Table Of Contents

Previous topic

DeviceClass

Next topic

Util

This Page

Attribute classes

Attr

class PyTango.Attr

This class represents a Tango writable attribute.

get_assoc()

get_assoc (self) -> str

Get the associated name.
Parameters:None
Return:(bool) the associated name
get_class_properties()

get_class_properties (self) -> sequence<AttrProperty>

Get the class level attribute properties
Parameters:None
Return:(sequence<AttrProperty>) the class attribute properties
get_disp_level()

get_disp_level (self) -> DispLevel

Get the attribute display level
Parameters:None
Return:(DispLevel) the attribute display level
get_format()

get_format (self) -> AttrDataFormat

Get the attribute format
Parameters:None
Return:(AttrDataFormat) the attribute format
get_memorized()

get_memorized (self) -> bool

Determine if the attribute is memorized or not.
Parameters:None
Return:(bool) True if the attribute is memorized
get_memorized_init()

get_memorized_init (self) -> bool

Determine if the attribute is written at startup from the memorized value if it is memorized
Parameters:None
Return:(bool) True if initialized with memorized value or not
get_name()

get_name (self) -> str

Get the attribute name.
Parameters:None
Return:(str) the attribute name
get_polling_period()

get_polling_period (self) -> int

Get the polling period (mS)
Parameters:None
Return:(int) the polling period (mS)
get_type()

get_type (self) -> int

Get the attribute data type
Parameters:None
Return:(int) the attribute data type
get_user_default_properties()

get_user_default_properties (self) -> sequence<AttrProperty>

Get the user default attribute properties
Parameters:None
Return:(sequence<AttrProperty>) the user default attribute properties
get_writable()

get_writable (self) -> AttrWriteType

Get the attribute write type
Parameters:None
Return:(AttrWriteType) the attribute write type
is_archive_event()

is_archive_event (self) -> bool

Check if the archive event is fired manually for this attribute.
Parameters:None
Return:(bool) true if a manual fire archive event is implemented.
is_assoc()

is_assoc (self) -> bool

Determine if it is assoc.
Parameters:None
Return:(bool) if it is assoc
is_change_event()

is_change_event (self) -> bool

Check if the change event is fired manually for this attribute.
Parameters:None
Return:(bool) true if a manual fire change event is implemented.
is_check_archive_criteria()

is_check_archive_criteria (self) -> bool

Check if the archive event criteria should be checked when firing the event manually.
Parameters:None
Return:(bool) true if a archive event criteria will be checked.
is_check_change_criteria()

is_check_change_criteria (self) -> bool

Check if the change event criteria should be checked when firing the event manually.
Parameters:None
Return:(bool) true if a change event criteria will be checked.
set_archive_event()

set_archive_event (self) -> None

Set a flag to indicate that the server fires archive events manually without the polling to be started for the attribute If the detect parameter is set to true, the criteria specified for the archive event are verified and the event is only pushed if they are fullfilled.

If detect is set to false the event is fired without checking!

Parameters:
implemented:(bool) True when the server fires change events manually.
detect:(bool) Triggers the verification of the archive event properties when set to true.
Return:

None

set_change_event()

set_change_event (self, implemented, detect) -> None

Set a flag to indicate that the server fires change events manually without the polling to be started for the attribute. If the detect parameter is set to true, the criteria specified for the change event are verified and the event is only pushed if they are fullfilled.

If detect is set to false the event is fired without checking!

Parameters:
implemented:(bool) True when the server fires change events manually.
detect:(bool) Triggers the verification of the change event properties when set to true.
Return:

None

set_class_properties()

set_class_properties (self, props) -> None

Set the class level attribute properties
Parameters:
props:(StdAttrPropertyVector) new class level attribute properties
Return:

None

set_default_properties()

set_default_properties (self) -> None

Set default attribute properties.
Parameters:
attr_prop:(UserDefaultAttrProp) the user default property class
Return:

None

set_disp_level()

set_disp_level (self, disp_lelel) -> None

Set the attribute display level.
Parameters:
disp_level:(DispLevel) the new display level
Return:

None

set_memorized()

set_memorized (self) -> None

Set the attribute as memorized in database (only for scalar and writable attribute) With no argument the setpoint will be written to the attribute during initialisation!
Parameters:None
Return:None
set_memorized_init()

set_memorized_init (self, write_on_init) -> None

Set the initialisation flag for memorized attributes true = the setpoint value will be written to the attribute on initialisation false = only the attribute setpoint is initialised. No action is taken on the attribute
Parameters:
write_on_init:(bool) if true the setpoint value will be written to the attribute on initialisation
Return:

None

set_polling_period()

set_polling_period (self, period) -> None

Set the attribute polling update period.
Parameters:
period:(int) the attribute polling period (in mS)
Return:

None

Attribute

class PyTango.Attribute

This class represents a Tango attribute.

check_alarm()

check_alarm (self) -> bool

Check if the attribute read value is below/above the alarm level.
Parameters:None
Return:(bool) true if the attribute is in alarm condition.
Throws:DevFailed If no alarm level is defined.
get_assoc_ind()

get_assoc_ind (self) -> int

Get index of the associated writable attribute.
Parameters:None
Return:(int) the index in the main attribute vector of the associated writable attribute
get_assoc_name()

get_assoc_name (self) -> str

Get name of the associated writable attribute.
Parameters:None
Return:(str) the associated writable attribute name
get_attr_serial_model()

get_attr_serial_model (self) -> AttrSerialModel

Get attribute serialization model.
Parameters:None
Return:(AttrSerialModel) The attribute serialization model

New in PyTango 7.1.0

get_data_format()

get_data_format (self) -> AttrDataFormat

Get attribute data format.
Parameters:None
Return:(AttrDataFormat) the attribute data format
get_data_size()

get_data_size (self) -> None

Get attribute data size.
Parameters:None
Return:(int) the attribute data size
get_data_type()

get_data_type (self) -> int

Get attribute data type.
Parameters:None
Return:(int) the attribute data type
get_date()

get_date (self) -> TimeVal

Get a COPY of the attribute date.
Parameters:None
Return:(TimeVal) the attribute date
get_label()

get_label (self, ) -> str

Get attribute label property.
Parameters:None
Return:(str) he attribute label
get_max_dim_x()

get_max_dim_x (self) -> int

Get attribute maximum data size in x dimension.
Parameters:None
Return:(int) the attribute maximum data size in x dimension. Set to 1 for scalar attribute
get_max_dim_y()

get_max_dim_y (self) -> int

Get attribute maximum data size in y dimension.
Parameters:None
Return:(int) the attribute maximum data size in y dimension. Set to 0 for scalar attribute
get_name()

get_name (self) -> str

Get attribute name.
Parameters:None
Return:(str) The attribute name
get_polling_period()

get_polling_period (self) -> int

Get attribute polling period.
Parameters:None
Return:(int) The attribute polling period in mS. Set to 0 when the attribute is not polled
get_quality()

get_quality (self) -> AttrQuality

Get a COPY of the attribute data quality.
Parameters:None
Return:(AttrQuality) the attribute data quality
get_writable()

get_writable (self) -> AttrWriteType

Get the attribute writable type (RO/WO/RW).
Parameters:None
Return:(AttrWriteType) The attribute write type.
get_x()

get_x (self) -> int

Get attribute data size in x dimension.
Parameters:None
Return:(int) the attribute data size in x dimension. Set to 1 for scalar attribute
get_y()

get_y (self) -> int

Get attribute data size in y dimension.
Parameters:None
Return:(int) the attribute data size in y dimension. Set to 1 for scalar attribute
is_archive_event()

is_archive_event (self) -> bool

Check if the archive event is fired manually (without polling) for this attribute.
Parameters:None
Return:(bool) True if a manual fire archive event is implemented.

New in PyTango 7.1.0

is_change_event()

is_change_event (self) -> bool

Check if the change event is fired manually (without polling) for this attribute.
Parameters:None
Return:(bool) True if a manual fire change event is implemented.

New in PyTango 7.1.0

is_check_archive_criteria()

is_check_archive_criteria (self) -> bool

Check if the archive event criteria should be checked when firing the event manually.
Parameters:None
Return:(bool) True if a archive event criteria will be checked.

New in PyTango 7.1.0

is_check_change_criteria()

is_check_change_criteria (self) -> bool

Check if the change event criteria should be checked when firing the event manually.
Parameters:None
Return:(bool) True if a change event criteria will be checked.

New in PyTango 7.1.0

is_max_alarm()

is_max_alarm (self) -> bool

Check if the attribute is in maximum alarm condition.
Parameters:None
Return:(bool) true if the attribute is in alarm condition (read value above the max. alarm).
is_max_warning()

is_max_warning (self) -> bool

Check if the attribute is in maximum warning condition.
Parameters:None
Return:(bool) true if the attribute is in warning condition (read value above the max. warning).
is_min_alarm()

is_min_alarm (self) -> bool

Check if the attribute is in minimum alarm condition.
Parameters:None
Return:(bool) true if the attribute is in alarm condition (read value below the min. alarm).
is_min_warning()

is_min_warning (self) -> bool

Check if the attribute is in minimum warning condition.
Parameters:None
Return:(bool) true if the attribute is in warning condition (read value below the min. warning).
is_polled()

is_polled (self) -> bool

Check if the attribute is polled.
Parameters:None
Return:(bool) true if the attribute is polled.
is_rds_alarm()

is_rds_alarmself) -> bool

Check if the attribute is in RDS alarm condition.
Parameters:None
Return:(bool) true if the attribute is in RDS condition (Read Different than Set).
is_write_associated()

is_write_associated (self) -> bool

Check if the attribute has an associated writable attribute.
Parameters:None
Return:(bool) True if there is an associated writable attribute
remove_configuration()

remove_configuration (self) -> None

Remove the attribute configuration from the database. This method can be used to clean-up all the configuration of an attribute to come back to its default values or the remove all configuration of a dynamic attribute before deleting it.

The method removes all configured attribute properties and removes the attribute from the list of polled attributes.

Parameters:None
Return:None

New in PyTango 7.1.0

set_archive_event()

set_archive_event (self, implemented, detect = True) -> None

Set a flag to indicate that the server fires archive events manually, without the polling to be started for the attribute If the detect parameter is set to true, the criteria specified for the archive event are verified and the event is only pushed if they are fullfilled.
Parameters:
implemented:(bool) True when the server fires archive events manually.
detect:(bool) (optional, default is True) Triggers the verification of the archive event properties when set to true.
Return:

None

New in PyTango 7.1.0

set_assoc_ind()

set_assoc_ind (self, index) -> None

Set index of the associated writable attribute.
Parameters:
index:(int) The new index in the main attribute vector of the associated writable attribute
Return:

None

set_attr_serial_model()

set_attr_serial_model (self, ser_model) -> void

Set attribute serialization model. This method allows the user to choose the attribute serialization model.
Parameters:
ser_model:(AttrSerialModel) The new serialisation model. The serialization model must be one of ATTR_BY_KERNEL, ATTR_BY_USER or ATTR_NO_SYNC
Return:

None

New in PyTango 7.1.0

set_change_event()

set_change_event (self, implemented, detect = True) -> None

Set a flag to indicate that the server fires change events manually, without the polling to be started for the attribute. If the detect parameter is set to true, the criteria specified for the change event are verified and the event is only pushed if they are fullfilled. If detect is set to false the event is fired without any value checking!
Parameters:
implemented:(bool) True when the server fires change events manually.
detect:(bool) (optional, default is True) Triggers the verification of the change event properties when set to true.
Return:

None

New in PyTango 7.1.0

set_date()

set_date (self, new_date) -> None

Set attribute date.
Parameters:
new_date:(TimeVal) the attribute date
Return:

None

set_quality()

set_quality (self, quality, send_event=False) -> None

Set attribute data quality.
Parameters:
quality:(AttrQuality) the new attribute data quality
send_event:(bool) true if a change event should be sent. Default is false.
Return:

None

set_value()

set_value (self, data, dim_x = 1, dim_y = 0) -> None

set_value(self, data) set_value (self, str_data, data) -> None

Set internal attribute value. This method stores the attribute read value inside the object. This method also stores the date when it is called and initializes the attribute quality factor.
Parameters:
data:the data to be set. Data must be compatible with the attribute type and format. In the DEPRECATED form for SPECTRUM and IMAGE attributes, data can be any type of FLAT sequence of elements compatible with the attribute type. In the new form (without dim_x or dim_y) data should be any sequence for SPECTRUM and a SEQUENCE of equal-lenght SEQUENCES for IMAGE attributes. The recommended sequence is a C continuous and aligned numpy array, as it can be optimized.
str_data:(str) special variation for DevEncoded data type. In this case ‘data’ must also be a str.
dim_x:(int) [DEPRECATED] the attribute x length. Default value is 1
dim_y:(int) [DEPRECATED] the attribute y length. Default value is 0
Return:

None

set_value_date_quality()

set_value_date_quality (self, data, time_stamp, quality, dim_x = 1, dim_y = 0) -> None

set_value_date_quality (self, data, time_stamp, quality) -> None

set_value_date_quality (self, str_data, data, time_stamp, quality) -> None

Set internal attribute value, date and quality factor. This method stores the attribute read value, the date and the attribute quality factor inside the object.
Parameters:
data:the data to be set. Data must be compatible with the attribute type and format. In the DEPRECATED form for SPECTRUM and IMAGE attributes, data can be any type of FLAT sequence of elements compatible with the attribute type. In the new form (without dim_x or dim_y) data should be any sequence for SPECTRUM and a SEQUENCE of equal-lenght SEQUENCES for IMAGE attributes. The recommended sequence is a C continuous and aligned numpy array, as it can be optimized.
str_data:(str) special variation for DevEncoded data type. In this case ‘data’ must also be a str.
dim_x:(int) [DEPRECATED] the attribute x length. Default value is 1
dim_y:(int) [DEPRECATED] the attribute y length. Default value is 0
time_stamp:(double) the time stamp
quality:(AttrQuality) the attribute quality factor
Return:

None

WAttribute

class PyTango.WAttribute

This class represents a Tango writable attribute.

get_max_value()

get_max_value (self) -> obj

Get attribute maximum value or throws an exception if the attribute does not have a maximum value.
Parameters:None
Return:(obj) an object with the python maximum value
get_min_value()

get_min_value (self) -> obj

Get attribute minimum value or throws an exception if the attribute does not have a minimum value.
Parameters:None
Return:(obj) an object with the python minimum value
get_write_value()

get_write_value (self, lst) -> None 

get_write_value (self, extract_as=ExtractAs.Numpy) -> obj

Retrieve the new value for writable attribute.
Parameters:
extract_as:(ExtractAs)
lst:[out] (list) a list object that will be filled with the attribute write value (DEPRECATED)
Return:

(obj) the attribute write value.

get_write_value_length()

get_write_value_length (self) -> int

Retrieve the new value length (data number) for writable attribute.
Parameters:None
Return:(int) the new value data length
is_max_value()

is_max_value (self, ) -> bool

Check if the attribute has a maximum value.
Parameters:None
Return:(bool) true if the attribute has a maximum value defined
is_min_value()

is_min_value (self) -> bool

Check if the attribute has a minimum value.
Parameters:None
Return:(bool) true if the attribute has a minimum value defined
set_max_value()

set_max_value (self, data) -> None

Set attribute maximum value.
Parameters:
data:the attribute maximum value. python data type must be compatible with the attribute data format and type.
Return:

None

set_min_value()

set_min_value (self, data) -> None

Set attribute minimum value.
Parameters:
data:the attribute minimum value. python data type must be compatible with the attribute data format and type.
Return:

None

MultiAttribute

class PyTango.MultiAttribute

There is one instance of this class for each device. This class is mainly an aggregate of Attribute or WAttribute objects. It eases management of multiple attributes

check_alarm()

check_alarm (self) -> bool

check_alarm (self, attr_name) -> bool

check_alarm (self, ind) -> bool

  • The 1st version of the method checks alarm on all attribute(s) with an alarm defined.
  • The 2nd version of the method checks alarm for one attribute with a given name.
  • The 3rd version of the method checks alarm for one attribute from its index in the main attributes vector.
Parameters:
attr_name:(str) attribute name
ind:(int) the attribute index
Return:

(bool) True if at least one attribute is in alarm condition

Throws:

DevFailed If at least one attribute does not have any alarm level defined

New in PyTango 7.0.0

get_attr_by_ind()

get_attr_by_ind (self, ind) -> Attribute

Get Attribute object from its index. This method returns an Attribute object from the index in the main attribute vector.
Parameters:
ind:(int) the attribute index
Return:

(Attribute) the attribute object

get_attr_by_name()

get_attr_by_name (self, attr_name) -> Attribute

Get Attribute object from its name. This method returns an Attribute object with a name passed as parameter. The equality on attribute name is case independant.
Parameters:
attr_name:(str) attribute name
Return:

(Attribute) the attribute object

Throws:

DevFailed If the attribute is not defined.

get_attr_ind_by_name()

get_attr_ind_by_name (self, attr_name) -> int

Get Attribute index into the main attribute vector from its name. This method returns the index in the Attribute vector (stored in the MultiAttribute object) of an attribute with a given name. The name equality is case independant.
Parameters:
attr_name:(str) attribute name
Return:

(int) the attribute index

Throws:

DevFailed If the attribute is not found in the vector.

New in PyTango 7.0.0

get_attr_nb()

get_attr_nb (self) -> int

Get attribute number.
Parameters:None
Return:(int) the number of attributes

New in PyTango 7.0.0

get_w_attr_by_ind()

get_w_attr_by_ind (self, ind) -> WAttribute

Get a writable attribute object from its index. This method returns an WAttribute object from the index in the main attribute vector.
Parameters:
ind:(int) the attribute index
Return:

(WAttribute) the attribute object

get_w_attr_by_name()

get_w_attr_by_name (self, attr_name) -> WAttribute

Get a writable attribute object from its name. This method returns an WAttribute object with a name passed as parameter. The equality on attribute name is case independant.
Parameters:
attr_name:(str) attribute name
Return:

(WAttribute) the attribute object

Throws:

DevFailed If the attribute is not defined.

read_alarm()

read_alarm (self, status) -> None

Add alarm message to device status. This method add alarm mesage to the string passed as parameter. A message is added for each attribute which is in alarm condition
Parameters:
status:(str) a string (should be the device status)
Return:

None

New in PyTango 7.0.0

UserDefaultAttrProp

class PyTango.UserDefaultAttrProp

User class to set attribute default properties. This class is used to set attribute default properties. Three levels of attributes properties setting are implemented within Tango. The highest property setting level is the database. Then the user default (set using this UserDefaultAttrProp class) and finally a Tango library default value

set_abs_change()

set_abs_change (self, def_abs_change) -> None

Set default change event abs_change property.
Parameters:
def_abs_change:(str) the user default change event abs_change property
Return:

None

set_archive_abs_change()

set_archive_abs_change (self, def_archive_abs_change) -> None

Set default archive event abs_change property.
Parameters:
def_archive_abs_change:
 (str) the user default archive event abs_change property
Return:

None

set_archive_period()

set_archive_period (self, def_archive_period) -> None

Set default archive event period property.
Parameters:
def_archive_period:
 (str) t
Return:

None

set_archive_rel_change()

set_archive_rel_change (self, def_archive_rel_change) -> None

Set default archive event rel_change property.
Parameters:
def_archive_rel_change:
 (str) the user default archive event rel_change property
Return:

None

set_delta_t()

set_delta_t (self, def_delta_t) -> None

Set default RDS alarm delta_t property.
Parameters:
def_delta_t:(str) the user default RDS alarm delta_t property
Return:

None

set_delta_val()

set_delta_val (self, def_delta_val) -> None

Set default RDS alarm delta_val property.
Parameters:
def_delta_val:(str) the user default RDS alarm delta_val property
Return:

None

set_description()

set_description (self, def_description) -> None

Set default description property.
Parameters:
def_description:
 (str) the user default description property
Return:

None

set_display_unit()

set_display_unit (self, def_display_unit) -> None

Set default display unit property.
Parameters:
def_display_unit:
 (str) the user default display unit property
Return:

None

set_format()

set_format (self, def_format) -> None

Set default format property.
Parameters:
def_format:(str) the user default format property
Return:

None

set_label()

set_label (self, def_label) -> None

Set default label property.
Parameters:
def_label:(str) the user default label property
Return:

None

set_max_alarm()

set_max_alarm (self, def_max_alarm) -> None

Set default max_alarm property.
Parameters:
def_max_alarm:(str) the user default max_alarm property
Return:

None

set_max_value()

set_max_value (self, def_max_value) -> None

Set default max_value property.
Parameters:
def_max_value:(str) the user default max_value property
Return:

None

set_max_warning()

set_max_warning (self, def_max_warning) -> None

Set default max_warning property.
Parameters:
def_max_warning:
 (str) the user default max_warning property
Return:

None

set_min_alarm()

set_min_alarm (self, def_min_alarm) -> None

Set default min_alarm property.
Parameters:
def_min_alarm:(str) the user default min_alarm property
Return:

None

set_min_value()

set_min_value (self, def_min_value) -> None

Set default min_value property.
Parameters:
def_min_value:(str) the user default min_value property
Return:

None

set_min_warning()

set_min_warning (self, def_min_warning) -> None

Set default min_warning property.
Parameters:
def_min_warning:
 (str) the user default min_warning property
Return:

None

set_period()

set_period (self, def_period) -> None

Set default periodic event period property.
Parameters:
def_period:(str) the user default periodic event period property
Return:

None

set_rel_change()

set_rel_change (self, def_rel_change) -> None

Set default change event rel_change property.
Parameters:
def_rel_change:(str) the user default change event rel_change property
Return:

None

set_standard_unit()

set_standard_unit (self, def_standard_unit) -> None

Set default standard unit property.
Parameters:
def_standard_unit:
 (str) the user default standard unit property
Return:

None

set_unit()

set_unit (self, def_unit) -> None

Set default unit property.
Parameters:
def_unit:(str) te user default unit property
Return:

None