This is historical information of device classes implemented in ABS300 device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/ABS300
Contact:



Class Description


Server to control ABS300 Precision attenuator

Families: BeamlineComponents

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: www.adc9001.com

Product:

www.adc9001.com/products/view/637

Bus: Modbus

Class interface


Attributes:

Name Description
PositionScalar: DevULong
AttenuationScalar: DevDouble
UseOnlyScalar: DevString If you set this to any of the blade materials (e.g. Al), only blades with this material will be used when setting up the desired attenuation. Special value `any` sets the use of all blades. If you want to put in more than one material, separate names by `;` or ','.
NextUpperScalar: DevDouble
NextLowerScalar: DevDouble
SlidersInSpectrum: DevBoolean Spectrum of thenumber of sliders in the system)telling which sliders are in the IN position. Only read.
SetInSpectrum: DevLong Spectrum of number of sliders in the system. for selecting the sliders that should be put in (they will be only move after executing the Move command). The read value indicates the sliders currently selected. 0 = not moved in 1 = moved in
SlidersOutSpectrum: DevBoolean Spectrum of thenumber of sliders in the system)telling which sliders are in the OUT position. Only read.

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
MoveInput: DevVoid
Output: DevVoid
Move to the in position the sliders set in the SetIn attribute.

Pipes:

Properties:

Name Description
HostNameDevString Hostname/IP address of device
PortNumberDevUShort Portnumber of device
NumberOfSlidesDevUShort
DynAttrListArray of DevString for internal use only
GaugesArray of DevDouble The gauge / thickness of the single slides, one per line in µ.
KeepAlivePollDevUShort The PAC CPU ( = the controller ) closes the conection after approx. 30 secs of no activity on the TCP connction. To avoid this a thread is running which request the state of Slide01 every KeepAlivePoll secs. Decrease this value if you experience connection losses.
InvertIOLogicDevBoolean Depending on the assembly position (upside down or not) it might be necessary to invert the logic of true ( = slide in) and false ( = slide out). If this is set to true, the logic will be inverted.
XrayLibDeviceDevString Device name of xraylib server
EnergyAttributeDevString Attribute name where we can get the beam energy, e.g: petra/globals/keyword/Energy
MaterialsArray of DevString Atomic number of material the slides are made of, one per line
SimulationModeDevBoolean

30 Apr 2022, DS Admin
Updated:
A device class has been added.
You can see previous version here .



30 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Nov 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Apr 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:30 a.m.