Average: 0
Rating Count: 0

Development status: Released, Release: Release_1_9
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/ABS300
Contact:



Class Description


Server to control ABS300 Precision attenuator

Families: BeamlineComponents

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: www.adc9001.com

Product:

www.adc9001.com/products/view/637

Bus: Modbus

Class interface


Attributes:

Name Description
SlidersOutSpectrum: DevBoolean Spectrum of thenumber of sliders in the system)telling which sliders are in the OUT position. Only read.
SetInSpectrum: DevLong Spectrum of number of sliders in the system. for selecting the sliders that should be put in (they will be only move after executing the Move command). The read value indicates the sliders currently selected. 0 = not moved in 1 = moved in
SlidersInSpectrum: DevBoolean Spectrum of thenumber of sliders in the system)telling which sliders are in the IN position. Only read.
NextLowerScalar: DevDouble
NextUpperScalar: DevDouble
UseOnlyScalar: DevString If you set this to any of the blade materials (e.g. Al), only blades with this material will be used when setting up the desired attenuation. Special value `any` sets the use of all blades. If you want to put in more than one material, separate names by `;` or ','.
AttenuationScalar: DevDouble
PositionScalar: DevULong

Commands:

Name Description
MoveInput: DevVoid
Output: DevVoid
Move to the in position the sliders set in the SetIn attribute.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.

Pipes:

Properties:

Name Description
SimulationModeDevBoolean
MaterialsArray of DevString Atomic number of material the slides are made of, one per line
EnergyAttributeDevString Attribute name where we can get the beam energy, e.g: petra/globals/keyword/Energy
XrayLibDeviceDevString Device name of xraylib server
InvertIOLogicDevBoolean Depending on the assembly position (upside down or not) it might be necessary to invert the logic of true ( = slide in) and false ( = slide out). If this is set to true, the logic will be inverted.
KeepAlivePollDevUShort The PAC CPU ( = the controller ) closes the connection after approx. 30 secs of no activity on the TCP connction. To avoid this a thread is running which request the state of Slide01 every KeepAlivePoll secs. Decrease this value if you experience connection losses.
GaugesArray of DevDouble The gauge / thickness of the single slides, one per line in µ.
DynAttrListArray of DevString for internal use only
NumberOfSlidesDevUShort
PortNumberDevUShort Portnumber of device
HostNameDevString Hostname/IP address of device


Please log in to comment.

Nov. 17, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



April 28, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



Feb. 23, 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



Jan. 19, 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



Jan. 2, 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:2 Jan 2017, 3:47 p.m.