEventData or DataReadyEventData depending on the type of the event (event_type parameter of subscribe_event).
If callback is None, the method extracts all waiting events from the event reception buffer. The returned event_list is a vector of EventData, AttrConfEventData or DataReadyEventData pointers, just the same data the callback would have received.
Parameters:
event_id: (int) is the event identifier returned by the DeviceProxy.subscribe_event() method. callback: (callable) Any callable object or any object with a “push_event” method. extract_as: (DeviceAttribute.ExtractAs) Return: None
Throws: See Also: subscribe_event
New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.get_last_event_date(...):
get_last_event_date(self, event_id) -> TimeVal
Returns the arrival time of the last event stored in the event reception buffer. After every call to DeviceProxy:get_events(), the event reception buffer is empty. In this case an exception will be returned. During event subscription the client must have chosen the ‘pull model’ for this event. event_id is the event identifier returned by the DeviceProxy.subscribe_event() method.
Parameters:
event_id: (int) event identifier Return: (PyTango.TimeVal) representing the arrival time
Throws: New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.get_attribute_poll_period(...):
get_attribute_poll_period(self, attr_name) -> int
Return the attribute polling period.
Parameters:
attr_name: (str) attribute name Return: polling period in milliseconds
get_property (self, propname, value) -> DbData
Get a (list) property(ies) for an attribute.
This method accepts the following types as propname parameter: 1. string [in] - single property data to be fetched 2. sequence<string> [in] - several property data to be fetched 3. PyTango.DbDatum [in] - single property data to be fetched 4. PyTango.DbData [in,out] - several property data to be fetched. 5. sequence<DbDatum> - several property data to be feteched
Note: for cases 3, 4 and 5 the ‘value’ parameter if given, is IGNORED.
If value is given it must be a PyTango.DbData that will be filled with the property values
Parameters:
propname: (str) property(ies) name(s) value: (PyTango.DbData) (optional, default is None meaning that the method will create internally a PyTango.DbData and return it filled with the property values Return: (DbData) containing the property(ies) value(s). If a PyTango.DbData is given as parameter, it returns the same object otherwise a new PyTango.DbData is returned
Throws: NonDbDevice, ConnectionFailed (with database), CommunicationFailed (with database), DevFailed from database device
For convenience, here is the documentation of DeviceProxy.get_transparency_reconnection(...):
get_transparency_reconnection(self) -> bool
Returns the device transparency reconnection flag.
Parameters: None Return: (bool) True if transparency reconnection is set or False otherwise
For convenience, here is the documentation of DeviceProxy.attribute_history(...):
attribute_history(self, attr_name, depth, extract_as=ExtractAs.Numpy) -> sequence<DeviceAttributeHistory>
Retrieve attribute history from the attribute polling buffer. See chapter on Advanced Feature for all details regarding polling
Parameters:
attr_name: (str) Attribute name. depth: (int) The wanted history depth. extract_as: (DeviceAttribute.ExtractAs) Return: This method returns a vector of DeviceAttributeHistory types.
Throws: NonSupportedFeature, ConnectionFailed, CommunicationFailed, DevFailed from device
For convenience, here is the documentation of DeviceProxy.is_event_queue_empty(...):
is_event_queue_empty(self, event_id) -> bool
Returns true when the event reception buffer is empty. During event subscription the client must have chosen the ‘pull model’ for this event. event_id is the event identifier returned by the DeviceProxy.subscribe_event() method.
Parameters:
event_id: (int) event identifier Return: (bool) True if queue is empty or False otherwise
Throws: New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.is_attribute_polled(...):
is_attribute_polled(self, attr_name) -> bool
True if the attribute is polled.
Parameters:
attr_name: (str) attribute name Return: boolean value
name (self) -> str
Returns the attribute name
Parameters: None Return: (str) with the attribute name
For convenience, here is the documentation of DeviceProxy.ping(...):
ping(self) -> int
A method which sends a ping to the device
Parameters: None Return: (int) time elapsed in milliseconds Throw : exception if device is not alive
For convenience, here is the documentation of DeviceProxy.poll_attribute(...):
poll_attribute(self, attr_name, period) -> None
Add an attribute to the list of polled attributes.
Parameters:
attr_name: (str) attribute name period: (int) polling period in milliseconds Return: None
put_property (self, value) -> None
Insert or update a list of properties for this attribute. This method accepts the following types as value parameter: 1. PyTango.DbDatum - single property data to be inserted 2. PyTango.DbData - several property data to be inserted 3. sequence<DbDatum> - several property data to be inserted 4. dict<str, DbDatum> - keys are property names and value has data to be inserted 5. dict<str, seq<str>> - keys are property names and value has data to be inserted 6. dict<str, obj> - keys are property names and str(obj) is property value
Parameters:
value: can be one of the following: 1. PyTango.DbDatum - single property data to be inserted 2. PyTango.DbData - several property data to be inserted 3. sequence<DbDatum> - several property data to be inserted 4. dict<str, DbDatum> - keys are property names and value has data to be inserted 5. dict<str, seq<str>> - keys are property names and value has data to be inserted 6. dict<str, obj> - keys are property names and str(obj) is property value Return: None
Throws: ConnectionFailed, CommunicationFailed DevFailed from device (DB_SQLError)
For convenience, here is the documentation of DeviceProxy.read_attribute(...):
read_attribute(self, attr_name, extract_as=ExtractAs.Numpy) -> DeviceAttribute
Read a single attribute.
Parameters:
attr_name: (str) The name of the attribute to read. extract_as: (DeviceAttribute.ExtractAs) Defaults to numpy. Return: Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
For convenience, here is the documentation of DeviceProxy.read_attribute_asynch(...):
read_attribute_asynch( self, attr_name) -> int read_attribute_asynch( self, attr_name, callback) -> None
Shortcut to self.read_attributes_asynch([attr_name], cb)New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.read_attribute_reply(...):
read_attribute_reply( self, id, extract_as) -> int read_attribute_reply( self, id, timeout, extract_as) -> None
Shortcut to self.read_attributes_reply()[0]New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.set_attribute_config(...):
set_attribute_config( self, attr_info) -> None
Change the attribute configuration for the specified attribute
Parameters:
attr_info: (AttributeInfo) attribute information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
set_attribute_config( self, attr_info_ex) -> None
Change the extended attribute configuration for the specified attribute
Parameters:
attr_info_ex: (AttributeInfoEx) extended attribute information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
set_attribute_config( self, attr_info) -> None
Change the attributes configuration for the specified attributes
Parameters:
attr_info: (sequence<AttributeInfo>) attributes information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
set_attribute_config( self, attr_info_ex) -> None
Change the extended attributes configuration for the specified attributes
Parameters:
attr_info_ex: (sequence<AttributeInfoListEx>) extended attributes information Return: None
Throws: ConnectionFailed, CommunicationFailed, DevFailed from device
For convenience, here is the documentation of DeviceProxy.set_transparency_reconnection(...):
set_transparency_reconnection(self, yesno) -> None
Set the device transparency reconnection flag
Parameters: ” - val : (bool) True to set transparency reconnection ” or False otherwise Return: None
For convenience, here is the documentation of DeviceProxy.state(...):
state(self) -> DevState
A method which returns the state of the device.
Parameters: None
Return: (DevState) constant
Example: dev_st = dev.state() if dev_st == DevState.ON : ...
For convenience, here is the documentation of DeviceProxy.status(...):
status(self) -> str
A method which returns the status of the device as a string.
Parameters: None Return: (str) describing the device status
For convenience, here is the documentation of DeviceProxy.stop_poll_attribute(...):
stop_poll_attribute(self, attr_name) -> None
Remove an attribute from the list of polled attributes.
Parameters:
attr_name: (str) attribute name Return: None
For convenience, here is the documentation of DeviceProxy.subscribe_event(...):
subscribe_event(self, attr_name, event, callback, filters=[], stateless=False, extract_as=Numpy) -> int
The client call to subscribe for event reception in the push model. The client implements a callback method which is triggered when the event is received. Filtering is done based on the reason specified and the event type. For example when reading the state and the reason specified is “change” the event will be fired only when the state changes. Events consist of an attribute name and the event reason. A standard set of reasons are implemented by the system, additional device specific reasons can be implemented by device servers programmers.
Parameters:
attr_name: (str) The device attribute name which will be sent as an event e.g. “current”. event_type: (EventType) Is the event reason and must be on the enumerated values: * EventType.CHANGE_EVENT * EventType.PERIODIC_EVENT * EventType.ARCHIVE_EVENT * EventType.ATTR_CONF_EVENT * EventType.DATA_READY_EVENT * EventType.USER_EVENT callback: (callable) Is any callable object or an object with a callable “push_event” method. filters: (sequence<str>) A variable list of name,value pairs which define additional filters for events. stateless: (bool) When the this flag is set to false, an exception will be thrown when the event subscription encounters a problem. With the stateless flag set to true, the event subscription will always succeed, even if the corresponding device server is not running. The keep alive thread will try every 10 seconds to subscribe for the specified event. At every subscription retry, a callback is executed which contains the corresponding exception extract_as: (DeviceAttribute.ExtractAs) Return: An event id which has to be specified when unsubscribing from this event.
Throws: subscribe_event(self, attr_name, event, queuesize, filters=[], stateless=False ) -> int
The client call to subscribe for event reception in the pull model. Instead of a callback method the client has to specify the size of the event reception buffer. The event reception buffer is implemented as a round robin buffer. This way the client can set-up different ways to receive events:
- Event reception buffer size = 1 : The client is interested only in the value of the last event received. All other events that have been received since the last reading are discarded.
- Event reception buffer size > 1 : The client has chosen to keep an event history of a given size. When more events arrive since the last reading, older events will be discarded.
- Event reception buffer size = ALL_EVENTS : The client buffers all received events. The buffer size is unlimited and only restricted by the available memory for the client.
All other parameters are similar to the descriptions given in the other subscribe_event() version.
For convenience, here is the documentation of DeviceProxy.unsubscribe_event(...):
unsubscribe_event(self, event_id) -> None
Unsubscribes a client from receiving the event specified by event_id.
Parameters:
event_id: (int) is the event identifier returned by the DeviceProxy::subscribe_event(). Unlike in TangoC++ we chech that the event_id has been subscribed in this DeviceProxy. Return: None
Throws:
For convenience, here is the documentation of DeviceProxy.write_attribute(...):
write_attribute(self, attr_name, value) -> None write_attribute(self, attr_info, value) -> None
Write a single attribute.
Parameters:
attr_name: (str) The name of the attribute to write. attr_info: (AttributeInfo) value: The value. For non SCALAR attributes it may be any sequence of sequences. Throws: ConnectionFailed, CommunicationFailed, DeviceUnlocked, DevFailed from device
For convenience, here is the documentation of DeviceProxy.write_attribute_asynch(...):
write_attributes_asynch( self, values) -> int write_attributes_asynch( self, values, callback) -> None
Shortcut to self.write_attributes_asynch([attr_name, value], cb)New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.write_read_attribute(...):
write_read_attribute(self, attr_name, value, extract_as=ExtractAs.Numpy) -> DeviceAttribute
Write then read a single attribute in a single network call. By default (serialisation by device), the execution of this call in the server can’t be interrupted by other clients.
Parameters: see write_attribute(attr_name, value) Return: A PyTango.DeviceAttribute object. Throws: ConnectionFailed, CommunicationFailed, DeviceUnlocked, DevFailed from device, WrongData New in PyTango 7.0.0
For convenience, here is the documentation of DeviceProxy.write_attribute_reply(...):
write_attributes_reply(self, id) -> None
Check if the answer of an asynchronous write_attributes is arrived (polling model). If the reply is arrived and if it is a valid reply, the call returned. If the reply is an exception, it is re-thrown by this call. An exception is also thrown in case of the reply is not yet arrived.
Parameters:
id: (int) the asynchronous call identifier. Return: None
Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device.
New in PyTango 7.0.0
write_attributes_reply(self, id, timeout) -> None
Check if the answer of an asynchronous write_attributes is arrived (polling model). id is the asynchronous call identifier. If the reply is arrived and if it is a valid reply, the call returned. If the reply is an exception, it is re-thrown by this call. If the reply is not yet arrived, the call will wait (blocking the process) for the time specified in timeout. If after timeout milliseconds, the reply is still not there, an exception is thrown. If timeout is set to 0, the call waits until the reply arrived.
Parameters:
id: (int) the asynchronous call identifier. timeout: (int) Return: None
Throws: AsynCall, AsynReplyNotArrived, CommunicationFailed, DevFailed from device.
New in PyTango 7.0.0