This is historical information of device classes implemented in Lambda device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


This is a tango server project for lambda detetor.

Families: Acquisition

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: DESY(FS-DS)

Bus: Ethernet

Class interface


Attributes:

Name Description
TriggerModeScalar: DevShort TriggerMode of the Detector.
ShutterTimeScalar: DevDouble shutter time
DelayTimeScalar: DevDouble delay time, currently it is not used
FrameNumbersScalar: DevLong The frame numbers need to be acquired.
BurstModeScalar: DevBoolean burst mode 1: 10GE links 0: 1GE links
ThreadNoScalar: DevLong
ThresholdEnergyScalar: DevFloat
OperatingModeScalar: DevString operating mode of the detector: 24bit mode : TwentyFourBit 12bit mode :ContinuousReadWrite
SaveAllImagesScalar: DevBoolean this attribute is not used now
ConfigFilePathScalar: DevString Path of the configuration file.
SaveFilePathScalar: DevString Save File Path. Define path for saving files.
LatestImageNumberScalar: DevLong The frame number of latest image
SaveFileNameScalar: DevString define the file name for saving file.
ImageScalar: DevEncoded provide data interface for online visualization
LiveModeScalar: DevBoolean live mode of the detector. Mainly used for online visualization. True: enable online visulization, frame rate is limited to 10fps. The data will not be saved to disk. The data can be fetched by accessing attribute Image False: diasble online visualization.
TotalLossFramesScalar: DevLong the total frame numbers lost during transmitting, used in 10GE linke mode.
CompressorShuffleScalar: DevBoolean during compression, shuffle the data or not
CompressionRateScalar: DevUShort set compression rate from 0-9
CompressionEnabledScalar: DevBoolean applying compression to data when saving. True: compression False: no compression
LayoutScalar: DevString The layout out of Chips. 1 : 1536x512 pixels 2 : 768x512 pixels
ShutterTimeMaxScalar: DevDouble define the maximum shutter time(only for expert view).
ShutterTimeMinScalar: DevDouble define the minimum shutter time(only for expert view).

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAcqInput: DevVoid
Output: DevVoid
Start the acquisition.
StopAcqInput: DevVoid
Output: DevVoid
stop the acquistion

Pipes:

Properties:

Name Description
SimulationModeDevUShort Providing simulation mode for the detector

Dec. 8, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



Oct. 27, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



Sept. 15, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



Aug. 4, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



April 28, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



March 10, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



Jan. 5, 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



Sept. 30, 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



Feb. 23, 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



Jan. 19, 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



Jan. 2, 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 11:33 a.m.