Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Vacuum/VarianDualCtrl
Contact:



Class Description


This device server is intended to drive a Varian Dual ion pump controller.

Family: Vacuum

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Varian

Bus: Serial Line

Class interface


Attributes:

Commands:

Name Description
GetControllerInput: DevVoid
Output: DevString
type of contoller
get the type on Controller
SetStepModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the step mode.
SetStartModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the start mode.
SetProtectModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the protect mode.
SetMaxVoltageInput: DevVarShortArray
The channel number.
Output: DevVoid
Set the max voltage for the considered channel. - argin[0] = channel number - argin[1] = max voltage value
SetFixedModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the fixed mode.
RemoteInput: DevVoid
Output: DevVoid
Set the controller to the remote mode (operated using the serial line).
ReadVstep2Input: DevShort
The channel number
Output: DevLong
Read the vstep2 of the considered channel.
ReadVstep1Input: DevShort
The channel number
Output: DevLong
Read the vstep1 of the considered channel.
ReadVoltageInput: DevShort
The channel number
Output: DevFloat
The voltage value
Get the measure voltage value of the considered pump.
ReadVmaxInput: DevShort
The channel number
Output: DevLong
Read the Vmax of the considered channel.
ReadStateInput: DevShort
The channel number
Output: State
The state of the channel
Get the state of the considered channel.
ReadStartModeInput: DevShort
Channel number
Output: DevBoolean
Returns TRUE if the pump is in START mode, FALSE if the mode is PROTECT
ReadPressureInput: DevShort
The channel number.
Output: DevFloat
Read the pressure of the considered channel.
ReadIstep2Input: DevShort
The channel number
Output: DevFloat
Read the istep2 of the considered channel.
ReadIstep1Input: DevShort
The channel number
Output: DevFloat
Read the istep1 of the considered channel.
ReadIprotectInput: DevShort
The channel number
Output: DevLong
Read the iprotect of the considered channel.
ReadImaxInput: DevShort
The channel number
Output: DevLong
Read the imax of the considered channel.
ReadFixedModeInput: DevShort
Channel number
Output: DevBoolean
Returns TRUE if the pump is in FIXED mode, FALSE if the mode is STEP.
ReadCurrentInput: DevShort
The channel number
Output: DevFloat
The current value
Get the measure current value of the considered channel.
OnInput: DevShort
The channel number.
Output: DevVoid
Set to ON the considered channel.
OffInput: DevShort
The channel number.
Output: DevVoid
Set to OFF the considered channel.
LocalInput: DevVoid
Output: DevVoid
Set the controller to local mode (operated from front panel).
IsInitializedInput: DevShort
Channel number.
Output: DevBoolean
return true if specified pump is nitialized.
GetVersionInput: DevVoid
Output: DevString
The firmware version string.
Get the controller firmware version.
GetSizeInput: DevShort
The channel number.
Output: DevString
The pump size
Return the pump size.
GetControlTypeInput: DevVoid
Output: DevString
The controller control type
Read the type of control of the controller ("remote" or "local").
GetChannelStatusInput: DevShort
The channel number
Output: DevString
Get the status of the considered channel.
GetChannelStateInput: DevShort
The channel number
Output: State
Get the considered channel state ("ON" or "OFF").
ChangeSetpointInput: DevVarFloatArray
argin[0] = channel number coded as a float.\nargin[1] = setpoint value.\nargin[2] = 1 for first step current - 2 for second step current.
Output: DevVoid
Change the setpoint of specified channel, and specified current
AddPumpInput: DevShort
Channel number
Output: DevVoid
Add a pump to be controlled.\nThe controller thread will initialize the specified pump and then control it.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.

Pipes:

Properties:

Name Description
SerialDeviceNameDevString The name of the associated serial line device.

Jan. 19, 2017, Piotr Goryl
Edit:
The device server has been updated.
You can see previous version here .



Jan. 3, 2017, Piotr Goryl
Add:
The device server has been added to catalogue.
Added by:pgoryl2 on:3 Jan 2017, 3:15 p.m.